• Dranetz - HDPQ VISA - 100 trigger cycles, Sag/Dip, Swell Transient, Harmonics

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
    \n

    Dranetz HDPQ® Visa Portable 

    \n

    The Best Value in Power Quality Monitoring

    \n

    Power from the Phase Feature; Power the Instrument from the Circuit Being Measured, or Another Source (SP Only)

    \n
    \n
    \n \"Dranetz \n

     

    \n
    \n

     \n

    \n

    Tests 16/25Hz and 50/60Hz\n

    \n

    Wired Ethernet Communications\n
    \n

    \n

    Bluetooth Optional\n

    \n

    GPS Optional
     \n

    \n

    Made in the USA \n

    \n
    \n
    \n

    The Dranetz HDPQ® Visa (Portable) power quality analyzers offer the best value in power quality, demand, and energy monitoring from Dranetz, or\n any other Power Quality analyzer manufacturer! No other product at this price point comes close to matching the benefits and features provided\n by the Dranetz HDPQ Visa family of products.\n

    \n
    \n
    \n
    \n

    The Dranetz HDPQ Visa is a true hand-held portable instrument with a built in 7″, tablet-like touch LCD display. 

    \n

    The Dranetz HDPQ Visa enables users to review data and change settings remotely from virtually any smartphone, tablet and mobile device, as well as\n with traditional PC and MAC laptops and desktops. Just hook up the instrument, close the cabinets to the ‘safe’ environment, and use either the\n VNC interface along with our Dran-View 7 software, or our Dranetz HDPQ Apple or Android Apps via Ethernet for remote control from anywhere with\n connectivity to the instrument.

    \n
    \n

    Dranetz HDPQ Visa  Precision

    • High Definition PQ & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle\n
    • Eight channels, 4 voltage & 4 current\n
    • Advanced PQ – IEC 61000-4-30 Class A & IEEE 1159 compliant\n
    • Harmonics – IEC 61000-4-7, IEEE 519 (2014)\n
    • Transient capabilities – V & I waveshape triggers. Well beyond standards requirements\n
    • 100 cycle pre/post trigger buffer\n
    • EN 50160 Ed 3\n
    • Motor AnswerModule®\n

    Dranetz HDPQ Visa  – Communications

    • Ethernet, USB, Bluetooth – Optional\n
    • VNC for full remote control from Dran-View 7 or a 3rd party App\n
    • Apple & Android apps with real time metering and alarm Dashboard\n

    Dranetz HDPQ Visa  – Safe & Rugged

    • Arc Flash Safety \n
    • UL/cUL listed and CE approved \n
    • Rugged enclosure with an easy to grip, shock absorbing, non-conductive boot \n
    • Power supply cable retainer and wire management \n
    • Drop tested to 6’ \n
    • Automatic circuit detection and feedback on proper connection of the instrument\n

    Dranetz HDPQ Visa – User Interface

    • 7” WVGA color touch display \n
    • Automatic setups – PQ, Demand and Energy \n
    • Tablet-like GUI that is icon driven, has taskbar shortcuts, and a Dashboard \n

    Dranetz HDPQ Visa & HDPQ SP – Productivity

    • Mini-Report – Screen snapshots, XML file. Easily uploaded and emailed!\n
    • PQ & Energy Dashboard’s for real time alarming\n
    • Bigger display for more productive local analysis \n
    Dran-View 7 power quality analysis software\n
    • Rescue kit – Part of Dran-View 7. Correct problems with wiring, CT orientation, time errors and more\n

    • Post processing – Part of Dran-View 7. Compute harmonics and other parameters from the waveforms recorded by the instrument

    \n

     

    \n

    Dranetz HDPQ Visa – Measured Parameters

    \n

    (4) Differential Voltage: 16 bit resolution

    \n
      \n
    • 0-1000Vrms, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • IEC 61000-4-30 Class A: 60-1000Vrms, ±0.1 % of Udin, range of 10% ~ 150% of Udin
    • \n
    • Transients – 0-1414Vpk, +/- .2% of Udin
    • \n
    \n

    (4) Current: 512 samples/cycle, 16 bit resolution

    \n
      \n
    • Range (rms) probe dependent, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • Transients – Range probe dependent
    • \n
    \n

    Frequency: 10 sec window

    \n
      \n
    • 16-25Hz, 42.5-69Hz, +/- 0.01Hz
    • \n
    \n

    Calculated Parameters

    \n

    Power/Energy – 1 Second sampling\n
    Real Power (W) – P: meets 0.2S requirements, range probe dependent\n
    Apparent Power (VA) – S: meets 0.2S requirements, range probe dependent\n
    Reactive Power (var) – Q: meets 0.2S requirements, range probe dependent\n
    Power Factor (W/VA) -”true” -1 to 0 to 1\n
    Displacement PF -1 to 0 to 1\n
    Demand (in W): meets 0.2S requirements, range probe dependent\n
    Energy (in Wh): meets 0.2S requirements, range probe dependent

    \n

    Distortion – 200ms, 3 sec, 10 min windows\n
    Vthd: 0-100%, +/- 5% for V>=1% Vnom,\n
    V Ind Harm: DC, 2-127, +/- 5% for V>=1% Vnom\n
    Ithd: 0-100%, +/- 5% for I>=1% Inom,\n
    I Ind Harm: DC, 2-63, +/- 5% for I>=1% Inom

    \n

    Misc.\n
    Pst – 10 minutes: 0.2-10, +/- 0.05 @ Pst=1\n
    Plt – 2 hours: 0.2-10, +/- 0.05 @ Pst=1

    \n

    Standards Compliance

    \n

    Power Quality\n
    IEC 61000-4-30 Class A: Edition 2 (2008)\n
    IEEE 1159: 2009

    \n

    Power\n
    IEEE 1459: 2000

    \n

    Harmonics\n
    IEC 61000-4-7 Class 1: Edition 2 (2008)\n
    IEEE 519: 2014

    \n

    Voltage Flicker\n
    IEC 61000-4-15: Edition 2 (2010)\n
    IEEE 1453: 2011

    \n

    Compliance/Testing\n
    EN 50160: 2010

    \n

    General Specifications 

    \n

    Dranetz HDPQ Visa

    \n
      \n
    • Size: (10″w x 8″h x 2.75″d), (25.4cm x 20.3cm x 7.0cm)
    • \n
    • Weight: 4.2lbs, 2kg
    • \n
    • Operating temperature: 0 to 50 deg C ( 32 to 122 deg F)
    • \n
    • Storage temperature: -20 to 60 deg C (-4 to 131 deg F)
    • \n
    • Humidity: 10-90% non condensing
    • \n
    • AC Adapter (12V): 100-240Vac 50/60Hz
    • \n
    \n

    Clock accuracy and resolution\n
    \n

    \n
      \n
    • Internal: +/- 1 sec/day at 25 deg C
    • \n
    • NTP: +/-10 msec
    • \n
    • GPS: +/-1 msec
    • \n
    \n

    Battery capacity and charge time:

    \n
      \n
    • Dranetz HDPQ Visa: 3 hours run time on full charge, 3 hours charge time
    • \n
    \n

    Memory size: 4GB\n
    Display: 7” WVGA color graphic, Icon based touch LCD, LED Backlit \n
    \n
    \n

    \n

    Communications

    \n

    Ethernet\n
    Bluetooth (optional)\n
    USB On the Go (OTG)\n
    VNC remote control\n
    Android & Apple Apps

    \n

    Ease of Use Features

    \n

    Automatic Setups – Start monitoring in seconds!\n
    Pre-programmed monitoring modes – Pre-configured setups for various applications\n
    Dashboards – Power Quality, Demand & Energy – Immediately know when events have been recorded\n
    Simultaneous Power Quality, Demand & Energy monitoring\n
    Mini-Report – Take screen snapshots that can be uploaded to your computer and included in reports, attached to emails, etc.\n
    Power the instrument from the circuit being measured, or another source (SP Only)

    Brochure - Dranetz - HDPQ VISA \n
    \n

     

    \n

     

    ", "catalogId": 312399, "id": 10382087, "name": "Dranetz - HDPQ VISA - 100 trigger cycles, Sag/Dip, Swell Transient, Harmonics", "url": "/industries-1/electrical-utility/dranetz-hdpq-visa", "title": "", "smallImage": "/_assets/images/product/HDPQ_Visa.png", "smallImageUrl": "/_assets/images/product/HDPQ_Visa.png", "largeImage": "/_assets/images/product/HDPQ_Visa.png", "largeImageUrl": "/_assets/images/product/HDPQ_Visa.png", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "HDPQ VISA", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/industries-1/electrical-utility/dranetz-hdpq-visa", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Guide - 10,000 trigger cycles, AnswerModules, Sag/Dip, Swell Transient, Harmonics

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "

    Dranetz HDPQ® Guide Portable Power Quality Analyzers

    \n

    The Best Combination Of Value and Technology In a Power Quality Analyzer – Safe, Powerful, & Intelligent\n
    \n

    \n

    Tests 16/25Hz and 50/60Hz

    \n
    \n

    Remote Wi-Fi Communications\n

    \n

    AnswerModules® Included

    \n

    GPS Optional 

    \n

    Made in the USA

    \n
    \n
    \n

    The Dranetz HDPQ Guide (Portable) power quality analyzers offer the best combination of value & technology from Dranetz, or any other PQ analyzer\n available! It includes all of the features of the Dranetz HDPQ Visa instruments, but adds Wi-Fi communications, AnswerModules®, and a 10,000 cycle recording buffer for fault and inrush recording!\n

    \n

    The Dranetz HDPQ Guide is a true hand-held portable instrument with a built in 7″, tablet-like touch LCD display. 

    \n

    The Dranetz HDPQ Guide Power Quality Analyzers provides you the best in class power quality monitoring capabilities available. They measure to all\n current industry standards, including IEC 61000-4-30 Class A, IEC 61000-4-7, IEEE 1159, IEEE 519, IEEE 1459, and more. Equipped with 8 independent\n channels, automated setups provide instant detection of circuits and configurations, ensuring that the instrument is ready to successfully collect\n data in seconds. Users can select the length and mode of data collection, including troubleshooting, data logging, power quality surveys, energy,\n and load balancing. The Intelligent AnswerModule® feature provides consultant-like analysis of sag directivity, capacitor switching transient identification/directivity, and motor analysis/reporting.

    \n

    The Dranetz HDPQ Guide enable users to review data and change settings remotely from virtually any smartphone, tablet and mobile device, as well as\n with traditional PC and MAC laptops and desktops. Just hook up the instrument, close the cabinets to the ‘safe’ environment, and use either the\n VNC interface along with our Dran-View 7 software, or our Dranetz HDPQ Apple or Android Apps via Ethernet or W-Fi for remote control from anywhere\n with connectivity to the instrument.

    \n

    Dranetz HDPQ Guide – Precision\n

    \n
    • High Definition Power Quality & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle \n
    • Eight channels, 4 voltage & 4 current \n
    • AnswerModules – Sag directivity, PF capacitor identification, motor – automatic event categorization \n
    • Advanced PQ – IEC 61000-4-30 Class A & IEEE 1159 compliant \n
    • Harmonics – IEC 61000-4-7, IEEE 519 (2014) \n
    • Transient capabilities – V & I – waveshape triggers. Well beyond standards requirements \n
    • IEEE 1459 Advanced Power Measurements \n
    • 10,000 cycle pre/post trigger buffer \n
    • EN 50160 Ed 3 \n

    Dranetz HDPQ Guide  – Communications

    \n

    • Ethernet, Wi-Fi, USB, Bluetooth \n
    • VNC for full remote control from Dran-View 7 or a 3rd party App \n
    • Apple & Android apps with real time metering and alarm Dashboard

    \n

    Dranetz HDPQ Guide  – Safe & Rugged

    • Arc Flash Safety \n
    • UL/cUL listed and CE approved \n
    • Rugged enclosure with an easy to grip, shock absorbing, non-conductive boot (Dranetz HDPQ Guide only) \n
    • Drop tested to 6’ \n
    • Power supply cable retainer \n
    • Wire management in easel and hook \n
    • Automatic circuit detection and feedback on proper connection of the instrument User Interface \n

    Dranetz HDPQ Guide – User Interface 

    • 7” WVGA color touch display \n
    • Automatic setups – PQ, Demand and Energy \n
    • Tablet-like GUI that is icon driven, has taskbar shortcuts, and a Dashboard \n

    Dranetz HDPQ Guide  – Productivity

    • Mini-report – Screen snapshots, XML file. Easily uploaded and emailed! \n
    • PQ & Energy Dashboard’s for real time alarming \n
    • Bigger display for more productive local analysis\n
    • AnswerModules – automatic event categorization \n
    Dran-View 7 power quality analysis software \n
    • Rescue kit – Part of Dran-View 7. Correct problems with wiring, CT orientation, time errors and more \n
    • Post processing – Part of Dran-View 7. Compute harmonics and other parameters from the waveforms recorded by the instrument\n

     

    \n

    Dranetz HDPQ Guide  – Measured Parameters

    \n

    (4) Differential Voltage: 16 bit resolution

    \n
      \n
    • 0-1000Vrms, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • IEC 61000-4-30 Class A: 60-1000Vrms, ±0.1 % of Udin, range of 10% – 150% of Udin
    • \n
    • Transients – rms: 0-1414Vpk, ±0.2 % of Udin
    • \n
    \n

    (4) Current: 512 s/c, 16 bit resolution

    \n
      \n
    • Range (rms) probe dependent, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • Transients – Range probe dependent
    • \n
    \n

    Frequency: 10 sec window\n
    16-25Hz, 42.5-69Hz, +/- 0.01Hz

    \n

    Calculated Parameters

    \n

    Power/Energy – 1 Second sampling\n
    Real Power (W) – P: meets 0.2S requirements, range probe dep.\n
    Apparent Power (VA) – S: meets 0.2S requirements, range probe dep.\n
    Reactive Power (var) – Q: meets 0.2S requirements, range probe dep.\n
    Power Factor (W/VA) -”true” -1 to 0 to 1\n
    Displacement PF -1 to 0 to 1\n
    Demand (in W): meets 0.2S requirements, range probe dep.\n
    Energy (in Wh): meets 0.2S requirements, range probe dep.

