• Dranetz HDPQ® Guide Portable and

    HDPQ Guide SP (Rated IP65) Power Quality Analyzers

    The Best Combination Of Value and Technology In a Power Quality Analyzer – Safe, Powerful, & Intelligent

    Power from the Phase Feature; Power the Instrument from the Circuit Being Measured, or Another Source (SP Only)

    Dranetz HDPQ Guide - Guide SP

     

    Tests 16/25Hz and 50/60Hz

    Powered by the Phase Being Measured!
    (SP Only)

    Remote Wi-Fi Communications

    AnswerModules® Included

    GPS Optional (Factory installed only on SP)

    Made in the USA

    Dranetz HDPQ SP Power From the Phase

     

    The Dranetz HDPQ Guide (Portable) and Dranetz HDPQ Guide SP (IP65) power quality analyzers offer the best combination of value & technology from Dranetz, or any other PQ analyzer available! It includes all of the features of the Dranetz HDPQ Visa instruments, but adds Wi-Fi communications, AnswerModules®, and a 10,000 cycle recording buffer for fault and inrush recording!

    The Dranetz HDPQ Guide and Dranetz HDPQ Guide SP are the exact same instrument, but are in different enclosures. The Dranetz HDPQ Guide is a true hand-held portable instrument with a built in 7″, tablet-like touch LCD display. The Dranetz HDPQ Guide SP has the same measurement and communications capabilities, but is housed in an IP65 enclosure without an LCD display, and can also be powered by the circuit being measured. The IP65 enclosure of the Dranetz HDPQ Guide SP greatly expands the applications of the Dranetz HDPQ Guide into outdoor and harsh environments, along with other applications where an LCD display is undesirable.

    The Dranetz HDPQ Guide and Dranetz HDPQ Guide SP Power Quality Analyzers provides you the best in class power quality monitoring capabilities available. They measure to all current industry standards, including IEC 61000-4-30 Class A, IEC 61000-4-7, IEEE 1159, IEEE 519, IEEE 1459, and more. Equipped with 8 independent channels, automated setups provide instant detection of circuits and configurations, ensuring that the instrument is ready to successfully collect data in seconds. Users can select the length and mode of data collection, including troubleshooting, data logging, power quality surveys, energy, and load balancing. The Intelligent AnswerModule® feature provides consultant-like analysis of sag directivity, capacitor switching transient identification/directivity, and motor analysis/reporting.

    The Dranetz HDPQ Guide and Dranetz HDPQ Guide SP enable users to review data and change settings remotely from virtually any smartphone, tablet and mobile device, as well as with traditional PC and MAC laptops and desktops. Just hook up the instrument, close the cabinets to the ‘safe’ environment, and use either the VNC interface along with our Dran-View 7 software, or our Dranetz HDPQ Apple or Android Apps via Ethernet or W-Fi for remote control from anywhere with connectivity to the instrument.

    Dranetz HDPQ Guide & HDPQ Guide SP – Precision


    • High Definition Power Quality & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle
    • Eight channels, 4 voltage & 4 current
    • AnswerModules – Sag directivity, PF capacitor identification, motor – automatic event categorization
    • Advanced PQ – IEC 61000-4-30 Class A & IEEE 1159 compliant
    • Harmonics – IEC 61000-4-7, IEEE 519 (2014)
    • Transient capabilities – V & I – waveshape triggers. Well beyond standards requirements
    • IEEE 1459 Advanced Power Measurements
    • 10,000 cycle pre/post trigger buffer
    • EN 50160 Ed 3

    Dranetz HDPQ Guide & HDPQ Guide SP – Communications

    • Ethernet, Wi-Fi, USB, Bluetooth
    • VNC for full remote control from Dran-View 7 or a 3rd party App
    • Apple & Android apps with real time metering and alarm Dashboard