    \n

    Distortion – 200ms, 3 sec, 10 min windows\n
    Vthd: 0-100%, +/- 5% for V>=1% Vnom,\n
    V Ind Harm: DC, 2-127, +/- 5% for V>=10% Vnom\n
    Ithd: 0-100%, +/- 5% for I>=1% Inom,\n
    I Ind Harm: DC, 2-63, +/- 5% for I>=10% Inom

    \n

    Misc.\n
    Pst – 10 minutes: 0.2-10, +/- 0.05 @ Pst=1\n
    Plt – 2 hours: 0.2-10, +/- 0.05 @ Pst=1

    \n

    Standards Compliance

    \n

    Power Quality\n
    IEC 61000-4-30 Class A: Edition 2 (2008)\n
    IEEE 1159: 2009

    \n

    Power\n
    IEEE 1459: 2000

    \n

    Harmonics\n
    IEC 61000-4-7 Class 1: Edition 2 (2008)\n
    IEEE 519: 2014

    \n

    Voltage Flicker\n
    IEC 61000-4-15: Edition 2 (2010)\n
    IEEE 1453: 2011

    \n

    Compliance/Testing\n
    EN 50160: 2010

    \n

    General Specifications 

    \n

    Dranetz HDPQ Guide

    \n
      \n
    • Size: (10″w x 8″h x 2.75″d), (25.4cm x 20.3cm x 7.0cm)
    • \n
    • Weight: 4.2lbs, 2kg
    • \n
    • Operating temperature: 0 to 50 deg C (32 to 122 deg F)
    • \n
    • Storage temperature: -20 to 55 deg C (-4 to 131 deg F)
    • \n
    • Humidity: 10-90% non condensing
    • \n
    \n

    Clock accuracy and resolution\n

    \n
      \n
    • Internal: +/- 1 sec/day at 25 deg C
    • \n
    • NTP: +/-10 msec
    • \n
    • GPS: +/-1 msec
    • \n
    \n

    AC Adapter: 100-240Vac 50/60Hz\n
    Battery capacity and charge time:

    \n
      \n
    • Dranetz HDPQ Guide: 3 hours run time on full charge, 3 hours charge time
    • \n
    \n

    Memory size: 4GB\n
    Display: 7” WVGA color graphic, Icon based touch LCD, LED Backlit 

    \n

    Communications

    \n

    Ethernet, 802.11 b/g/n Wireless (available without Wi-Fi as a special order)\n
    USB On The Go (OTG)\n
    Bluetooth via USB adapter\n
    VNC remote control\n
    Android & Apple App

    \n

    Ease of Use Features

    \n

    Automatic Setups – Start monitoring in seconds!
    Pre-programmed monitoring modes – Pre-configured setups for various applications
    AnswerModules®– Sag/Dip directivity, PF Cap, Motor Health
    Dashboards – Power Quality, Demand & Energy – Immediately know when events have been recorded
    Simultaneous Power Quality, Demand & Energy monitoring
    Mini-Report – Take screen snapshots that can be uploaded to your computer and included in reports, attached to emails, etc.

    \n

     

    Datasheet - Dranetz - HDPQ Guide \n
    \n

     

    \n
    ", "catalogId": 312399, "id": 10382090, "name": "Dranetz - HDPQ Guide - 10,000 trigger cycles, AnswerModules, Sag/Dip, Swell Transient, Harmonics", "url": "/industries-1/electrical-utility/dranetz-hdpq-guide", "title": "", "smallImage": "/_assets/images/product/HDPQ_Guide.png", "smallImageUrl": "/_assets/images/product/HDPQ_Guide.png", "largeImage": "/_assets/images/product/HDPQ_Guide.png", "largeImageUrl": "/_assets/images/product/HDPQ_Guide.png", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "HDPQ Guide", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/industries-1/electrical-utility/dranetz-hdpq-guide", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Xplorer, High Speed Transients, 10,000 trigger cycles, AnswerModules, Sag/Dip, Swell Transient, Harmonics

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
    \n

    Dranetz HDPQ® Xplorer Portable and

    \n

    Dranetz HDPQ® Xplorer SP (Rated IP65) Power Quality Analyzers

    \n

    Simply the best power quality monitor available – Don’t miss an event!

    \n

    New – Power from the Phase Feature; Power the Instrument from the Circuit Being Measured, or Another Source (SP Only)

    \n
    \n\n

    High Speed Transient Capture\n

    \n

    Tests 16/25Hz and 50/60Hz\n

    \n

    Powered by the Phase Being Measured!
    (SP Only)
    \n

    \n

    Advanced Remote Wireless Communications\n

    \n

    Made in the USA\n

    \n
    \n \"Dranetz \n

    The Dranetz HDPQ® Xplorer (portable) and Dranetz HDPQ Xplorer SP (IP65) power quality analyzers represent the top of the line in the Dranetz HDPQ family\n of products and offers you simply the best PQ monitoring available from Dranetz, or any other manufacturer! The Dranetz HDPQ Xplorer family includes\n all of the features of the Dranetz HDPQ Visa and Guide power quality instruments, but also adds high speed transient capture capabilities, so you’ll\n never miss an event!\n

    \n

    The Dranetz HDPQ Xplorer and Dranetz HDPQ Xplorer SP are the exact same instrument, but are in different enclosures. The Dranetz HDPQ Xplorer is a\n true hand-held portable instrument with a built in 7″, tablet-like touch LCD display. The Dranetz HDPQ Xplorer SP has the same measurement and\n communications capabilities, but is housed in an IP65 enclosure without an LCD display, and can also be powered by the circuit being measured.\n The IP65 enclosure of the Dranetz HDPQ Xplorer SP greatly expands the applications of the Dranetz HDPQ Xplorer into outdoor and harsh environments,\n along with other applications where an LCD display is undesirable.

    \n

    The Dranetz HDPQ Xplorer family of power quality instruments offers you the best in class monitoring capabilities available. It measures to all current\n industry standards, including IEC 61000-4-30 Class A, IEC 61000-4-7, IEEE 1159, IEEE 519, IEEE 1459, and more. With its high speed transient data\n capture (1 microsecond/channel) capabilities, this 8-channel workhorse simultaneously captures and characterizes thousands of parameters, by using\n a range of standard and customizable operating modes. The unique measurement capabilities include capture of low-medium-high frequency transients\n through peak, waveshape, rms duration and adaptive high-speed sampling, as well as power measurements to clearly characterize harmonics, non-sinusoidal,\n and unbalanced systems. The Intelligent AnswerModule® feature provides consultant-like analysis of sag directivity, capacitor switching transient\n identification/directivity and motor analysis/reporting.

    \n

    The Dranetz HDPQ Xplorer family enables users to review data and change settings remotely from virtually any smartphone, tablet and mobile device,\n as well as with traditional PC and MAC laptops and desktops. Just hook up the instrument, close the cabinets to the ‘safe’ environment, and use\n either the VNC interface along with our Dran-View 7 software or our Dranetz HDPQ Apple or Android Apps via Ethernet for remote control from anywhere\n with connectivity to the instrument.

    \n

    Dranetz HDPQ Xplorer Family – Precision

    • High Definition PQ & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle \n
    • High Speed Digitized Transients – 1us, 10 to 2000Vpk \n
    • Eight channels, 4 voltage & 4 current \n
    • AnswerModules – Sag directivity, PF capacitor identification, motor – automatic event categorization \n
    • Advanced PQ – IEC 61000-4-30 Class A & IEEE 1159 compliant \n
    • Harmonics – IEC 61000-4-7, IEEE 519 (2014) \n
    • Transient capabilities – V & I – waveshape triggers, high speed. Well beyond standards requirements \n
    • IEEE 1459 Advanced Power Measurements \n
    • 10,000 cycle pre/post trigger buffer \n
    • EN 50160 Ed 3\n

    Dranetz HDPQ Xplorer Family – Communications

    • Ethernet, Wi-Fi, USB, Bluetooth \n
    • VNC for full remote control from Dran-View 7 or a 3rd party App \n
    • Apple & Android apps with real time metering and alarm Dashboard\n

    Dranetz HDPQ Xplorer Family – Safe & Rugged

    • Arc Flash Safety \n
    • UL/cUL listed and CE approved \n
    • Rugged enclosure with an easy to grip, shock absorbing, non-conductive boot (Dranetz HDPQ Xplorer only) \n
    • IP65 enclosure for harsh and outdoor environments (Dranetz HDPQ Xplorer SP only) \n
    • Drop tested to 6’ (Dranetz HDPQ Xplorer only) \n
    • Power supply cable retainer (Dranetz HDPQ Xplorer only) \n
    • Wire management in easel and hook (Dranetz HDPQ Xplorer only) \n
    • Automatic circuit detection and feedback on proper connection of the instrument User Interface \n

    Dranetz HDPQ Xplorer Family – User Interface

    • 7” WVGA color touch display (Dranetz HDPQ Xplorer only) \n
    • Automatic setups – PQ, Demand and Energy \n
    • Tablet-like GUI that is icon driven, has taskbar shortcuts, and a Dashboard (only available remotely on the Dranetz HDPQ Xplorer SP)\n

    Dranetz HDPQ Xplorer Family – Productivity

    • Mini-report – Screen snapshots, XML file. Easily uploaded and emailed!\n
    • PQ & energy Dashboard’s for real time alarming\n
    • Bigger display for more productive local analysis (Dranetz HDPQ Xplorer only)\n
    • AnswerModules – automatic event categorization\n
    Dran-View 7 power quality analysis software\n
    • Rescue kit – Part of Dran-View 7. Correct problems with wiring, CT orientation, time errors and more\n
    • Post processing – Part of Dran-View 7. Compute harmonics and other parameters from the waveforms recorded by the instrument\n
    \n

     

    \n

    Measured Parameters

    \n

    (4) Differential Voltage: 512s/c, 16 bit resolution

    \n
      \n
    • 0-1000Vrms, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • IEC 61000-4-30 Class A: 60-1000Vrms, ±0.1 % of Udin, range of 10% – 150% of Udin
    • \n
    • Transients – rms: 0-1414Vpk, ±0.2 % of Udin
    • \n
    • Transients – High Speed: 10-2000Vpk, +/- 10% of reading, +/- 0.5% FS
    • \n
    \n

    (4) Current: 512 s/c, 16 bit resolution

    \n
      \n
    • Range (rms) probe dependent, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • Transients – Range probe dependent
    • \n
    • Transients – High Speed: Range probe dependent., 10% of Reading, +/- 0.5%FS
    • \n
    \n

    Frequency: 10 sec window

    \n
      \n
    • 16-25Hz, 41-69Hz, +/- 0.01Hz
    • \n
    \n

    Calculated Parameters

    \n

    Power/Energy – 1 Second sampling\n
    Real Power (W) – P: meets 0.2S requirements, range probe dep.\n
    Apparent Power (VA) – S: meets 0.2S requirements, range probe dep.\n
    Reactive Power (var) – Q: meets 0.2S requirements, range probe dep.\n
    Power Factor (W/VA) -”true” 1 to 0 to 1\n
    Displacement PF -1 to 0 to +1\n
    Demand (in W): meets 0.2S requirements, range probe dep.\n
    Energy (in Wh): meets 0.2S requirements, range probe dep.

    \n

    Distortion – 200ms, 3 sec, 10 min windows\n
    Vthd: 0-100%, +/- 5% for V>=1% Vnom,\n
    V Ind Harm: DC, 2-127, +/- 5% for V>=1% Vnom\n
    Ithd: 0-100%, +/- 5% for V>=1% Vnom,\n
    I Ind Harm: DC, 2-63, +/- 5% for V>=1% Vnom

    \n

    Misc.\n
    Pst – 10 minutes: 0.2-10, +/- 0.05 @ Pst=1 (50/60Hz only)\n
    Plt – 2 hours: 0.2-10, +/- 0.05 @ Pst=1 (50/60Hz only)

    \n

    Standards Compliance

    \n

    Power Quality IEC 61000-4-30 Class A: Edition 2 (2008)
    I
    EEE 1159: 2009

    \n

    Power\n
    IEEE 1459: 2000

    \n

    Harmonics\n
    IEC 61000-4-7 Class 1: Edition 2 (2008)

    IEEE 519: 2014\n

    Voltage Flicker\n
    IEC 61000-4-15: Edition 2 (2010)\n
    IEEE 1453: 2011

    \n

    Compliance/Testing\n
    EN 50160: 2010

    \n

    General Specifications\n

    \n

    Dranetz HDPQ Xplorer\n

    \n
      \n
    • Size: (10″w x 8″h x 2.75″d), (25.4cm x 20.3cm x 7.0cm)
    • \n
    • Weight: 4.2lbs, 2kg
    • \n
    • Operating temperature: 0 to 50 deg C (32 to 122 deg F)
    • \n
    • Storage temperature: -20 to 55 deg C (-4 to 131 deg F)
    • \n
    • Humidity: 10-90% non condensing
    • \n
    \n

    Dranetz HDPQ Xplorer SP (IP65)\n

    \n
      \n
    • Size: (11″w x 6.5″h x 2.5″d), (27.9cm x 16.5cm x 6.4cm)
    • \n
    • Weight: 3.8lbs, 1.72kg
    • \n
    • Operating temperature: -10 to 50 deg C (14 to 122 deg F)
    • \n
    • Storage temperature: -40 to 85 deg C (-40 to 185 deg F)
    • \n
    • Humidity: 10-90% non condensing
    • \n
    • Power Supply: 90-600VAC/500VDC (50/60Hz). Powered by the phase being measured, or other source
    • \n
    \n

    Clock accuracy and resolution\n

    \n
      \n
    • Internal: +/- 1 sec/day at 25 deg C
    • \n
    • NTP: +/-10 msec
    • \n
    • GPS: +/-1 msec
    • \n
    \n

    AC Adapter: 100-240Vac 50/60Hz
    Battery capacity and charge time:
    \n

    \n
      \n
    • Dranetz HDPQ Xplorer: 2.5 hours run time on full charge, 3 hours charge time
    • \n
    • Dranetz HDPQ Xplorer SP: 30 minutes run time on full charge, 3 hours charge time
    • \n
    \n

    Memory size: 4GB\n
    Display: 7” WVGA color graphic, Icon based touch LCD, LED Backlit (Dranetz HDPQ Xplorer only)\n
    Languages: English, German, Spanish, French, Italian, Swedish, Finnish, Polish, Chinese (traditional and simplified), Thai, Korean

    \n

    Communications

    \n

    Ethernet, 802.11 b/g/n Wireless (available without Wi-Fi as a special order)
    USB On the Go
    Bluetooth via USB adapter
    VNC remote control
    Android & Apple App

    \n

    Ease of Use Features

    \n

    Automatic Setups – Start monitoring in seconds!\n
    Pre-programmed monitoring modes – Pre-configured setups for various applications\n
    AnswerModules®– Sag/Dip directivity, PF Cap, Motor\n
    Dashboards – Power Quality, Demand & Energy – Immediately know when events have been recorded\n
    Simultaneous Power Quality, Demand & Energy monitoring\n
    Mini-Report – Take screen snapshots that can be uploaded to your computer and included in reports, attached to emails, etc.Power the instrument from the circuit being measured, or another source (SP Only)

    \n
    \n

    Click here for Brochure - Dranetz - HDPQ Xplorer \n

    \n
    \n
    ", "catalogId": 312399, "id": 10382092, "name": "Dranetz - HDPQ Xplorer, High Speed Transients, 10,000 trigger cycles, AnswerModules, Sag/Dip, Swell Transient, Harmonics", "url": "/industries-1/electrical-utility/dranetz-hdpq-xplorer", "title": "", "smallImage": "/_assets/images/product/HDPQ_Xplorer.png", "smallImageUrl": "/_assets/images/product/HDPQ_Xplorer.png", "largeImage": "/_assets/images/product/HDPQ_Xplorer.png", "largeImageUrl": "/_assets/images/product/HDPQ_Xplorer.png", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "HDPQ Xplorer", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/industries-1/electrical-utility/dranetz-hdpq-xplorer", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Xplorer 400, 400Hz monitoring, High Speed Transients, 10,000 trigger cycles, AnswerModules, Sag/Dip, Swell Transient, Harmonics

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
    \n

    Dranetz HDPQ® Xplorer 400 Portable and

    \n

    Dranetz HDPQ® Xplorer 400 SP (Rated IP65) Power Quality Analyzers

    \n

    Designed for Commercial, Military, Aviation, and Naval Industries with 400Hz Monitoring Capability! 

    \n

    Power from the Phase Feature; Power the Instrument from the Circuit Being Measured, or Another Source (SP Only)

    \n
    \n \"Dranetz \n
    \n

    Tests 50/60 and 400Hz

    \n

    High Speed Transient Capture

    \n

    Powered by the Phase Being Measured!
    (SP Only)

    \n

    Advanced Remote Wireless Communications

    \n

    Made in the USA

    \n
    \n
    \n \"Dranetz \n
    \n

     

    \n

    The Dranetz HDPQ Xplorer 400 (portable) and Dranetz HDPQ Xplorer 400 SP (IP65) power quality analyzers take PQ, Demand and Energy monitoring to new\n heights by adding 400Hz monitoring capabilities to the already powerful Dranetz HDPQ Xplorer family. The Dranetz HDPQ Xplorer 400 is designed for\n applications such as aviation, naval, military, etc. requiring 400Hz capabilities that are not available in most PQ and Energy analyzers which\n typically only measure 50/60Hz. The Dranetz HDPQ Xplorer 400 family was designed with 400Hz applications in mind, but it is also an all-purpose\n tool that can be used for any traditional 50/60Hz application. In addition to the 400Hz applications, the Dranetz HDPQ Xplorer 400 family is perfect\n for applications such as power quality surveys, voltage and current transient studies, fault recording, inrush, motor testing, harmonic analysis,\n advanced distortion analysis, demand/energy/load studies, and many more.

    \n

    The Dranetz HDPQ Xplorer 400 and Dranetz HDPQ Xplorer 400 SP are the exact same instrument, but are in different enclosures. The Dranetz HDPQ Xplorer\n 400 is a true hand-held portable instrument with a built in 7″, tablet-like touch LCD display. The Dranetz HDPQ Xplorer 400 SP has the same measurement\n and communications capabilities, but is housed in an IP65 enclosure without an LCD display, and can also be powered by the circuit being measured.\n The IP65 enclosure of the Dranetz HDPQ Xplorer 400 SP greatly expands the applications of the Dranetz HDPQ Xplorer 400 into outdoor and harsh environments,\n along with other applications where an LCD display is undesirable.

    \n

    The Dranetz HDPQ Xplorer 400 family of power quality instruments offers you the best in class monitoring capabilities available. In addition to the\n 400Hz capabilities, it measures to all current industry standards, including IEC 61000-4-30 Class A, IEC 61000-4-7, IEEE 1159, IEEE 519, IEEE 1459,\n and more. With its high speed transient data capture (1 microsecond/channel) capabilities, this 8-channel workhorse simultaneously captures and\n characterizes thousands of parameters, by using a range of standard and customizable operating modes. The unique measurement capabilities include\n capture of low-medium-high frequency transients through peak, waveshape, rms duration and adaptive high-speed sampling, as well as power measurements\n to clearly characterize harmonics, non-sinusoidal, and unbalanced systems. The Intelligent AnswerModule® feature provides consultant-like analysis\n of sag directivity, capacitor switching transient identification/directivity and motor analysis/reporting.

    \n

    The Dranetz HDPQ Xplorer 400 family enables users to review data and change settings remotely from virtually any smartphone, tablet, mobile device,\n as well as with traditional PC and MAC laptops and desktops. Just hook up the instrument, close the cabinets to the ‘safe’ environment, and use\n either the VNC interface along with our Dran-View 7 software or our Dranetz HDPQ Apple or Android Apps via Ethernet for remote control from anywhere\n with connectivity to the instrument.

    \n

    Dranetz HDPQ Xplorer 400 Family – Precision

    • High Definition PQ & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle \n
    • High Speed Digitized Transients to 1us – 10 to 2000Vpk \n
    • 50/60Hz and 400Hz operating modes \n
    • Eight channels, 4 voltage & 4 current \n
    • AnswerModules – Sag directivity, PF capacitor identification, motor – automatic event categorization \n
    • Advanced PQ – IEC 61000-4-30 Class A & IEEE 1159 compliant \n
    • Harmonics – IEC 61000-4-7, IEEE 519 (2014) \n
    • Transient capabilities – V & I – waveshape triggers, high speed. Well beyond standards requirements \n
    • IEEE 1459 Advanced Power Measurements \n
    • 10,000 cycle pre/post trigger buffer \n
    • EN 50160 Ed 3 \n

    Dranetz HDPQ Xplorer 400 Family – Communications

    • Ethernet, Wi-Fi, USB, Bluetooth \n
    • VNC for full remote control from Dran-View 7 or a 3rd party App \n
    • Apple & Android apps with real time metering and alarm Dashboard \n

    Dranetz HDPQ Xplorer 400 Family – Safe & Rugged

    • Arc Flash Safety \n
    • UL/cUL listed and CE approved \n
    • Rugged enclosure with an easy to grip, shock absorbing, non-conductive boot (Dranetz HDPQ Xplorer 400 only) \n
    • IP65 enclosure for harsh and outdoor environments (Dranetz HDPQ Xplorer 400 SP only) \n
    • Drop tested to 6’ (Dranetz HDPQ Xplorer 400 only) \n
    • Power supply cable retainer (Dranetz HDPQ Xplorer 400 only) \n
    • Wire management in easel and hook (Dranetz HDPQ Xplorer 400 only) \n
    • Automatic circuit detection and feedback on proper connection of the instrument User Interface \n

    Dranetz HDPQ Xplorer 400 Family – User Interface

    • 7” WVGA color touch display (Dranetz HDPQ Xplorer 400 only) \n
    • Automatic setups – PQ, Demand and Energy \n
    • Tablet-like GUI that is icon driven, has taskbar shortcuts, and a Dashboard (only available remotely on the Dranetz HDPQ Xplorer 400 SP) \n

    Dranetz HDPQ Xplorer 400 Family – Productivity

    • Mini-report – Screen snapshots, XML file. Easily uploaded and emailed! \n
    • PQ & energy Dashboard’s for real time alarming \n
    • Bigger display for more productive local analysis (Dranetz HDPQ Xplorer 400 only) \n
    • AnswerModules – automatic event categorization \n
    Dran-View 7 power quality analysis software \n
    • Rescue kit – Part of Dran-View 7. Correct problems with wiring, CT orientation, time errors and more \n
    • Post processing – Part of Dran-View 7. Compute harmonics and other parameters from the waveforms recorded by the instrument \n
    \n

     

    \n

    Measured Parameters

    \n

    (4) Differential Voltage: 512 s/c, 16 bit resolution

    \n
      \n
    • 0-1000Vrms, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • IEC 61000-4-30 Class A: 60-1000Vrms, ±0.1 % of Udin, range of 10% – 150% of Udin
    • \n
    • Transients – rms: 0-1414Vpk, ±0.2 % of Udin
    • \n
    • Transients – High Speed: 10-2000Vpk, +/- 10% of reading, +/- 0.5% FS
    • \n
    \n

    (4) Current: 512 s/c, 16 bit resolution

    \n
      \n
    • Range (rms) probe dependent, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • Transients – Range probe dependent
    • \n
    • Transients – High Speed: Range probe dependent., 10% of Reading, +/- 0.5% FS
    • \n
    \n

    Frequency: 10 sec window

    \n
      \n
    • 42.5-69Hz, +/- 0.01Hz, 380-420Hz +/- 0.1Hz
    • \n
    \n

    Calculated Parameters

    \n

    Power/Energy – 1 Second sampling\n
    Real Power (W) – P: meets 0.2S requirements, range probe dependent\n
    Apparent Power (VA) – S: meets 0.2S requirements, range probe dependent\n
    Reactive Power (var) – Q: meets 0.2S requirements, range probe dependent\n
    Power Factor (W/VA) -”true” -1 to 0 to +1\n
    Displacement PF 1 to 0 to 1\n
    Demand (in W): meets 0.2S requirements, range probe dependent\n
    Energy (in Wh): meets 0.2S requirements, range probe dependent

    \n

    Distortion – 200ms, 3 sec, 10 min windows\n
    Vthd: 0-100%, +/- 5% for V>=1% Vnom,\n
    V Ind Harm: DC, 2-127 @50/60Hz, 2-15 @400Hz, +/- 5% for V>=1% Vnom\n
    Ithd: 0-100%, +/- 5% for V>=1% Inom,\n
    I Ind Harm: DC, [email protected]/60Hz, 2-15 @400Hz, +/- 5% for I>=1% Inom

    \n

    Misc.\n
    Pst – 10 minutes: 0.2-10, +/- 0.05 @ Pst=1 (50/60Hz only)\n
    Plt – 2 hours: 0.2-10, +/- 0.05 @ Pst=1 (50/60Hz only)

    \n

    Standards Compliance (50/60Hz systems only)

    \n

    Power Quality IEC 61000-4-30 Class A: Edition 2 (2008)\n
    IEEE 1159: 2009

    \n

    Power\n
    IEEE 1459: 2000

    \n

    Harmonics\n
    IEC 61000-4-7 Class 1: Edition 2 (2008)\n
    IEEE 519: 2014

    \n

    Voltage Flicker\n
    IEC 61000-4-15: Edition 2 (2010)\n
    IEEE 1453: 2011

    \n

    Compliance/Testing\n
    EN 50160: 2010

    \n

    General Specifications\n

    \n

    Dranetz HDPQ Xplorer 400\n

    \n
      \n
    • Size: (10″w x 8″h x 2.75″d), (25.4cm x 20.3cm x 7.0cm)
    • \n
    • Weight: 4.2lbs, 2kg
    • \n
    • Operating temperature: 0 to 50 deg C (32 to 122 deg F)
    • \n
    • Storage temperature: -20 to 55 deg C (-4 to 131 deg F)
    • \n
    • Humidity: 10-90% non condensing
    • \n
    \n

    Dranetz HDPQ Xplorer 400 SP (IP65)\n

    \n
      \n
    • Size: (11″w x 6.5″h x 2.5″d), (27.9cm x 16.5cm x 6.4cm)
    • \n
    • Weight: 3.8lbs, 1.72kg
    • \n
    • Operating temperature: -10 to 50 deg C (14 to 122 deg F)
    • \n
    • Storage temperature: -40 to 85 deg C (-40 to 185 deg F)
    • \n
    • Humidity: 10-90% non condensing
    • \n
    • Power Supply: 90-600VAC/500VDC (50/60Hz). Powered by the phase being measured, or other source
    • \n
    \n

    Clock accuracy and resolution\n

    \n
      \n
    • Internal: +/- 1 sec/day at 25 deg C
    • \n
    • NTP: +/-10 msec
    • \n
    • GPS: +/-1 msec
    • \n
    \n

    AC Adapter: 100-240Vac 50/60Hz
    Battery capacity and charge time:
    \n

    \n
      \n
    • Dranetz HDPQ Xplorer 400: 2.5 hours run time on full charge, 3 hours charge time
    • \n
    • Dranetz HDPQ Xplorer 400 SP: 30 minutes run time on full charge, 3 hours charge time
    • \n
    \n

    Memory size: 4GB\n
    Display: 7” WVGA color graphic, Icon based touch LCD, LED Backlit (Dranetz HDPQ Xplorer 400 only)\n
    Languages: English, German, Spanish, French, Italian, Swedish, Finnish, Polish, Chinese (traditional and simplified), Thai, Korean

    \n

    Communications

    \n

     Ethernet, 802.11 b/g/n Wireless (available without Wi-Fi as a special order)
    USB On the Go
    Bluetooth via USB adapter
    VNC remote control
    Android & Apple App

    \n

    Ease of Use Features\n \n

    \n

    Automatic Setups – Start monitoring in seconds!\n
    Pre-programmed monitoring modes – Pre-configured setups for various applications\n
    AnswerModules®– Sag/Dip directivity, PF Cap, Motor\n
    Dashboards – Power Quality, Demand & Energy – Immediately know when events have been recorded\n
    Simultaneous Power Quality, Demand & Energy monitoring\n
    Mini-Report – Take screen snapshots that can be uploaded to your computer and included in reports, attached to emails, etc.Power the instrument from the circuit being measured, or another source (SP Only)

    \n

     

    \n
    Click here for Brochure - Dranetz - HDPQ Xplorer 400\n
    ", "catalogId": 312710, "id": 10382229, "name": "Dranetz - HDPQ Xplorer 400, 400Hz monitoring, High Speed Transients, 10,000 trigger cycles, AnswerModules, Sag/Dip, Swell Transient, Harmonics", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-400", "title": "", "smallImage": "/_assets/images/product/HDPQ_Xplorer.png", "smallImageUrl": "/_assets/images/product/HDPQ_Xplorer.png", "largeImage": "/_assets/images/product/HDPQ_Xplorer.png", "largeImageUrl": "/_assets/images/product/HDPQ_Xplorer.png", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "HDPQ Xplorer 400", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-400", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ VISA SP- (Rated IP65) 100 trigger cycles, 3 transient triggers

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
    \n

    HDPQ Visa SP (Rated IP65) Power Quality Analyzers

    \n

    The Best Value in Power Quality Monitoring

    \n

    Power from the Phase Feature; Power the Instrument from the Circuit Being Measured, or Another Source 

    \n
    \n
    \n

    Tests 16/25Hz and 50/60Hz \n

    \n
    \n

    Powered by the Phase Being Measured!\n

    \n

     Wired Ethernet Communications \n

    \n

    Bluetooth Optional\n

    \n

    GPS Optional (Factory installed only)\n

    \n

    Made in the USA\n

    \n
    \n
    \n \"Dranetz \n

    The Dranetz HDPQ Visa SP (IP65) power quality analyzers offer the best value in power quality, demand, and energy monitoring from Dranetz, or any\n other Power Quality analyzer manufacturer! No other product at this price point comes close to matching the benefits and features provided\n by the Dranetz HDPQ Visa family of products.\n

    \n
    \n
    \n
    \n

    The Dranetz HDPQ Visa SP has the same measurement and communications capabilities as the Dranetz HDPQ Visa, but is housed in an IP65 enclosure without\n an LCD display, and can also be powered by the circuit being measured. The IP65 enclosure of the Dranetz HDPQ Visa SP greatly expands the applications\n of the Dranetz HDPQ Visa into outdoor and harsh environments, along with other applications where an LCD display is undesirable.

    \n

    The HDPQ Visa SP enables users to review data and change settings remotely from virtually any smartphone, tablet and mobile device, as well as with\n traditional PC and MAC laptops and desktops. Just hook up the instrument, close the cabinets to the ‘safe’ environment, and use either the VNC\n interface along with our Dran-View 7 software, or our Dranetz HDPQ Apple or Android Apps via Ethernet for remote control from anywhere with connectivity\n to the instrument.