    Dranetz HDPQ Guide & HDPQ Guide SP – Safe & Rugged

    • Arc Flash Safety
    • UL/cUL listed and CE approved
    • Rugged enclosure with an easy to grip, shock absorbing, non-conductive boot (Dranetz HDPQ Guide only)
    • IP65 enclosure for harsh and outdoor environments (Dranetz HDPQ Guide SP only)
    • Drop tested to 6’ (Dranetz HDPQ Guide only)
    • Power supply cable retainer (Dranetz HDPQ Guide only)
    • Wire management in easel and hook (Dranetz HDPQ Guide only)
    • Automatic circuit detection and feedback on proper connection of the instrument User Interface

    Dranetz HDPQ Guide & HDPQ Guide SP – User Interface 

    • 7” WVGA color touch display (Dranetz HDPQ Guide only)
    • Automatic setups – PQ, Demand and Energy
    • Tablet-like GUI that is icon driven, has taskbar shortcuts, and a Dashboard (only available remotely on the Dranetz HDPQ Guide SP)

    Dranetz HDPQ Guide & HDPQ Guide SP – Productivity

    • Mini-report – Screen snapshots, XML file. Easily uploaded and emailed!
    • PQ & Energy Dashboard’s for real time alarming
    • Bigger display for more productive local analysis (Dranetz HDPQ Guide only)
    • AnswerModules – automatic event categorization
    Dran-View 7 power quality analysis software
    • Rescue kit – Part of Dran-View 7. Correct problems with wiring, CT orientation, time errors and more
    • Post processing – Part of Dran-View 7. Compute harmonics and other parameters from the waveforms recorded by the instrument

     

    Dranetz HDPQ Guide & HDPQ Guide SP – Measured Parameters

    (4) Differential Voltage: 16 bit resolution

    • 0-1000Vrms, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • IEC 61000-4-30 Class A: 60-1000Vrms, ±0.1 % of Udin, range of 10% – 150% of Udin
    • Transients – rms: 0-1414Vpk, ±0.2 % of Udin

    (4) Current: 512 s/c, 16 bit resolution

    • Range (rms) probe dependent, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • Transients – Range probe dependent

    Frequency: 10 sec window
    16-25Hz, 42.5-69Hz, +/- 0.01Hz

    Calculated Parameters

    Power/Energy – 1 Second sampling
    Real Power (W) – P: meets 0.2S requirements, range probe dep.
    Apparent Power (VA) – S: meets 0.2S requirements, range probe dep.
    Reactive Power (var) – Q: meets 0.2S requirements, range probe dep.
    Power Factor (W/VA) -”true” -1 to 0 to 1
    Displacement PF -1 to 0 to 1
    Demand (in W): meets 0.2S requirements, range probe dep.
    Energy (in Wh): meets 0.2S requirements, range probe dep.

    Distortion – 200ms, 3 sec, 10 min windows
    Vthd: 0-100%, +/- 5% for V>=1% Vnom,
    V Ind Harm: DC, 2-127, +/- 5% for V>=10% Vnom
    Ithd: 0-100%, +/- 5% for I>=1% Inom,
    I Ind Harm: DC, 2-63, +/- 5% for I>=10% Inom

    Misc.
    Pst – 10 minutes: 0.2-10, +/- 0.05 @ Pst=1
    Plt – 2 hours: 0.2-10, +/- 0.05 @ Pst=1

    Standards Compliance

    Power Quality
    IEC 61000-4-30 Class A: Edition 2 (2008)
    IEEE 1159: 2009

    Power
    IEEE 1459: 2000

    Harmonics
    IEC 61000-4-7 Class 1: Edition 2 (2008)
    IEEE 519: 2014

    Voltage Flicker
    IEC 61000-4-15: Edition 2 (2010)
    IEEE 1453: 2011

    Compliance/Testing
    EN 50160: 2010

    General Specifications (Dranetz HDPQ Guide and HDPQ Guide SP unless otherwise noted)