    \n
    \n

    Dranetz HDPQ Visa SP – Precision

    • High Definition PQ & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle\n
    • Eight channels, 4 voltage & 4 current\n
    • Advanced PQ – IEC 61000-4-30 Class A & IEEE 1159 compliant\n
    • Harmonics – IEC 61000-4-7, IEEE 519 (2014)\n
    • Transient capabilities – V & I waveshape triggers. Well beyond standards requirements\n
    • 100 cycle pre/post trigger buffer\n
    • EN 50160 Ed 3\n
    • Motor AnswerModule®\n

    Dranetz HDPQ Visa SP – Communications

    • Ethernet, USB, Bluetooth – Optional\n
    • VNC for full remote control from Dran-View 7 or a 3rd party App\n
    • Apple & Android apps with real time metering and alarm Dashboard\n

    Dranetz HDPQ Visa SP – Safe & Rugged

    • Arc Flash Safety \n
    • UL/cUL listed and CE approved \n
    • Rugged enclosure with an easy to grip, shock absorbing, non-conductive boot (Dranetz HDPQ Visa only) \n
    • Power supply cable retainer and wire management (Dranetz HDPQ Visa only) \n
    • IP65 enclosure for harsh and outdoor environments (Dranetz HDPQ Visa SP only) \n
    • Drop tested to 6’ (Dranetz HDPQ Visa only) \n
    • Automatic circuit detection and feedback on proper connection of the instrument\n

    Dranetz HDPQ Visa SP – User Interface

    • Automatic setups – PQ, Demand and Energy \n
    • Tablet-like GUI that is icon driven, has taskbar shortcuts, and a Dashboard (only available remotely)\n

    Dranetz HDPQ SP – Productivity

    • Mini-Report – Screen snapshots, XML file. Easily uploaded and emailed!\n
    • PQ & Energy Dashboard’s for real time alarming\n
    Dran-View 7\n power quality analysis software\n
    • Rescue kit – Part of Dran-View 7. Correct problems with wiring, CT orientation, time errors and more\n

    • Post processing – Part of Dran-View 7. Compute harmonics and other parameters from the waveforms recorded by the instrument

    \n

    Dranetz HDPQ Visa SP – Measured Parameters\n

    \n

    (4) Differential Voltage: 16 bit resolution

    \n
      \n
    • 0-1000Vrms, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • IEC 61000-4-30 Class A: 60-1000Vrms, ±0.1 % of Udin, range of 10% ~ 150% of Udin
    • \n
    • Transients – 0-1414Vpk, +/- .2% of Udin
    • \n
    \n

    (4) Current: 512 samples/cycle, 16 bit resolution

    \n
      \n
    • Range (rms) probe dependent, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • Transients – Range probe dependent
    • \n
    \n

    Frequency: 10 sec window

    \n
      \n
    • 16-25Hz, 42.5-69Hz, +/- 0.01Hz
    • \n
    \n

    Calculated Parameters

    \n

    Power/Energy – 1 Second sampling\n
    Real Power (W) – P: meets 0.2S requirements, range probe dependent\n
    Apparent Power (VA) – S: meets 0.2S requirements, range probe dependent\n
    Reactive Power (var) – Q: meets 0.2S requirements, range probe dependent\n
    Power Factor (W/VA) -”true” -1 to 0 to 1\n
    Displacement PF -1 to 0 to 1\n
    Demand (in W): meets 0.2S requirements, range probe dependent\n
    Energy (in Wh): meets 0.2S requirements, range probe dependent

    \n

    Distortion – 200ms, 3 sec, 10 min windows\n
    Vthd: 0-100%, +/- 5% for V>=1% Vnom,\n
    V Ind Harm: DC, 2-127, +/- 5% for V>=1% Vnom\n
    Ithd: 0-100%, +/- 5% for I>=1% Inom,\n
    I Ind Harm: DC, 2-63, +/- 5% for I>=1% Inom

    \n

    Misc.\n
    Pst – 10 minutes: 0.2-10, +/- 0.05 @ Pst=1\n
    Plt – 2 hours: 0.2-10, +/- 0.05 @ Pst=1

    \n

    Standards Compliance

    \n

    Power Quality\n
    IEC 61000-4-30 Class A: Edition 2 (2008)\n
    IEEE 1159: 2009

    \n

    Power\n
    IEEE 1459: 2000

    \n

    Harmonics\n
    IEC 61000-4-7 Class 1: Edition 2 (2008)\n
    IEEE 519: 2014

    \n

    Voltage Flicker\n
    IEC 61000-4-15: Edition 2 (2010)\n
    IEEE 1453: 2011

    \n

    Compliance/Testing\n
    EN 50160: 2010

    \n

    General Specifications

    \n

    Dranetz HDPQ Visa SP (IP65)\n

    \n
      \n
    • Size: (11″w x 6.5″h x 2.5″d), (27.9cm x 16.5cm x 6.4cm)
    • \n
    • Weight: 3.8lbs, 1.72kg
    • \n
    • Operating temperature: -10 to 50 deg C (14 to 122 deg F)
    • \n
    • Storage temperature: -40 to 85 deg C (-40 to 185 deg F)
    • \n
    • Humidity: 10-90 non condensing
    • \n
    • Power Supply: 90-600VAC/500VDC (50/60Hz). Powered by the phase being measured, or other source
    • \n
    \n

    Clock accuracy and resolution

    \n
      \n
    • Internal: +/- 1 sec/day at 25 deg C
    • \n
    • NTP: +/-10 msec
    • \n
    • GPS: +/-1 msec
    • \n
    \n

    Battery capacity and charge time:

    \n
      \n
    • Dranetz HDPQ Visa SP: 30 minutes run time on full charge, 3 hours charge time
    • \n
    \n

    Memory size: 4GB\n

    \n

    Communications:\n

    \n

    Ethernet\n
    Bluetooth (optional)\n
    USB On the Go (OTG)\n
    VNC remote control\n
    Android & Apple Apps

    \n

    Ease of Use Features

    \n

    Automatic Setups – Start monitoring in seconds!\n
    Pre-programmed monitoring modes – Pre-configured setups for various applications\n
    Dashboards – Power Quality, Demand & Energy – Immediately know when events have been recorded\n
    Simultaneous Power Quality, Demand & Energy monitoring\n
    Mini-Report – Take screen snapshots that can be uploaded to your computer and included in reports, attached to emails, etc.\n
    Power the instrument from the circuit being measured, or another source (SP Only)

    \n

    Datasheet - Dranetz - HDPQ VISA \n

    \n

    Datasheet - Dranetz - HDPQ-SP Weatherproof Packages
    \n

    \n

     

    \n

     

    \n

     

    \n

     

    ", "catalogId": 312399, "id": 11151116, "name": "Dranetz - HDPQ VISA SP- (Rated IP65) 100 trigger cycles, 3 transient triggers", "url": "/industries-1/electrical-utility/dranetz-hdpq-visa-sp-rated-ip65-100-trigger-cycles-3-transient-triggers", "title": "", "smallImage": "/_assets/images/product/HDPQ-SP-Visa-resized-1.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-SP-Visa-resized-1.jpg", "largeImage": "/_assets/images/product/HDPQ-SP-Visa-resized-1.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-SP-Visa-resized-1.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "HDPQ-SPVAFLEX3KPKG-IP", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/industries-1/electrical-utility/dranetz-hdpq-visa-sp-rated-ip65-100-trigger-cycles-3-transient-triggers", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Guide SP - (Rated IP65) 10,000 trigger cycles, Sag, PF Correction, Bluetooth, Wifi

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "

    Dranetz HDPQ Guide SP (Rated IP65) Power Quality Analyzers

    \n

    The Best Combination Of Value and Technology In a Power Quality Analyzer – Safe, Powerful, & Intelligent\n
    \n

    \n

    Power from the Phase Feature; Power the Instrument from the Circuit Being Measured, or Another Source 

    \n
    \n
    \n

    Tests 16/25Hz and 50/60Hz\n

    \n
    \n

    Powered by the Phase Being Measured!
     

    \n

    Remote Wi-Fi Communications 

    \n

    AnswerModules® Included

    \n

    GPS Optional (Factory installed only)

    \n

    Made in the USA

    \n
    \n
    \n \"Dranetz \n

    The  Dranetz HDPQ Guide SP (IP65) power quality analyzers offer the best combination of value & technology from Dranetz, or any other PQ analyzer\n available! It includes all of the features of the Dranetz HDPQ Guide instruments, but adds Wi-Fi communications, AnswerModules®, and a 10,000 cycle recording buffer for fault and inrush recording!\n

    \n

    The Dranetz HDPQ Guide SP has the same measurement and communications capabilities as the Dranetz HDPQ Guide, but is housed in an IP65 enclosure without\n an LCD display, and can also be powered by the circuit being measured. The IP65 enclosure of the Dranetz HDPQ Guide SP greatly expands the applications\n of the Dranetz HDPQ Guide into outdoor and harsh environments, along with other applications where an LCD display is undesirable.

    \n

    The Dranetz HDPQ Guide SP Power Quality Analyzers provides you the best in class power quality monitoring capabilities available. They measure to all\n current industry standards, including IEC 61000-4-30 Class A, IEC 61000-4-7, IEEE 1159, IEEE 519, IEEE 1459, and more. Equipped with 8 independent\n channels, automated setups provide instant detection of circuits and configurations, ensuring that the instrument is ready to successfully collect\n data in seconds. Users can select the length and mode of data collection, including troubleshooting, data logging, power quality surveys, energy,\n and load balancing. The Intelligent AnswerModule® feature provides consultant-like analysis of sag directivity, capacitor switching transient identification/directivity, and motor analysis/reporting.

    \n

    The  Dranetz HDPQ Guide SP enable users to review data and change settings remotely from virtually any smartphone, tablet and mobile device, as\n well as with traditional PC and MAC laptops and desktops. Just hook up the instrument, close the cabinets to the ‘safe’ environment, and use either\n the VNC interface along with our Dran-View 7 software, or our Dranetz HDPQ Apple or Android Apps via Ethernet or W-Fi for remote control from anywhere\n with connectivity to the instrument.

    \n

    Dranetz HDPQ Guide SP – Precision\n

    \n
    • High Definition Power Quality & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle \n
    • Eight channels, 4 voltage & 4 current \n
    • AnswerModules – Sag directivity, PF capacitor identification, motor – automatic event categorization \n
    • Advanced PQ – IEC 61000-4-30 Class A & IEEE 1159 compliant \n
    • Harmonics – IEC 61000-4-7, IEEE 519 (2014) \n
    • Transient capabilities – V & I – waveshape triggers. Well beyond standards requirements \n
    • IEEE 1459 Advanced Power Measurements \n
    • 10,000 cycle pre/post trigger buffer \n
    • EN 50160 Ed 3 \n

    Dranetz HDPQ Guide SP – Communications

    \n

    • Ethernet, Wi-Fi, USB, Bluetooth \n
    • VNC for full remote control from Dran-View 7 or a 3rd party App \n
    • Apple & Android apps with real time metering and alarm Dashboard

    \n

    Dranetz HDPQ Guide & HDPQ Guide SP – Safe & Rugged

    • Arc Flash Safety \n
    • UL/cUL listed and CE approved \n
    • IP65 enclosure for harsh and outdoor environments \n
    • Automatic circuit detection and feedback on proper connection of the instrument User Interface \n

    Dranetz HDPQ Guide SP – User Interface 

    • Automatic setups – PQ, Demand and Energy \n
    • Tablet-like GUI that is icon driven, has taskbar shortcuts, and a Dashboard (only available remotely)\n

    Dranetz HDPQ Guide SP – Productivity

    • Mini-report – Screen snapshots, XML file. Easily uploaded and emailed! \n
    • PQ & Energy Dashboard’s for real time alarming \n
    • AnswerModules – automatic event categorization \n
    Dran-View 7 power quality analysis software \n
    • Rescue kit – Part of Dran-View 7. Correct problems with wiring, CT orientation, time errors and more \n
    • Post processing – Part of Dran-View 7. Compute harmonics and other parameters from the waveforms recorded by the instrument\n

    Dranetz HDPQ Guide SP – Measured Parameters\n

    \n

    (4) Differential Voltage: 16 bit resolution

    \n
      \n
    • 0-1000Vrms, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • IEC 61000-4-30 Class A: 60-1000Vrms, ±0.1 % of Udin, range of 10% – 150% of Udin
    • \n
    • Transients – rms: 0-1414Vpk, ±0.2 % of Udin
    • \n
    \n

    (4) Current: 512 s/c, 16 bit resolution

    \n
      \n
    • Range (rms) probe dependent, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • Transients – Range probe dependent
    • \n
    \n

    Frequency: 10 sec window\n
    16-25Hz, 42.5-69Hz, +/- 0.01Hz

    \n

    Calculated Parameters

    \n

    Power/Energy – 1 Second sampling\n
    Real Power (W) – P: meets 0.2S requirements, range probe dep.\n
    Apparent Power (VA) – S: meets 0.2S requirements, range probe dep.\n
    Reactive Power (var) – Q: meets 0.2S requirements, range probe dep.\n
    Power Factor (W/VA) -”true” -1 to 0 to 1\n
    Displacement PF -1 to 0 to 1\n
    Demand (in W): meets 0.2S requirements, range probe dep.\n
    Energy (in Wh): meets 0.2S requirements, range probe dep.

    \n

    Distortion – 200ms, 3 sec, 10 min windows\n
    Vthd: 0-100%, +/- 5% for V>=1% Vnom,\n
    V Ind Harm: DC, 2-127, +/- 5% for V>=10% Vnom\n
    Ithd: 0-100%, +/- 5% for I>=1% Inom,\n
    I Ind Harm: DC, 2-63, +/- 5% for I>=10% Inom

    \n

    Misc.\n
    Pst – 10 minutes: 0.2-10, +/- 0.05 @ Pst=1\n
    Plt – 2 hours: 0.2-10, +/- 0.05 @ Pst=1

    \n

    Standards Compliance

    \n

    Power Quality\n
    IEC 61000-4-30 Class A: Edition 2 (2008)\n
    IEEE 1159: 2009

    \n

    Power\n
    IEEE 1459: 2000

    \n

    Harmonics\n
    IEC 61000-4-7 Class 1: Edition 2 (2008)\n
    IEEE 519: 2014

    \n

    Voltage Flicker\n
    IEC 61000-4-15: Edition 2 (2010)\n
    IEEE 1453: 2011

    \n

    Compliance/Testing\n
    EN 50160: 2010

    \n

    General Specifications 

    \n

    Dranetz HDPQ Guide SP (IP65)\n

    \n
      \n
    • Size: (11″w x 6.5″h x 2.5″d), (27.9cm x 16.5cm x 6.4cm)
    • \n
    • Weight: 3.8lbs, 1.72kg
    • \n
    • Operating temperature: -10 to 50 deg C (14 to 122 deg F)
    • \n
    • Storage temperature: -40 to 85 deg C (-40 to 185 deg F)
    • \n
    • Humidity: 10-90% non condensing
    • \n
    • Power Supply: 90-600VAC/500VDC (50/60Hz). Powered by the phase being measured, or other source
    • \n
    \n

    Clock accuracy and resolution

    \n
      \n
    • Internal: +/- 1 sec/day at 25 deg C
    • \n
    • NTP: +/-10 msec
    • \n
    • GPS: +/-1 msec
    • \n
    \n

    AC Adapter: 100-240Vac 50/60Hz\n
    Battery capacity and charge time:

    \n
      \n
    • Dranetz HDPQ Guide SP: 30 minutes run time on full charge, 3 hours charge time
    • \n
    \n

    Memory size: 4GB\n
     

    \n

    Communications\n

    \n

    Ethernet, 802.11 b/g/n Wireless (available without Wi-Fi as a special order)\n
    USB On The Go (OTG)\n
    Bluetooth via USB adapter\n
    VNC remote control\n
    Android & Apple App

    \n

    Ease of Use Features

    \n

    Automatic Setups – Start monitoring in seconds!
    Pre-programmed monitoring modes – Pre-configured setups for various applications
    AnswerModules®– Sag/Dip directivity, PF Cap, Motor Health
    Dashboards – Power Quality, Demand & Energy – Immediately know when events have been recorded
    Simultaneous Power Quality, Demand & Energy monitoring
    Mini-Report – Take screen snapshots that can be uploaded to your computer and included in reports, attached to emails, etc.

    \n

    Power the instrument from the circuit being measured, or another source (SP Only)

    Datasheet - Dranetz - HDPQ Guide \n
    \n

    \n

    \n

    Datasheet - Dranetz - HDPQ-SP Weatherproof Packages\n

     \n

     

    \n
     
    \n
    \n
    \n

     

    \n
    ", "catalogId": 312399, "id": 11151128, "name": "Dranetz - HDPQ Guide SP - (Rated IP65) 10,000 trigger cycles, Sag, PF Correction, Bluetooth, Wifi", "url": "/industries-1/electrical-utility/dranetz-hdpq-guide-sp-rated-ip65-10-000-trigger-cycles-sag-pf-correction-bluetooth-wifi-copy", "title": "", "smallImage": "/_assets/images/product/HDPQ-SPGuide-resized-1.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-SPGuide-resized-1.jpg", "largeImage": "/_assets/images/product/HDPQ-SPGuide-resized-1.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-SPGuide-resized-1.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "HDPQ-SPGAFLEX3KPKG-IP", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/industries-1/electrical-utility/dranetz-hdpq-guide-sp-rated-ip65-10-000-trigger-cycles-sag-pf-correction-bluetooth-wifi-copy", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Xplorer SP - (Rated IP65) Transients to 1us, 4 transient triggers

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
    \n

    Dranetz HDPQ® Xplorer SP (Rated IP65) Power Quality Analyzers

    \n

    Simply the best power quality monitor available – Don’t miss an event!

    \n

    New – Power from the Phase Feature; Power the Instrument from the Circuit Being Measured, or Another Source (SP Only)

    \n
    \n
    High Speed Transient Capture\n
    \n

    Tests 16/25Hz and 50/60Hz\n

    \n

    Powered by the Phase Being Measured!\n

    \n

    Advanced Remote Wireless Communications \n

    \n

    Made in the USA\n

    \n
    \n \"Dranetz \n

    The  Dranetz HDPQ Xplorer SP (IP65) power quality analyzers represent the top of the line in the Dranetz HDPQ family of products and offers you\n simply the best PQ monitoring available from Dranetz, or any other manufacturer! The Dranetz HDPQ Xplorer family includes all of the features of\n the Dranetz HDPQ Visa and Guide power quality instruments, but also adds high speed transient capture capabilities, so you’ll never miss an event!\n

    \n

    The Dranetz HDPQ Xplorer SP has the same measurement and communications capabilities as the Dranetz HDPQ Xplorer, but is housed in an IP65 enclosure\n without an LCD display, and can also be powered by the circuit being measured. The IP65 enclosure of the Dranetz HDPQ Xplorer SP greatly expands\n the applications of the Dranetz HDPQ Xplorer into outdoor and harsh environments, along with other applications where an LCD display is undesirable.

    \n

    The Dranetz HDPQ Xplorer family of power quality instruments offers you the best in class monitoring capabilities available. It measures to all current\n industry standards, including IEC 61000-4-30 Class A, IEC 61000-4-7, IEEE 1159, IEEE 519, IEEE 1459, and more. With its high speed transient data\n capture (1 microsecond/channel) capabilities, this 8-channel workhorse simultaneously captures and characterizes thousands of parameters, by using\n a range of standard and customizable operating modes. The unique measurement capabilities include capture of low-medium-high frequency transients\n through peak, waveshape, rms duration and adaptive high-speed sampling, as well as power measurements to clearly characterize harmonics, non-sinusoidal,\n and unbalanced systems. The Intelligent AnswerModule® feature provides consultant-like analysis of sag directivity, capacitor switching transient\n identification/directivity and motor analysis/reporting.

    \n

    The Dranetz HDPQ Xplorer family enables users to review data and change settings remotely from virtually any smartphone, tablet and mobile device,\n as well as with traditional PC and MAC laptops and desktops. Just hook up the instrument, close the cabinets to the ‘safe’ environment, and use\n either the VNC interface along with our Dran-View 7 software or our Dranetz HDPQ Apple or Android Apps via Ethernet for remote control from anywhere\n with connectivity to the instrument.

    \n

    Dranetz HDPQ Xplorer Family – Precision

    • High Definition PQ & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle \n
    • High Speed Digitized Transients – 1us, 10 to 2000Vpk \n
    • Eight channels, 4 voltage & 4 current \n
    • AnswerModules – Sag directivity, PF capacitor identification, motor – automatic event categorization \n
    • Advanced PQ – IEC 61000-4-30 Class A & IEEE 1159 compliant \n
    • Harmonics – IEC 61000-4-7, IEEE 519 (2014) \n
    • Transient capabilities – V & I – waveshape triggers, high speed. Well beyond standards requirements \n
    • IEEE 1459 Advanced Power Measurements \n
    • 10,000 cycle pre/post trigger buffer \n
    • EN 50160 Ed 3\n

    Dranetz HDPQ Xplorer Family – Communications

    • Ethernet, Wi-Fi, USB, Bluetooth \n
    • VNC for full remote control from Dran-View 7 or a 3rd party App \n
    • Apple & Android apps with real time metering and alarm Dashboard\n

    Dranetz HDPQ Xplorer Family – Safe & Rugged

    • Arc Flash Safety \n
    • UL/cUL listed and CE approved \n
    • IP65 enclosure for harsh and outdoor environments \n
    • Automatic circuit detection and feedback on proper connection of the instrument User Interface \n

    Dranetz HDPQ Xplorer Family – User Interface

    • Automatic setups – PQ, Demand and Energy \n
    • Tablet-like GUI that is icon driven, has taskbar shortcuts, and a Dashboard (only available remotely)\n

    Dranetz HDPQ Xplorer Family – Productivity

    • Mini-report – Screen snapshots, XML file. Easily uploaded and emailed!\n
    • PQ & energy Dashboard’s for real time alarming\n
    • AnswerModules – automatic event categorization\n
    Dran-View 7 power quality analysis software\n
    • Rescue kit – Part of Dran-View 7. Correct problems with wiring, CT orientation, time errors and more\n
    • Post processing – Part of Dran-View 7. Compute harmonics and other parameters from the waveforms recorded by the instrument\n
    \n

    Measured Parameters\n

    \n

    (4) Differential Voltage: 512s/c, 16 bit resolution

    \n
      \n
    • 0-1000Vrms, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • IEC 61000-4-30 Class A: 60-1000Vrms, ±0.1 % of Udin, range of 10% – 150% of Udin
    • \n
    • Transients – rms: 0-1414Vpk, ±0.2 % of Udin
    • \n
    • Transients – High Speed: 10-2000Vpk, +/- 10% of reading, +/- 0.5% FS
    • \n
    \n

    (4) Current: 512 s/c, 16 bit resolution

    \n
      \n
    • Range (rms) probe dependent, AC/DC, +/- 0.1% reading +/- 0.05% FS
    • \n
    • Transients – Range probe dependent
    • \n
    • Transients – High Speed: Range probe dependent., 10% of Reading, +/- 0.5%FS
    • \n
    \n

    Frequency: 10 sec window

    \n
      \n
    • 16-25Hz, 41-69Hz, +/- 0.01Hz
    • \n
    \n

    Calculated Parameters

    \n

    Power/Energy – 1 Second sampling\n
    Real Power (W) – P: meets 0.2S requirements, range probe dep.\n
    Apparent Power (VA) – S: meets 0.2S requirements, range probe dep.\n
    Reactive Power (var) – Q: meets 0.2S requirements, range probe dep.\n
    Power Factor (W/VA) -”true” 1 to 0 to 1\n
    Displacement PF -1 to 0 to +1\n
    Demand (in W): meets 0.2S requirements, range probe dep.\n
    Energy (in Wh): meets 0.2S requirements, range probe dep.

    \n

    Distortion – 200ms, 3 sec, 10 min windows\n
    Vthd: 0-100%, +/- 5% for V>=1% Vnom,\n
    V Ind Harm: DC, 2-127, +/- 5% for V>=1% Vnom\n
    Ithd: 0-100%, +/- 5% for V>=1% Vnom,\n
    I Ind Harm: DC, 2-63, +/- 5% for V>=1% Vnom

    \n

    Misc.\n
    Pst – 10 minutes: 0.2-10, +/- 0.05 @ Pst=1 (50/60Hz only)\n
    Plt – 2 hours: 0.2-10, +/- 0.05 @ Pst=1 (50/60Hz only)

    \n

    Standards Compliance

    \n

    Power Quality IEC 61000-4-30 Class A: Edition 2 (2008)
    I
    EEE 1159: 2009

    \n

    Power\n
    IEEE 1459: 2000

    \n

    Harmonics\n
    IEC 61000-4-7 Class 1: Edition 2 (2008)

    IEEE 519: 2014\n

    Voltage Flicker\n
    IEC 61000-4-15: Edition 2 (2010)\n
    IEEE 1453: 2011

    \n

    Compliance/Testing\n
    EN 50160: 2010

    \n

    General Specifications\n

    \n

    Dranetz HDPQ Xplorer SP (IP65)\n

    \n
      \n
    • Size: (11″w x 6.5″h x 2.5″d), (27.9cm x 16.5cm x 6.4cm)
    • \n
    • Weight: 3.8lbs, 1.72kg
    • \n
    • Operating temperature: -10 to 50 deg C (14 to 122 deg F)
    • \n
    • Storage temperature: -40 to 85 deg C (-40 to 185 deg F)
    • \n
    • Humidity: 10-90% non condensing
    • \n
    • Power Supply: 90-600VAC/500VDC (50/60Hz). Powered by the phase being measured, or other source
    • \n
    \n

    Clock accuracy and resolution\n

    \n
      \n
    • Internal: +/- 1 sec/day at 25 deg C
    • \n
    • NTP: +/-10 msec
    • \n
    • GPS: +/-1 msec
    • \n
    \n

    AC Adapter: 100-240Vac 50/60Hz
    Battery capacity and charge time:
    \n

    \n
      \n
    • Dranetz HDPQ Xplorer SP: 30 minutes run time on full charge, 3 hours charge time
    • \n
    \n

    Memory size: 4GB\n
    \n

    \n

    Communications

    \n

    Ethernet, 802.11 b/g/n Wireless (available without Wi-Fi as a special order)
    USB On the Go
    Bluetooth via USB adapter
    VNC remote control
    Android & Apple App

    \n

    Ease of Use Features

    \n

    Automatic Setups – Start monitoring in seconds!\n
    Pre-programmed monitoring modes – Pre-configured setups for various applications\n
    AnswerModules®– Sag/Dip directivity, PF Cap, Motor\n
    Dashboards – Power Quality, Demand & Energy – Immediately know when events have been recorded\n
    Simultaneous Power Quality, Demand & Energy monitoring\n
    Mini-Report – Take screen snapshots that can be uploaded to your computer and included in reports, attached to emails, etc.Power the instrument from the circuit being measured, or another source (SP Only)

    \n
    \n

    Datasheet - Dranetz - HDPQ Xplorer \n

    \n
    \n

    Datasheet - Dranetz - HDPQ-SP Weatherproof Packages\n

    \n
    ", "catalogId": 312399, "id": 11151129, "name": "Dranetz - HDPQ Xplorer SP - (Rated IP65) Transients to 1us, 4 transient triggers", "url": "/industries-1/electrical-utility/dranetz-hdpq-xplorer-transients-to-1us-4-transient-triggers", "title": "", "smallImage": "/_assets/images/product/HDPQ-SPXplorer-resized-1.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-SPXplorer-resized-1.jpg", "largeImage": "/_assets/images/product/HDPQ-SPXplorer-resized-1.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-SPXplorer-resized-1.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "HDPQ-SPX4AFLEX3KPKG - SP", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/industries-1/electrical-utility/dranetz-hdpq-xplorer-transients-to-1us-4-transient-triggers", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - DRANFLEX Flexible Probes 3000A, 6000A (24

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
    \n

    Dranetz Flexible Probes are available in three lengths 24 inches, 36 inches, and 48 inch lengths and available in two maximum ranges of 3000 A RMS and 6000 A RMS.

    \n

    Each probe can be powered by battery or AC adapter and multiple probes can be powered by a single AC adapter. Flex probes are available as separate probes, or as four phase packages, which include the power supply. All Flexible Probes listed here are compatible with Dranetz portable power quality monitors: Dranetz HDPQ®, PowerXplorer , PowerGuide, PowerVisa, PowerGuia, Energy Platform, PP4300, 658 with CA4300 adapter; and Dranetz permanent power quality instruments: Encore 61000 with 61MAC module, Signature System 5513. Adapters are available for use with other instrument configurations; contact us for details. Dranetz recommends only Dranetz-brand probes be used with Dranetz power quality analyzers.

    \n
    \n
    \n

    Single Phase Flexible Probes

    \n
      \n
    • DRANFLEX3000XLB24 30/300/3000A, 24” FLEX PROBE
    • \n
    • DRANFLEX3000XLB36 30/300/3000A, 36” FLEX PROBE
    • \n
    • DRANFLEX3000XLB48 30/300/3000A, 48” FLEX PROBE
    • \n
    • DRANFLEX6000XLB24 60/600/6000A, 24” FLEX PROBE
    • \n
    • DRANFLEX6000XLB36 60/600/6000A, 36” FLEX PROBE
    • \n
    • DRANFLEX6000XLB48 60/600/6000A, 48” FLEX PROBE
    • \n
    • Frequency range 10Hz...10kHz
    • \n
    • Max. diameter of measured cord 8/11/17 inch diameter
    • \n
    \n

    Three Phase Flexible Probes

    \n
    \n
      \n
    • DRANFLEX3003XLB24    30/300/3000A, 24” FLEX PROBE  \n
    • \n
    • DRANFLEX3003XLB36    30/300/3000A, 36” FLEX PROBE    \n
    • \n
    • DRANFLEX3003XLB48    30/300/3000A, 48” FLEX PROBE    \n
    • \n
    • DRANFLEX6003XLB24    60/600/6000A, 24” FLEX PROBE    \n
    • \n
    • DRANFLEX6003XLB36    60/600/6000A, 36” FLEX PROBE    \n
    • \n
    • DRANFLEX6003XLB48    60/600/6000A, 48” FLEX PROBE
    • \n
    • Frequency range 10Hz...10kHz 
    • \n
    • Max. diameter of measured cord 8/11/17 inch diameter
    • \n
    \n

     

    \n

    Four Phase Packages

    \n

    Flex3K24PKG 30/300/3000 24″ Probe\n
    Includes (1) 3-phase Flex, (1) single-phase Flex, and ISOFLEX-MHXL4P Power Supply.