    Dranetz HDPQ Guide

    • Size: (10″w x 8″h x 2.75″d), (25.4cm x 20.3cm x 7.0cm)
    • Weight: 4.2lbs, 2kg
    • Operating temperature: 0 to 50 deg C (32 to 122 deg F)
    • Storage temperature: -20 to 55 deg C (-4 to 131 deg F)
    • Humidity: 10-90% non condensing

    Dranetz HDPQ Guide SP (IP65)

    • Size: (11″w x 6.5″h x 2.5″d), (27.9cm x 16.5cm x 6.4cm)
    • Weight: 3.8lbs, 1.72kg
    • Operating temperature: -10 to 50 deg C (14 to 122 deg F)
    • Storage temperature: -40 to 85 deg C (-40 to 185 deg F)
    • Humidity: 10-90% non condensing
    • Power Supply: 90-600VAC/500VDC (50/60Hz). Powered by the phase being measured, or other source

    Clock accuracy and resolution

    • Internal: +/- 1 sec/day at 25 deg C
    • NTP: +/-10 msec
    • GPS: +/-1 msec

    AC Adapter: 100-240Vac 50/60Hz
    Battery capacity and charge time:

    • Dranetz HDPQ Guide: 3 hours run time on full charge, 3 hours charge time
    • Dranetz HDPQ Guide SP: 30 minutes run time on full charge, 3 hours charge time

    Memory size: 4GB
    Display: 7” WVGA color graphic, Icon based touch LCD, LED Backlit (Dranetz HDPQ Guide only)
    Languages: English, German, Spanish, French, Italian, Swedish, Finnish, Polish, Chinese (traditional and simplified), Thai, Korean

    Communications

    Ethernet, 802.11 b/g/n Wireless (available without Wi-Fi as a special order)
    USB On The Go (OTG)
    Bluetooth via USB adapter
    VNC remote control
    Android & Apple App

    Ease of Use Features

    Automatic Setups – Start monitoring in seconds!
    Pre-programmed monitoring modes – Pre-configured setups for various applications
    AnswerModules®– Sag/Dip directivity, PF Cap, Motor Health
    Dashboards – Power Quality, Demand & Energy – Immediately know when events have been recorded
    Simultaneous Power Quality, Demand & Energy monitoring
    Mini-Report – Take screen snapshots that can be uploaded to your computer and included in reports, attached to emails, etc.

    Power the instrument from the circuit being measured, or another source (SP Only)

    Click here for Brochure - Dranetz - HDPQ Guide 

     