    \n

    Flex3K36PKG 30/300/3000 36″ Probe\n
    Includes (1) 3-phase Flex, (1) single-phase Flex, and ISOFLEX-MHXL4P Power Supply.

    \n

    Flex3K48PKG 30/300/3000 48″ Probe\n
    Includes (1) 3-phase Flex, (1) single-phase Flex, and ISOFLEX-MHXL4P Power Supply.

    \n

    Flex3K24PKG 60/600/6000 24″ Probe\n
    Includes (1) 3-phase Flex, (1) single-phase Flex, and ISOFLEX-MHXL4P Power Supply.

    \n

    Flex3K36PKG 60/600/6000 36″ Probe\n
    Includes (1) 3-phase Flex, (1) single-phase Flex, and ISOFLEX-MHXL4P Power Supply.

    \n

    Flex3K48PKG 60/600/6000 48″ Probe\n
    Includes (1) 3-phase Flex, (1) single-phase Flex, and ISOFLEX-MHXL4P Power Supply.

    \nDranetz - Accessory Catalog \n
    \n

     

    \n

     

    \n

     

    \n
    \n
    ", "catalogId": 317853, "id": 11151335, "name": "Dranetz - DRANFLEX Flexible Probes 3000A, 6000A (24\", 36\", 48\")", "url": "/Products/power-analysers/Accessories/dranetz-power-quality-analyser-accessories/sonel-f-1a-flexible-clamps-3000a--360-mm-1200mm-long-1", "title": "AEMC - 193-24-30 Ampflex Transducers (Set of 3)", "smallImage": "/_assets/images/product/Dranetz-flexible-probes_600x600.jpg", "smallImageUrl": "/_assets/images/product/Dranetz-flexible-probes_600x600.jpg", "largeImage": "/_assets/images/product/Dranetz-flexible-probes_600x600.jpg", "largeImageUrl": "/_assets/images/product/Dranetz-flexible-probes_600x600.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "DRANFLEX3003XLB24", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/Accessories/dranetz-power-quality-analyser-accessories/sonel-f-1a-flexible-clamps-3000a--360-mm-1200mm-long-1", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - Dran-View 7 Software

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "

    DRAN-VIEW 7\n
    \n

    \n

    Windows Based Power Quality Software Package

    \n

    DRAN-VIEW 7 software is a Windows based software package that enables power professionals to simply and quickly visualize and analyze power and energy\n monitoring data. It is a snap to navigate, delivers automated functionality, and incorporates powerful analytical capabilities and customizable options\n to meet the needs of each individual user. Dran-View is successfully used by thousands of customers around the world, and has become the industry leading\n power management software tool. 

    \n

    Description\n
    \n

    \n

    Detailed analysis of Power Quality and/or Energy data from nearly any recent products from Dranetz. These are not just screen captures, this is an advanced\n analysis of sample points recorded and saved by your Dranetz instrument, and presented in various forms including Time Plots, Event Lists, and Event\n detail. Due to the advanced design of the Dranetz event database Time Plots and Event Detail graphs can be zoomed in to get to the detailed information.\n
    \n

    \n
      \n
    • A simple mouse click allows you to quickly scroll through data, zoom in on disturbances, trend data, filter events, evaluate statistics, and perform\n advanced harmonic and interharmonic analyses.
    • \n
    • The software has been optimized for speed and to accommodate large data sets.
    • \n
    • Flexibility has been integrated throughout the package—users can customize both appearance and behavior.
    • \n
    • Two versions are available—one for the everyday user (Pro), the second for advanced power professionals (Enterprise).
    • \n
    • Multi-functional Dran-View helps you make the most of complex data, so that you can spend time where it counts most—evaluating, troubleshooting\n and preventing power quality events.
    • \n
    \n

    DRAN-VIEW 7 software runs on your Windows operating system. The data file is read by the PC via memory card / reader or direct connect interface. Launch\n Windows and simply select File>Open and locate the data file you wish to analyze.

    \n

    Features\n
    \n

    \n

    Speed – Significantly faster waveform calculations and file loading. \n
    \n

    \n

    Memory – Support for large data files. Effects file-compression (half-size of the original data) when saving DV6 documents.\n
    New User Interface – Improved zoom and pan functions, drag and drop charts, insert pictures and photos, customize toolbars, and more.\n
    Flexibility – Customizable report presentations and math functions in a wide variety of situations.\n
    Undo/Redo – Has an unlimited Undo/Redo queue.\n
    Built-in word processor – Features an internal word processor. Edit reports as they are generated, embed text documents within Dran-View\n files, and more.\n
    Improved scaling of harmonics – Use separate harmonic scaling for voltage, current, and power parameters. For convenience, there’s\n only one setting across the document. Re-scales instrument as well as calculated harmonics.\n
    Improved Format Templates – Format templates provide consistency in layout and format.\n
    Web Updates – Automatic updates available via Internet.

    \n

    Enhancements for the Enterprise edition only:

    \n
      \n
    • Presentation of up to 16 simultaneous data sets emanating from different instrument models. This allows comparison of data from different sources in\n the same chart. Performs mathematical calculations across sites.
    • \n
    • Supports an unlimited number of presentation aides such as charts, statistical tables, and phasors in each window.
    • \n
    • Uses simple, intuitive drag-and-drop function to manipulate screen items.
    • \n
    • Supports a Harmonics/Timeplots Calculator for all file types resulting in more accurate harmonic calculations, more parameter calculations, etc.
    • \n
    • Allows fast and painless creation of print-queues or restore program states.
    • \n
    • Features an improved point-and-click formula editor.
    • \n
    • Reads IEEE C37.111-1991/1999 COMTRADE and TXT/CSV data files.
    • \n
    \n

    \n

    Click Here for Datasheet - Introducing Dran-View 7 \n

    \n

    Click Here for Datasheet - Overview of Dran-View7 \n
    \n

    ", "catalogId": 312693, "id": 10461829, "name": "Dranetz - Dran-View 7 Software", "url": "/Products/power-analysers/power-quality-software/dranetz-dran-view-7", "title": "", "smallImage": "/_assets/images/product/Dran-View7Logo1.jpg", "smallImageUrl": "/_assets/images/product/Dran-View7Logo1.jpg", "largeImage": "/_assets/images/product/Dran-View7Logo1.jpg", "largeImageUrl": "/_assets/images/product/Dran-View7Logo1.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "DV7P-PX", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/power-quality-software/dranetz-dran-view-7", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ-DN Advanced Power Quality Instruments

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "

    Dranetz HDPQ-DN –Enhanced Dranetz HDPQ Monitoring Technology for Fixed Systems\n

    \n

    Includes DNP3 communications and fully compliant with IEC 61000-4-30 Edition 3 Class A\n
    \n

    \n

    The Dranetz HDPQ DataNode (HDPQ-DN) takes our industry leading Dranetz HDPQ monitoring and communications technology to fixed systems. Building on the Dranetz HDPQ Portable and SP instruments, the HDPQ-DN is the 3rd instrument in the Dranetz HDPQ family. The HDPQ-DN is perfect for your new system, or as an upgrade or replacement for the 61000 (61STD), and is fully compatible with PQView DE (supersedes ESS), PQView® and Dran-View 7 software.   \n
    \n

    \n

    4 models available to meet any circuit connection need  \n
    \n

    \n

    IEC 61000-4-30 Edition 3 Class A compliant\n
    Add to existing Encore Systems, or as a 61000 upgrade/replacement\n
    Direct replacement for the 61000 (61STD) – Reuse all mounting hardware, pods, etc.\n
    Instrument call back\n
    PQDIF data storage\n

    \n

    SPECIFICATIONS\n
    \n

    \n
    \n

    VOLTAGE

    \n
      \n
    • Channels: (4), differential inputs, AC/DC
    • \n
    • Sampling: 512 samples/cycle, 16 bit A/D, synchronous sampling
    • \n
    • Range: 1-600 Vac/dc
    • \n
    • Full Scale Accuracy: 0-600V, +/-0.1% of reading, <40V +/-0.5%FS
    • \n
    • Frequency: 16/20Hz, 50Hz, 60Hz
    • \n
    • Harmonics: Per IEC 61000-4-7, individual harmonics to the 127th
    • \n
    • Input impedance: 10MΩ to ground
    • \n
    \n
    \n

    CURRENT

    \n
      \n
    • Channels: (4), differential inputs, AC/DC
    • \n
    • Sampling 512 samples/cycle, 16 bit A/D
    • \n
    • Range: Model & CT dependent. 1.5Vrms FS, 5A or 1A
    • \n
    • Accuracy: 0.1% reading. Does not include CT
    • \n
    • Harmonics: Per IEC 61000-4-7, individual harmonics to the 63rd
    • \n
    \n

    DIGITAL INPUT (optional)

    \n
      \n
    • Range: 0 – 200VDC
    • \n
    • 1KHZ sampling, Edge or level triggered,
    • \n
    • Logic programmed by user (active high or active low)
    • \n
    • Time stamped to the millisecond
    • \n
    • Screw terminals
    • \n
    \n

    MODELS AVAILABLE

    \n
      \n
    • HDPQ-DN-MVS: Screw terminals for voltage and current
    • \n
    • HDPQ-DN-MZP: Pod connections for use with Dranetz voltage and current pods
    • \n
    • HDPQ-DN-MVB: Safety connectors for voltage, Dranetz TR connectors for Flex and clamp-on CT’s
    • \n
    • HDPQ-DN-MVSTR: Screw terminals for voltage, Dranetz TR connectors for Flex and clamp-on CT’s
    • \n
    \n

    MEMORY

    \n
      \n
    • 4GB internal flash
    • \n
    \n

    MONITORING COMPLIANCE

    \n
      \n
    • IEC61000-4-30 Edition 3 Class A, IEC61000-4-7, IEC61000-4-15
    • \n
    • EN50160, NVE, IEEE1159, IEEE1453, IEEE519:2014
    • \n
    \n

    COMMUNICATIONS

    \n
      \n
    • Standard: RJ45 TCP/IP Ethernet, USB
    • \n
    • Optional: 3G/4G cellular
    • \n
    • Protocols: XML, Modbus TCP
    • \n
    • Time synchronization: NTP, optional internal GPS or IRIG-B
    • \n
    \n
     
    \n\n
     
    \n\n
    ", "catalogId": 295103, "id": 11099318, "name": "Dranetz - HDPQ-DN Advanced Power Quality Instruments", "url": "/Products/power-analysers/permanent-monitoring/dranetz-hdpq-dn", "title": "", "smallImage": "/_assets/images/product/HDPQ-DN-3-4_600px.png", "smallImageUrl": "/_assets/images/product/HDPQ-DN-3-4_600px.png", "largeImage": "/_assets/images/product/HDPQ-DN.png", "largeImageUrl": "/_assets/images/product/HDPQ-DN.png", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "HDPQ-DN", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/permanent-monitoring/dranetz-hdpq-dn", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - PQView DE Software for Permanent Systems

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "

    PQView DE – Power Quality Analysis Software for Dranetz Instruments\n
    \n

    \n

     

    \n

    Intelligent, Web-Enabled Power Quality Analysis Software

    \n

    \"PQView

    \n
    \n
    \n

    PQView DE, Dashboard View 

    \n
    \n

    PQView DE is web browser based, advanced, intelligent software that is both the user interface and system controller for your entire Dranetz power\n monitoring system. PQView DE automatically communicates with each instrument in the monitoring system, downloads and stores the data and presents\n information in an easy to use web browser based interface. PQView DE can be used in any application, from small systems with a few monitoring points\n to very large multi-point, facility or utility wide monitoring systems.

    \n

    Additionally, PQ ViewDE is the ideal software solution for both existing users of Encore Series Software, and new Dranetz Fixed Monitoring Systems!

    \n
    \n

    Why Choose PQView DE?

    \n

    PQView DE is the ideal software for both new Dranetz customers, as well as existing Encore Series Software (ESS) users. Why? Click the + in the accordions\n below to view a list of PQView DE features and benefits.

    \n

    Upgrade from ESS Software\n
    \n

    \n
    \n
    • ESS has been discontinued and is no longer supported by Dranetz\n
    • ESS uses Java plug-ins that are no longer supported by their manufacturer (Oracle) and most web browsers\n
    • Seamless upgrade to PQView DE\n
    • PQView DE supports the same Dranetz instruments as ESS\n
    • Import your ESS settings & database to PQView DE\n
    • All of the benefits of the new applications\n
    • ESS used a USB HASP license – PQView DE uses a modern electronic license
    \n

    \n
    New Dranetz Fixed Systems Applications\n
    \n

    • PQView DE is new, modern software that will continue to be enhanced & supported in the future \n
    \n

    \n
    • Windows 7, 8, and 10 compatible server software\n
    • Fully web browser enabled multi-user interface – no user/client licenses required\n
    • View information using virtually any desktop, laptop, tablet and smartphone\n
    • Responsive web design that adjusts the display to the screen size of the device being used\n
    • View information on devices running Windows, Android or IOS\n
    • Manages your Dranetz fixed monitoring system – automatically communicates with each instrument, downloads data for viewing using a web browser\n
    • Compatible with all current and most legacy Dranetz fixed instruments\n
    • Easily view trends, events, repots and real time data from anywhere with connectivity to the monitoring system\n
    • Interactive charts – Zoom, pan and export data using a web browser\n
    • Seamlessly upgrade to PQView as your needs grow
    \n
    \n

    Now is the Perfect Time to Upgrade to PQView DE\n

    \n

    Oracle, Java’s manufacturer, has announced that it has ended development of the Java Plug-In for Web browsers. In addition, the latest generation web\n browsers no longer support the plug-in architecture that is required to use the Java Plug-In. Therefore, automated software updates, and free system\n support for our legacy, Encore Series Software (ESS), will be discontinued as PQView DE replaces ESS.

    \n

    Powerful Web Browser User Interface

    \n

    \n \"PQViewDE-Device-Accessibility\" PQView DE has an easy to use, password-protected web browser interface that allows for multi-user access to your monitoring system from\n any computing device for any authorized user with access to the communications network. Trends, data lists, real-time views, reports and setups\n are just a few clicks away. Plus, information can be easily shared and exported to Word, Excel, PQView and other software packages. PQView DE can\n also notify you via text or email of PQ or other events that have occurred.

    \n
      \n
    • Versatile – PQView DE is supported across a wide range of platforms and device configurations, such as a PC, MAC, Android/Apple\n tablet or smartphone
    • \n
    • Accessible – PQView DE can be used with nearly any web browser of your choice, including: Internet Explorer, Edge, Safari, Chrome\n or Firefox.
    • \n
    • Responsive – The dynamic web design of PQViewDE means that information is automatically sized to the screen size of device being\n used to browse the monitoring system.
    • \n
    • Customizable– PQView DE can be programmed to send users alert messages, via SMS (text message) or email, based on a variety of\n power quality events.
    • \n
    \n

    Incredibly Intelligent Power Quality Analysis

    \n

    The combined knowledge of Dranetz and its sister company, Electrotek Concepts, gives our monitoring systems the intelligence to perform advanced characterization\n of PQ events. You receive a clear and simple explanation of an event with in-depth analysis. Unique AnswerModules® perform advanced analysis and\n provide answers to more difficult power quality events through an intuitive user interface. Answer Modules interpret data, making every user an\n expert. Answer Modules are available for every industry and include: Sag Directivity, PF Correction Capacitor detection/directivity.