    02 9659 2300

    Quantity
{
  "moduleName": "overallcatalog",
  "name": "Power and Utilities",
  "id": 312399,
  "description": "",
  "pagination": {
    "currentPage": 1,
    "itemsPerPage": 12,
    "numberOfPages": 0,
    "totalItemsCount": 0,
    "previousPageUrl": null,
    "nextPageUrl": null
  },
  "globals": {
    "get": {
      "CatalogueID": "312399",
      "ProductID": "10382090"
    },
    "cookie": {
      "visitorDeviceClass": "desktop",
      "ASP.NET_SessionId": "ak10mfmfhnk0ssmwt0pefslm",
      "ANONID_FS2805306": "19.08.2019 16:15:34.600",
      "ANONID2805306": "a3d12cf6-a183-43aa-8416-0d724f09aed1",
      "VISID2805306": "845a879b-0236-4450-9622-74fae9e43e3d#www.pacifictest.com.au#19.08.2019 16:15:34.600"
    },
    "site": {
      "id": 2805306,
      "name": "Pacific Test Equipment",
      "host": "www.pacifictest.com.au",
      "countryCode": "AU",
      "language": "EN",
      "dateNow": "2019-08-20T02:15:34.6319766"
    },
    "visitor": {
      "deviceClass": "desktop",
      "ip": "162.158.79.119",
      "country": "US",
      "city": "Ashburn",
      "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)",
      "referrer": "/"
    },
    "cart": {
      "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=312399"
    },
    "user": {
      "entityId": 0,
      "firstname": "",
      "middleName": "",
      "lastname": "",
      "fullname": "",
      "username": "",
      "email": "",
      "email2": "",
      "email3": "",
      "customerType": {},
      "leadSourceType": {},
      "industryType": {},
      "ratingType": {},
      "isWholesaler": false,
      "isLoggedIn": false
    }
  },
  "tag_productlist_5_6": {
    "moduleName": "tag_productlist_5",
    "moduleDescriptor": {
      "templatePath": "/Layouts/OnlineShop/large_product.html",
      "parameters": "3,,8,,true,true",
      "apiEndpoint": "/webresources/api/v3/sites/2805306/products",
      "objectType": -1,
      "objectId": 10382090,
      "adminUrl": ""
    },
    "editableFieldTypes": {
      "description": "Html",
      "id": "Id",
      "name": "Text",
      "url": "Text",
      "title": "Text",
      "smallImage": "Image",
      "largeImage": "Image",
      "releaseDate": "Date",
      "expiryDate": "Date",
      "productCode": "Text",
      "inStock": "Number",
      "onOrder": "Number",
      "reorder": "Number",
      "minUnits": "Number",
      "maxUnits": "Number",
      "unitType": "Text",
      "tags": "Text",
      "custom1": "Text",
      "custom2": "Text",
      "custom3": "Text",
      "custom4": "Text",
      "isOnSale": "Boolean",
      "retailPrice": "Number",
      "salePrice": "Number",
      "wholesalePrice": "Number",
      "metaTitle": "Text",
      "metaDescription": "Text"
    },
    "description": "

Dranetz HDPQ® Guide Portable and

\n

HDPQ Guide SP (Rated IP65) Power Quality Analyzers

\n

The Best Combination Of Value and Technology In a Power Quality Analyzer – Safe, Powerful, & Intelligent\n
\n

\n

Power from the Phase Feature; Power the Instrument from the Circuit Being Measured, or Another Source (SP Only)

\n
\n
\n \"Dranetz \n

 

\n
\n

Tests 16/25Hz and 50/60Hz

\n

Powered by the Phase Being Measured!
(SP Only)

\n

Remote Wi-Fi Communications

\n

AnswerModules® Included

\n

GPS Optional (Factory installed only on SP)

\n

Made in the USA

\n
\n
\n \"Dranetz \n

 

\n

The Dranetz HDPQ Guide (Portable) and Dranetz HDPQ Guide SP (IP65) power quality analyzers offer the best combination of value & technology from\n Dranetz, or any other PQ analyzer available! It includes all of the features of the Dranetz HDPQ Visa instruments, but adds Wi-Fi communications, AnswerModules®,\n and a 10,000 cycle recording buffer for fault and inrush recording!

\n

The Dranetz HDPQ Guide and Dranetz HDPQ Guide SP are the exact same instrument, but are in different enclosures. The Dranetz HDPQ Guide is a true hand-held\n portable instrument with a built in 7″, tablet-like touch LCD display. The Dranetz HDPQ Guide SP has the same measurement and communications capabilities,\n but is housed in an IP65 enclosure without an LCD display, and can also be powered by the circuit being measured. The IP65 enclosure of the Dranetz\n HDPQ Guide SP greatly expands the applications of the Dranetz HDPQ Guide into outdoor and harsh environments, along with other applications where\n an LCD display is undesirable.

\n

The Dranetz HDPQ Guide and Dranetz HDPQ Guide SP Power Quality Analyzers provides you the best in class power quality monitoring capabilities available.\n They measure to all current industry standards, including IEC 61000-4-30 Class A, IEC 61000-4-7, IEEE 1159, IEEE 519, IEEE 1459, and more. Equipped\n with 8 independent channels, automated setups provide instant detection of circuits and configurations, ensuring that the instrument is ready to\n successfully collect data in seconds. Users can select the length and mode of data collection, including troubleshooting, data logging, power quality\n surveys, energy, and load balancing. The Intelligent AnswerModule® feature provides consultant-like analysis of sag directivity, capacitor switching transient identification/directivity, and motor analysis/reporting.