    \n

    System Software For All Applications, Large & Small – Today & Tomorrow

    \n

    System software for communications, visualization and reporting is a key component of any fixed monitoring system. PQView DE, the standard offering\n from Dranetz is for use with all Dranetz systems products, including the HDPQ DataNode, 61000 series, Signature System, ES2xx meters, and others.

    \n

    PQView DE is a derivative of our PQView software. As your needs grow, PQView DE users have a seamless upgrade path to the more powerful PQView® software\n which is intended for larger applications, applications that include other manufacturers products, or those that require enterprise software. PQView\n enables users to organize data from a variety of instruments, such as power quality monitors, microprocessor relays, and digital fault recorders.\n It also stores site characteristics (e.g., substation, bus, feeder, latitude, longitude, etc.) and event information for voltage sags, transients,\n and faults (e.g., root cause code or text description). PQView brings all this information together in one relational database and provides the\n means to automate both the loading of new data and the generation of monitoring reports.

    \n
    \"PQViewDE-Network-Graphic\"
    \n
    \n

     

    \n
    ", "catalogId": 312693, "id": 11099329, "name": "Dranetz - PQView DE Software for Permanent Systems", "url": "/Products/power-analysers/power-quality-software/dranetz-pqview-de", "title": "", "smallImage": "/_assets/images/manufacturer/Dranetz logo.jpg", "smallImageUrl": "/_assets/images/manufacturer/Dranetz logo.jpg", "largeImage": "/_assets/images/manufacturer/Dranetz logo.jpg", "largeImageUrl": "/_assets/images/manufacturer/Dranetz logo.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "PQView DE", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/power-quality-software/dranetz-pqview-de", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - ENCORE - Advanced Power Quality Instruments

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Permanently Installed Power Quality Monitoring System
    • \n
    \n
      \n
    • Protect Your Infrastructure

       

       

      Dranetz was a first to pioneer permanently installed or fixed power quality monitoring systems. Our industry leading web browser based permanent monitoring system includes the Dranetz HDPQ Power Quality DataNode, the 61000 family (61STD, 61SG, 61SGD) of Power Quality instruments and our ES series family of Demand and Energy meters. All are fully compatible with PQView® DE (supersedes ESS) and PQView web enabled system software.

      The Dranetz HDPQ DataNode (HDPQ-DN) takes our industry leading Dranetz HDPQ monitoring and communications technology to fixed systems. Building on the Dranetz HDPQ Portable and SP instruments, the HDPQ-DN is the 3rd instrument in the Dranetz HDPQ family. The HDPQ-DN is perfect for your new system, or as an upgrade or replacement for the 61000 (61STD), and is fully compatible with PQView DE (supersedes ESS), PQView® and Dran-View 7 software.

      The 61000 family (61STD, 61SG, 61SGD) of PQ instruments is the first completely modular and configurable instrument to shatter the traditional 8-channel (4 voltage/4 current) instrument format. You can have your choice of voltage, current and data digital input modules to build from one to four instruments in a single compact, cost-effective format. Uniquely designed with a modular chassis platform, these instruments can be completely customized to meet each specific monitoring application.

      Our ES230, ES230s, ES210, ES220 family of demand and energy meters round out Encore Series’ power monitoring capabilities by providing a complete power monitoring solution. Our system software, PQView DE automatically collects data from all instruments in your monitoring system in an easy to use, web browser based operating environment, allowing multiple users to simultaneously see data in real time, trend historical information, produce reports and even intelligently analyze data using our unique Answer Modules®. Whether your application requires demand and energy monitoring, power quality monitoring or both, Dranetz can meet your fixed system needs.

    • \n
    \n
     \n
    \n\n

    \n
    \n", "catalogId": 295103, "id": 10386223, "name": "Dranetz - ENCORE - Advanced Power Quality Instruments", "url": "/Products/power-analysers/permanent-monitoring/dranetz-encore", "title": "", "smallImage": "/_assets/images/product/EncoreInfrastructure.jpg", "smallImageUrl": "/_assets/images/product/EncoreInfrastructure.jpg", "largeImage": "/_assets/images/product/PermanentPQMonitors.png", "largeImageUrl": "/_assets/images/product/PermanentPQMonitors.png", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "ENCORE-SW", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/permanent-monitoring/dranetz-encore", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - PQView Software for Database Systems

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "

    Electrotek PQVIEW\n
    \n

    \n

    Electrotek PQView® is a software that expands the capabilities of Dranetz Encore Series and/or manage multiple monitoring systems. Developed by Electrotek Concepts, PQView is a database software application designed to store and analyze large quantities of power quality-related disturbance and steady-state measurement data from hundreds of monitoring points. Featuring data management tools that can quickly characterize this data, PQView includes statistical analysis and plotting tools that can provide single or multiple-site analysis of power systems. Encore Series, Signature System, PQNode family, Dranetz portable instruments, IEEE PQDIF, IEEE COMTRADE and many non Dranetz meters are PQView compatible.

    \n

     

    \n
    \n
    \n
    \n
    \n
    \n
    \n
    \n
    \"PQView
    \n
    \n
    \n
    \n
    \n
    \n
    \n
    Description
    \n
    \n

    PQView® is a multi-component software system developed by Electrotek Concepts® and EPRI® for building and analyzing databases of power, power quality,\n and energy measurements, and available for use with Dranetz Encore instrument configurations. PQView integrates data from microprocessor relays,\n digital fault recorders, power quality monitors, smart meters, and SCADA historians into an open relational database.\n
    PQView Fault Analysis Modules automatically combine electric power systems recordings with data from SCADA, GIS, and network topology to provide\n estimated fault location and to send an alarm to the operations personnel, reducing time to locate faults by hours.

    \n
      \n
    • Reduce Time to Locate Faults
    • \n
    • Reduce Time to Classify Fault Types
    • \n
    • Reduce Fault Duration
    • \n
    \n

    PQView Report Writing Modules prepares industry standard reports or custom reports. These reports can automatically document compliance with local\n regulations and standards.

    \n

    PQView Answer Modules® automatically assess the health and direction of capacitor switching, record reactive power changes, and the direction of\n voltage sags.

    \n

    PQView combines powerful features in a user-friendly interface. Measurements can be stored in either Microsoft® Access or Microsoft SQL Server.\n A complete PQView system consists of three main applications: the Power Quality Data Manager (PQDM), the Power Quality Data Analyzer (PQDA),\n and PQWeb®.

    \n

    Find out more at www.pqview.com

    \n

    Features

    \n

    PQ Data Manager (PQDM)

    \n

    PQDM automatically builds power quality databases from data sources. It also automatically sends email notifications using SMTP servers or Microsoft\n Outlook clients when data sources have finished importing, rms voltage variations are imported from data sources, or measurements are not collected\n from a monitoring instrument for a specified period. PQDM automatically correlates measurements by time stamp and location. It also deletes\n old measurements, manually adds missed rms voltage, and performs EN 50160 or NVE 1557compliance calculations, automatic derivations, and automatic\n fault location. In addition, it can update measurement databases automatically once per day, manually, or as fast as once every minute.

    \n

    PQ Data Analyzer (PQDA)

    \n

    Steady-State Data Log Analysis

    \n

    \n \"Steady-State \n

    \n

    PQView creates trends, histograms, and statistical summary tables of more than 125 steady-state characteristics listed within the IEEE Std 1159.3-2003\n PQDIF standard. It scores charts, event lists, tables, and indices to analyze voltage sags/dips, swells, and interruptions. PQDA interfaces\n with Microsoft Word to create summary documents automatically, and allows the user to filter invalid measurements from final analysis.

    \n

    \"PQ

    \n

    PQView’s trends and histograms can be copied automatically into Microsoft Word documents, exported to HTML documents with related graphics files, or sent to a printer. PQDA creates trends, histograms, profiles, and statistics for any steady-state voltage, current, power, and energy quantity. The data for trend and histogram charts can be filtered to exclude invalid measurements. Each trend can become an event timeline by plotting any associated waveform or rms variation measurements as tick marks along the x-axis.\n
    Users can view trends and histograms for the minimum, average, maximum, standard deviation, count, and any percentile for steady-state data in intervals of minutes, hours, days, weeks, months, and years.\n
    Measurements can be normalized to one of two nominal base voltages: the base voltage set when the event was triggered, or a base voltage set for the monitoring site. Derivations from waveform samples include interactive phasor charts, spectrum charts from one- to twelve-cycle FFT and DFT transformations, filtered charts, positive-, negative-, and zero-sequence components, voltage transformations through one to four transformer connections, and IEEE P1409 missing voltage. PQDA can quickly build event lists from the millions of events recorded in a measurement database. PQView “measurement events” consist of the waveform and rms samples recorded during voltage sags and swells due to faults and motor starting, and voltage transients due to fuse operations, lightning strikes, load switching, and capacitor and cable energizing. The event lists can be built based on simple queries that only select certain meters for a specific date range. Or, they can be more sophisticated, searching for single-phase sags, three-phase sags, single-phase faults, and three-phase faults.

    \n

    RMS Voltage Variation Analysis

    \n

    \n \"PQ \n

    \n

    PQView can build ITIC Charts, CBEMA Charts, and SEMI F47 Charts, and custom charts that overlay multiple curves. Measurements from each meter can\n be plotted optionally in a different color. Because PQDA’s rms variation analysis algorithm involves temporal aggregation of multiple events\n occurring in close in time, users see the event that resulted in a particular voltage magnitude and duration, and any other events that occurred\n around the same time at that location.

    \n

    PQWeb®

    \n

    Internet Accessibility via PQWeb: PQWeb can provide data and reports via the Internet or company intranet. Through PQWeb, also available from Electrotek\n Concepts, a server runs PQView data analysis tasks and allows you to access and view the results using any web browser. With this software,\n PQView becomes a multi-platform application, able to work across otherwise incompatible operating systems.

    \n

    Specialized Functionality

    \n

    Radial and network fault location\n
    Compliance with international and national power quality standards including EuroNorm EN 50160, the Colombian Energy and Gas Regulatory Commission\n (CREG 024), and the Norwegian Water Resources and Energy Directorate (NVE 1557)

    \n
      \n
    • Voltage sag and interruption contract management
    • \n
    • Power quality event log correlation with SCADA operation logs
    • \n
    • Load forecasting
    • \n
    • Wind generation feasibility and assessment
    • \n
    \n

    For use with Dranetz Encore Series instrument configurations:

    \n

     PQView® is enterprise software available to expand the analytical capabilities of Dranetz Encore Series and/or manage multiple monitoring systems. Developed by Electrotek Concepts, PQView® is a database software application designed to store and analyze large quantities of power quality-related disturbance and steady-state measurement data from hundreds of monitoring points. Featuring data management tools that can quickly characterize this data, PQView includes statistical analysis and plotting tools that can provide single- or multiple-site analysis for power systems. Encore Series, Signature System, PQNode family, Dranetz portable instruments, IEEE PQDIF, IEEE COMTRADE and many non Dranetz meters are PQView compatible.\n

    \n


    \n

    \n

    Click Here for Brochure - PQView\n
    \n

    \n
    \n
    ", "catalogId": 312693, "id": 11099332, "name": "Dranetz - PQView Software for Database Systems", "url": "/Products/power-analysers/power-quality-software/dranetz-pqview", "title": "", "smallImage": "/_assets/images/product/PQViewLogo1200px.jpg", "smallImageUrl": "/_assets/images/product/PQViewLogo1200px.jpg", "largeImage": "/_assets/images/product/PQViewLogo1200px.jpg", "largeImageUrl": "/_assets/images/product/PQViewLogo1200px.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "PQView", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/power-quality-software/dranetz-pqview", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - PQ3K - General Purpose PQ & Energy Meter

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "

    NEWGeneral Purposed PQ Monitoring Combined with 4 Quadrant Energy Metering!\n
    \n

    \n

    The PQ3K is a cost effective monitoring solution that combines general purpose PQ detection (with waveform recording) and 4 quadrant energy monitoring in one instrument. Wide-ranging applications include utility, facility, manufacturing, petro chemical, mission critical and more. The PQ3K is housed in a 144mm x 144mm panel mounted enclosure with a high resolution, color TFT display. The PQ3K is fully compliant with IEC 61000-4-30 Edition 3 Class A for trustworthy PQ measurements. It can detect and record waveforms for sags/dips, swells, interruptions, as well as recording flicker, harmonics and more, all in parallel with complete energy metering capabilities. Digital I/O provides the ability to read alarms and provide state/condition based monitoring and alarming. IEC 61850, Modbus and Profinet are available for remote communications with 3 rd party SCADA and other monitoring systems.\n

    \n
      \n
    • Panel mounted (144mm x 144mm) PQ & Energy monitoring
    • \n
    • IEC 61000-4-30 Class A Edition 3 compliant. Independent laboratory certification
    • \n
    • PQDIF, Modbus, IEC 61850, Profinet communications
    • \n
    • State & condition based monitoring & alarming
    • \n
    • Temperature & fault current monitoring
    • \n
    • PQView DE, PQView compatible
    • \n
    \n

     

    \n

    SPECIFICATIONS\n

    \n
    \n
    \n
    \n
    \n
    \n

    INPUTS

    \n
      \n
    • Voltage\n
      Channels: (4) AC\n
      Nominal Voltage: 57.7 … 400 VLN, 100 … 693 VLL\n
      Overload capacity: 480 VLN, 832 VLL (permanent)\n
      Nominal frequency: 42 … 50 … 58 Hz, 50.5 … 60 … 69.5 Hz
    • \n
    • Current\n
      Channels: (4) AC\n
      Nominal Current: 1 … 5 A (max. 7.5 A)\n
      Overload capacity: 10 A (permanent), 100 A, 5×1 s, interval 300 s
    • \n
    • Sampling rate: 18 kHz
    • \n
    \n

    TYPES OF CONNECTIONS

    \n
      \n
    • Single phase
    • \n
    • Split phase
    • \n
    • 3 or 4-wire balanced load
    • \n
    • 3-wire balanced load [2U, 1I]
    • \n
    • 3-wire unbalanced load, Aron connection
    • \n
    • 3 or 4-wire unbalanced load
    • \n
    • 4-wire unbalanced load, Open-Y
    • \n
    \n