\n

The Dranetz HDPQ Guide and Dranetz HDPQ Guide SP enable users to review data and change settings remotely from virtually any smartphone, tablet and\n mobile device, as well as with traditional PC and MAC laptops and desktops. Just hook up the instrument, close the cabinets to the ‘safe’ environment,\n and use either the VNC interface along with our Dran-View 7 software, or our Dranetz HDPQ Apple or Android Apps via Ethernet or W-Fi for remote\n control from anywhere with connectivity to the instrument.

\n

Dranetz HDPQ Guide & HDPQ Guide SP – Precision\n

\n
• High Definition Power Quality & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle \n
• Eight channels, 4 voltage & 4 current \n
• AnswerModules – Sag directivity, PF capacitor identification, motor – automatic event categorization \n
• Advanced PQ – IEC 61000-4-30 Class A & IEEE 1159 compliant \n
• Harmonics – IEC 61000-4-7, IEEE 519 (2014) \n
• Transient capabilities – V & I – waveshape triggers. Well beyond standards requirements \n
• IEEE 1459 Advanced Power Measurements \n
• 10,000 cycle pre/post trigger buffer \n
• EN 50160 Ed 3 \n

Dranetz HDPQ Guide & HDPQ Guide SP – Communications

\n

• Ethernet, Wi-Fi, USB, Bluetooth \n
• VNC for full remote control from Dran-View 7 or a 3rd party App \n
• Apple & Android apps with real time metering and alarm Dashboard

\n

Dranetz HDPQ Guide & HDPQ Guide SP – Safe & Rugged

• Arc Flash Safety \n
• UL/cUL listed and CE approved \n
• Rugged enclosure with an easy to grip, shock absorbing, non-conductive boot (Dranetz HDPQ Guide only) \n
• IP65 enclosure for harsh and outdoor environments (Dranetz HDPQ Guide SP only) \n
• Drop tested to 6’ (Dranetz HDPQ Guide only) \n
• Power supply cable retainer (Dranetz HDPQ Guide only) \n
• Wire management in easel and hook (Dranetz HDPQ Guide only) \n
• Automatic circuit detection and feedback on proper connection of the instrument User Interface \n

Dranetz HDPQ Guide & HDPQ Guide SP – User Interface 

\n • 7” WVGA color touch display (Dranetz HDPQ Guide only) \n
• Automatic setups – PQ, Demand and Energy \n
• Tablet-like GUI that is icon driven, has taskbar shortcuts, and a Dashboard (only available remotely on the Dranetz HDPQ Guide SP)\n

Dranetz HDPQ Guide & HDPQ Guide SP – Productivity

• Mini-report – Screen snapshots, XML file. Easily uploaded and emailed! \n
• PQ & Energy Dashboard’s for real time alarming \n
• Bigger display for more productive local analysis (Dranetz HDPQ Guide only) \n
• AnswerModules – automatic event categorization \n
Dran-View 7 power quality analysis software \n
• Rescue kit – Part of Dran-View 7. Correct problems with wiring, CT orientation, time errors and more \n
• Post processing – Part of Dran-View 7. Compute harmonics and other parameters from the waveforms recorded by the instrument\n

 

\n

Dranetz HDPQ Guide & HDPQ Guide SP – Measured Parameters

\n

(4) Differential Voltage: 16 bit resolution

\n
    \n
  • 0-1000Vrms, AC/DC, +/- 0.1% reading +/- 0.05% FS
  • \n
  • IEC 61000-4-30 Class A: 60-1000Vrms, ±0.1 % of Udin, range of 10% – 150% of Udin
  • \n
  • Transients – rms: 0-1414Vpk, ±0.2 % of Udin
  • \n
\n

(4) Current: 512 s/c, 16 bit resolution

\n
    \n
  • Range (rms) probe dependent, AC/DC, +/- 0.1% reading +/- 0.05% FS
  • \n
  • Transients – Range probe dependent
  • \n
\n

Frequency: 10 sec window\n
16-25Hz, 42.5-69Hz, +/- 0.01Hz

\n

Calculated Parameters

\n

Power/Energy – 1 Second sampling\n
Real Power (W) – P: meets 0.2S requirements, range probe dep.\n
Apparent Power (VA) – S: meets 0.2S requirements, range probe dep.\n
Reactive Power (var) – Q: meets 0.2S requirements, range probe dep.\n
Power Factor (W/VA) -”true” -1 to 0 to 1\n
Displacement PF -1 to 0 to 1\n
Demand (in W): meets 0.2S requirements, range probe dep.\n
Energy (in Wh): meets 0.2S requirements, range probe dep.

\n

Distortion – 200ms, 3 sec, 10 min windows\n
Vthd: 0-100%, +/- 5% for V>=1% Vnom,\n
V Ind Harm: DC, 2-127, +/- 5% for V>=10% Vnom\n
Ithd: 0-100%, +/- 5% for I>=1% Inom,\n
I Ind Harm: DC, 2-63, +/- 5% for I>=10% Inom

\n

Misc.\n
Pst – 10 minutes: 0.2-10, +/- 0.05 @ Pst=1\n
Plt – 2 hours: 0.2-10, +/- 0.05 @ Pst=1

\n

Standards Compliance

\n

Power Quality\n
IEC 61000-4-30 Class A: Edition 2 (2008)\n
IEEE 1159: 2009

\n

Power\n
IEEE 1459: 2000

\n

Harmonics\n
IEC 61000-4-7 Class 1: Edition 2 (2008)\n
IEEE 519: 2014

\n

Voltage Flicker\n
IEC 61000-4-15: Edition 2 (2010)\n
IEEE 1453: 2011

\n

Compliance/Testing\n
EN 50160: 2010

\n

General Specifications (Dranetz HDPQ Guide and HDPQ Guide SP unless otherwise noted)

\n

Dranetz HDPQ Guide

\n
    \n
  • Size: (10″w x 8″h x 2.75″d), (25.4cm x 20.3cm x 7.0cm)
  • \n
  • Weight: 4.2lbs, 2kg
  • \n
  • Operating temperature: 0 to 50 deg C (32 to 122 deg F)
  • \n
  • Storage temperature: -20 to 55 deg C (-4 to 131 deg F)
  • \n
  • Humidity: 10-90% non condensing
  • \n
\n

Dranetz HDPQ Guide SP (IP65)

\n
    \n
  • Size: (11″w x 6.5″h x 2.5″d), (27.9cm x 16.5cm x 6.4cm)
  • \n
  • Weight: 3.8lbs, 1.72kg
  • \n
  • Operating temperature: -10 to 50 deg C (14 to 122 deg F)
  • \n
  • Storage temperature: -40 to 85 deg C (-40 to 185 deg F)
  • \n
  • Humidity: 10-90% non condensing
  • \n
  • Power Supply: 90-600VAC/500VDC (50/60Hz). Powered by the phase being measured, or other source
  • \n
\n

Clock accuracy and resolution

\n
    \n
  • Internal: +/- 1 sec/day at 25 deg C
  • \n
  • NTP: +/-10 msec
  • \n
  • GPS: +/-1 msec
  • \n
\n

AC Adapter: 100-240Vac 50/60Hz\n
Battery capacity and charge time:

\n
    \n
  • Dranetz HDPQ Guide: 3 hours run time on full charge, 3 hours charge time
  • \n
  • Dranetz HDPQ Guide SP: 30 minutes run time on full charge, 3 hours charge time
  • \n
\n

Memory size: 4GB\n
Display: 7” WVGA color graphic, Icon based touch LCD, LED Backlit (Dranetz HDPQ Guide only)\n
Languages: English, German, Spanish, French, Italian, Swedish, Finnish, Polish, Chinese (traditional and simplified), Thai, Korean

\n

Communications

\n

Ethernet, 802.11 b/g/n Wireless (available without Wi-Fi as a special order)\n
USB On The Go (OTG)\n
Bluetooth via USB adapter\n
VNC remote control\n
Android & Apple App

\n

Ease of Use Features

\n

Automatic Setups – Start monitoring in seconds!
Pre-programmed monitoring modes – Pre-configured setups for various applications
AnswerModules®– Sag/Dip directivity, PF Cap, Motor Health
Dashboards – Power Quality, Demand & Energy – Immediately know when events have been recorded
Simultaneous Power Quality, Demand & Energy monitoring
Mini-Report – Take screen snapshots that can be uploaded to your computer and included in reports, attached to emails, etc.

\n

Power the instrument from the circuit being measured, or another source (SP Only)

Click here for Brochure - Dranetz - HDPQ Guide \n
\n

 

\n
", "catalogId": 312399, "id": 10382090, "name": "Dranetz - HDPQ Guide - 10,000 trigger cycles, Sag, PF Correction, Bluetooth, Wifi", "url": "/industries-1/electrical-utility/dranetz-hdpq-guide", "title": "", "smallImage": "/_assets/images/product/HDPQ_Guide.png", "smallImageUrl": "/_assets/images/product/HDPQ_Guide.png", "largeImage": "/_assets/images/product/HDPQ_Guide.png", "largeImageUrl": "/_assets/images/product/HDPQ_Guide.png", "releaseDate": "2016-10-04T00:00:00", "releaseDate_raw": "2016-10-03T23:00:00", "expiryDate": "9999-01-01T00:00:00", "expiryDate_raw": "9999-01-01T00:00:00", "productCode": "HDPQ Guide", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "metaTitle": "", "metaDescription": "", "urlWithHost": "http://www.pacifictest.com.au/industries-1/electrical-utility/dranetz-hdpq-guide", "myPoplets": { "moduleName": "data", "moduleDescriptor": { "templatePath": null, "parameters": "version=\"v3\",resource=\"products\",resourceid=\"10382090\",fields=\"poplets\",collection=\"myPoplets\",template=\"\"", "apiEndpoint": "/api/v3/data", "objectType": -1, "objectId": -1, "adminUrl": "" }, "poplets": "", "params": { "version": "v3", "resource": "products", "resourceid": "10382090", "fields": "poplets", "collection": "myPoplets", "template": "" } }, "tag_addtofavorites_6_7": { "moduleName": "tag_addtofavorites_6", "moduleDescriptor": { "templatePath": null, "parameters": "Add to Wishlist,Remove from Wishlist", "apiEndpoint": "/api/v3/tag_addtofavorites_6", "objectType": -1, "objectId": -1, "adminUrl": "" }, "isFavorite": false, "addUrl": "/FavoriteProcess.aspx?OID=10382090&OTYPE=27", "addText": "Add to Wishlist", "removeUrl": "/FavoriteProcess.aspx?A=Remove&OID=10382090&OTYPE=27", "removeText": "Remove from Wishlist", "full": "Add to Wishlist" }, "relatedProducts": { "moduleName": "tag_relatedproducts_8", "moduleDescriptor": { "templatePath": "/Layouts/OnlineShop/small_product.html", "parameters": ",template=\"\",collection=\"relatedProducts\"", "apiEndpoint": "/api/v3/tag_relatedproducts_8", "objectType": -1, "objectId": -1, "adminUrl": "" } } } }
No items found.