    I/O-INTERFACES

    \n
      \n
    • DIGITAL INPUTS PASSIVE (standard)\n
      Nominal voltage: 12/24 V DC (30 V max.)
    • \n
    • DIGITAL INPUTS ACTIVE (optional)\n
      Open circuit voltage: ≤ 15 V
    • \n
    • RELAYS (optional)\n
      Contacts: Changeover contact\n
      Load capacity: 250 V AC, 2 A, 500 VA; 30 V DC, 2 A, 60 W
    • \n
    • DIGITAL OUTPUTS 2 (standard)\n
      Nominal voltage: 12/24 V DC (30 V max.)
    • \n
    • ANALOG OUTPUTS (optional)\n
      Linearization: Linear, kinked\n
      Range: ± 20 mA (24 mA max.), bipolar\n
      Accuracy: ± 0.2 % von 20 mA\n
      Burden: ≤ 500 Ω (max. 10 V/20 mA)
    • \n
    • FAULT CURRENT MONITORING For grounded systems (optional)\n
      Number of meas. channels: 2 (2 measurement ranges each)\n
      Measurement range :1 (1A) Earth current measurement\n
      • Measuring transformer: 1/1 up to 1/1000 A\n
      • Alarm limit: 30 mA up to 1000 A\n
      Measurement range: 2 (2mA) RCM with connection monitoring\n
      • Measuring transformer: Residual current transformer 500/1 up to 1000/1 A\n
      • Alarm limit: 30 mA up to 1 A
    • \n
    • TEMPERATURE INPUTS (optional)\n
      Number of channels: 2\n
      Measurement sensor: Pt100 / PTC; 2-wire
    • \n
    \n

    INSTRUMENT POWER

    \n
      \n
    • Standard nominal voltage: 110…230 V AC, 130…230 V DC
    • \n
    • Optional nominal voltage: 24 … 48 V DC
    • \n
    • Optional nominal voltage: 110 … 200 V AC, 110 … 200 V DC
    • \n
    • Consumption: ≤ 30 VA, ≤ 13 W
    • \n
    \n
    \n
    \n
    \n
    \n

    BASIC UNCERTAINTY ACCORDING IEC/EN 60688

    \n
      \n
    • Voltage, current: ±0.1 %
    • \n
    • Power: ±0.2 %
    • \n
    • Power: factor ±0.1°
    • \n
    • Frequency: ±0.01 Hz
    • \n
    • Imbalance: U, I ±0.5 %
    • \n
    • Harmonic: ±0.5 %
    • \n
    • THD: V, I: ±0.5 %
    • \n
    • Active energy: Class 0.5S (IEC/EN 62 053-22)
    • \n
    • Reactive energy: Class 0.5S (IEC/EN 62 053-24)
    • \n
    \n

    INTERFACES

    \n
      \n
    • ETHERNET (standard)\n
      100Base TX; RJ45 socket\n
      Mode: 10/100 MBit/s, full/half duplex, auto-negotiation\n
      Protocols: Modbus/TCP, http, NTP (time synchronization)
    • \n
    • IEC61850 (optional)\n
      Ethernet 100BaseTX, RJ45 sockets, 2 ports\n
      Mode: 10/100 Mbit/s, full/half duplex, auto-negotiation. Protocol: IEC61850, NTP
    • \n
    • PROFINET IO (optional)\n
      Conformance class: CC-B\n
      100BaseTX, RJ45-Buchsen, 2 ports\n
      Mode: 10/100 Mbit/s, full/half duplex, auto-negotiation\n
      Protocol: PROFINET, LLDP, SNMP
    • \n
    • MODBUS/RTU (optional)\n
      RS-485, max. 1200 m (4000 ft)\n
      Baud rate: 9.6 to 115.2 kBaud
    • \n
    • TIME REFERENCE Internal clock\n
      Clock accuracy: ± 2 minutes/month (15 to 30°C)\n
      Synchronization via NTP server or GPS
    • \n
    \n

    ENVIRONMENTAL CONDITIONS, GENERAL INFORMATION

    \n
      \n
    • Operating temperature without UPS: –10 to +55 °C
    • \n
    • Operating temperature with UPS: 0 to +35 °C
    • \n
    • Storage temperature: –25 to +70 °C
    • \n
    • Temperature influence: 0.5 x basic uncertainty per 10 K
    • \n
    • Long-term drift: 0.5 x basic uncertainty per year
    • \n
    • Others Application group II (IEC/EN 60 688)\n
      Relative air humidity <95 % without condensation
    • \n
    • Operating altitude: ≤2000 m above NN
    • \n
    • Only to be used in buildings!
    • \n
    \n

    MECHANICAL PROPERTIES

    \n
      \n
    • Housing material: Polycarbonate (Makrolon)
    • \n
    • Flammability: class V-0 according UL94, self-extinguishing, not dripping, free of halogen
    • \n
    • Weight: 800 g
    • \n
    \n

    SAFETY

    \n
      \n
    • Current inputs are galvanically isolated from each other.
    • \n
    • Protection class II (protective insulation, voltage inputs via protective impedance)
    • \n
    • Pollution degree 2
    • \n
    • Protection IP54 (front), IP30 (housing), IP20 (terminals)
    • \n
    • Measurement category U: 600 V CAT III, I: 300 V CAT III
    • \n
    \n
    \n
    \n
    \n
    \n
    \n

    Datasheeet - Dranetz - PQ3K & PQ5K\n

    \n
    ", "catalogId": 295103, "id": 11147863, "name": "Dranetz - PQ3K - General Purpose PQ & Energy Meter", "url": "/Products/power-analysers/permanent-monitoring/dranetz-pq3k", "title": "", "smallImage": "/_assets/images/product/dranetz_pq3k-rms_edited-600x600.jpg", "smallImageUrl": "/_assets/images/product/dranetz_pq3k-rms_edited-600x600.jpg", "largeImage": "/_assets/images/product/dranetz_pq3k-edited.jpg", "largeImageUrl": "/_assets/images/product/dranetz_pq3k-edited.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "PQ3K", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/permanent-monitoring/dranetz-pq3k", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - PQ5K - General Purpose PQ & Energy Meter

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
    \n
    \n
    \n

    NEWGeneral Purposed PQ Monitoring Combined with 4 Quadrant Energy Metering!

    \n

    The PQ5K is a cost effective monitoring solution that combines general purpose PQ detection (with waveform recording) and 4 quadrant energy\n monitoring in one instrument. Wide-ranging applications include utility, facility, manufacturing, petro chemical, mission critical and\n more. The PQ5K is housed in a DIN mounted enclosure with an option for a high resolution, color TFT display. The PQ5K is fully compliant\n with IEC 61000-4-30 Edition 3 Class A for trustworthy PQ measurements. It can detect and record waveforms for sags/dips, swells, interruptions,\n as well as recording flicker, harmonics and more, all in parallel with complete energy metering capabilities. Digital I/O provides the\n ability to read alarms and provide state/condition based monitoring and alarming. IEC 61850, Modbus and Profinet are available for remote\n communications with 3rd party SCADA and other monitoring systems.

    \n
      \n
    • DIN mounted PQ & Energy monitoring
    • \n
    • IEC 61000-4-30 Class A Edition 3 compliant. Independent laboratory certification
    • \n
    • PQDIF, Modbus, IEC 61850, Profinet communications
    • \n
    • State & condition based monitoring & alarming
    • \n
    • Temperature & fault current monitoring
    • \n
    • PQView DE, PQView compatible
    • \n
    \n

    SPECIFICATIONS

    \n
    \n
    \n
    \n
    \n
    \n

    INPUTS

    \n
      \n
    • Voltage\n
      Channels: (4) AC\n
      Nominal Voltage: 57.7 … 400 VLN, 100 … 693 VLL\n
      Overload capacity: 520 VLN, 900 VLL (permanent)\n
      Nominal frequency: 42 … 50 … 58 Hz, 50.5 … 60 … 69.5 Hz
    • \n
    • Current\n
      Channels: (4) AC\n
      Nominal Current: 1 … 5 A (max. 7.5 A)\n
      Overload capacity: 10 A (permanent), 100 A, 5×1 s, interval 300 s
    • \n
    • Sampling rate: 18 kHz
    • \n
    \n

    TYPES OF CONNECTIONS

    \n
      \n
    • Single phase
    • \n
    • Split phase
    • \n
    • 3 or 4-wire balanced load
    • \n
    • 3-wire balanced load [2U, 1I]
    • \n
    • 3-wire unbalanced load, Aron connection
    • \n
    • 3 or 4-wire unbalanced load
    • \n
    • 4-wire unbalanced load, Open-Y
    • \n
    \n

    I/O-INTERFACES

    \n
      \n
    • DIGITAL INPUTS PASSIVE (standard)\n
      Nominal voltage: 12/24 V DC (30 V max.)
    • \n
    • DIGITAL INPUTS ACTIVE (optional)\n
      Open circuit voltage: ≤ 15 V
    • \n
    • DIGITAL OUTPUTS 2 (standard)\n
      Nominal voltage: 12/24 V DC (30 V max.)
    • \n
    • RELAYS (optional)\n
      Contacts: Changeover contact\n
      Load capacity: 250 V AC, 2 A, 500 VA; 30 V DC, 2 A, 60 W
    • \n
    • ANALOG OUTPUTS (optional)\n
      Linearization: Linear, kinked\n
      Range: ± 20 mA (24 mA max.), bipolar\n
      Accuracy: ± 0.2 % von 20 mA\n
      Burden: ≤ 500 Ω (max. 10 V/20 mA)
    • \n
    • FAULT CURRENT MONITORING For grounded systems (optional)\n
      Number of meas. channels: 2 (2 measurement ranges each)\n
      Measurement range: 1 (1A) Earth current measurement\n
      • Measuring transformer: 1/1 up to 1/1000 A\n
      • Alarm limit: 30 mA up to 1000 A\n
      Measurement range: 2 (2mA) RCM with connection monitoring\n
      • Measuring transformer Residual current transformer 500/1 up to 1000/1 A\n
      • Alarm limit: 30 mA up to 1 A
    • \n
    • TEMPERATURE INPUTS (optional)\n
      Number of channels: 2\n
      Measurement sensor: Pt100 / PTC; 2-wire
    • \n
    \n

    INSTRUMENT POWER

    \n
      \n
    • Standard nominal voltage: 100…230 V AC, 130…230 V DC
    • \n
    • Optional nominal voltage: 24 … 48 V DC
    • \n
    • Consumption: ≤ 27 VA, ≤ 12 W
    • \n
    \n
    \n
    \n
    \n
    \n

    BASIC UNCERTAINTY ACCORDING IEC/EN 60688

    \n
      \n
    • Voltage, current: ±0.1 %
    • \n
    • Power: ±0.2 %
    • \n
    • Power factor: ±0.1°
    • \n
    • Frequency: ±0.01 Hz
    • \n
    • Imbalance: U, I ±0.5 %
    • \n
    • Harmonic: ±0.5 %
    • \n
    • THD: V, I ±0.5 %
    • \n
    • Active energy: Class 0.5S (IEC/EN 62 053-22)
    • \n
    • Reactive energy: Class 0.5S (IEC/EN 62 053-24)
    • \n
    \n

    INTERFACES

    \n
      \n
    • ETHERNET (standard)\n
      100Base TX; RJ45 socket\n
      Mode: 10/100 MBit/s, full/half duplex, auto-negotiation\n
      Protocols: Modbus/TCP, http, NTP (time synchronization)
    • \n
    • IEC61850 (optional)\n
      Ethernet 100BaseTX, RJ45 sockets, 2 ports\n
      Mode: 10/100 Mbit/s, full/half duplex, auto-negotiation. Protocol: IEC61850, NTP
    • \n
    • PROFINET IO (optional)\n
      Conformance: class CC-B\n
      100BaseTX, RJ45-Buchsen, 2 ports\n
      Mode: 10/100 Mbit/s, full/half duplex, auto-negotiation\n
      Protocol: PROFINET, LLDP, SNMP
    • \n
    • MODBUS/RTU (optional)\n
      RS-485, max. 1200 m (4000 ft)\n
      Baud rate: 9.6 to 115.2 kBaud
    • \n
    • TIME REFERENCE Internal clock\n
      Clock accuracy: ± 2 minutes/month (15 to 30°C)\n
      Synchronization via NTP server or GPS
    • \n
    \n

    ENVIRONMENTAL CONDITIONS, GENERAL INFORMATION

    \n
      \n
    • Operating temperature without UPS: –10 to +55 °C
    • \n
    • Operating temperature with UPS: 0 to +35 °C
    • \n
    • Storage temperature: –25 to +70 °C
    • \n
    • Temperature influence: 0.5 x basic uncertainty per 10 K
    • \n
    • Long-term drift: 0.5 x basic uncertainty per year
    • \n
    • Others: Application group II (IEC/EN 60 688)\n
      Relative air humidity: <95 % without condensation
    • \n
    • Operating altitude: ≤2000 m above NN
    • \n
    • Only to be used in buildings!
    • \n
    \n

    MECHANICAL PROPERTIES

    \n
      \n
    • Housing material Polycarbonate (Makrolon)
    • \n
    • Flammability class: V-0 according UL94, self-extinguishing, not dripping, free of halogen
    • \n
    • Weight 800 g
    • \n
    \n

    SAFETY

    \n
      \n
    • Current inputs are galvanically isolated from each other.
    • \n
    • Protection class II (protective insulation, voltage inputs via protective impedance)
    • \n
    • Pollution degree 2
    • \n
    • Protection: IP54 (front), IP30 (housing), IP20 (terminals)
    • \n
    • Measurement category U: 600 V CAT III, I: 300 V CAT III
    • \n
    \n
    \n
    \n
    \n
    \n
    Datasheeet - Dranetz - PQ3K & PQ5K\n
    \n
    \n
    ", "catalogId": 295103, "id": 11147864, "name": "Dranetz - PQ5K - General Purpose PQ & Energy Meter", "url": "/Products/power-analysers/permanent-monitoring/dranetz-pq5k", "title": "", "smallImage": "/_assets/images/product/dranetz_pq5k_samples-edited-600x600.jpg", "smallImageUrl": "/_assets/images/product/dranetz_pq5k_samples-edited-600x600.jpg", "largeImage": "/_assets/images/product/dranetz_pq5k-front_edited-600x600.jpg", "largeImageUrl": "/_assets/images/product/dranetz_pq5k-front_edited-600x600.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "PQ5K", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/permanent-monitoring/dranetz-pq5k", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ VISA-VA10PKG 10A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 7 monitoring modes
    • \n
    • 100 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Bluetooth (optional) communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ VISA, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, 4x 1A to 10Arms CTs, Soft carry case, DranView 7 software
    • \n
    \n", "catalogId": 312710, "id": 10385772, "name": "Dranetz - HDPQ VISA-VA10PKG 10A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-va10pkg", "title": "", "smallImage": "/_assets/images/product/HDPQ-VA10PKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-VA10PKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-VA10PKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-VA10PKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "VBOKY351XO", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-va10pkg", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ VISA-VA500PKG 500A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 7 monitoring modes
    • \n
    • 100 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Bluetooth (optional) communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ VISA, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, 4x 10A to 500Arms CTs, Soft carry case, DranView 7 software
    • \n
    \n
     
    \n", "catalogId": 312710, "id": 10386177, "name": "Dranetz - HDPQ VISA-VA500PKG 500A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-va500pkg", "title": "", "smallImage": "/_assets/images/product/HDPQ-VA500PKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-VA500PKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-VA500PKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-VA500PKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "ZXN48F60LZ", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-va500pkg", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ VISA-VA550PKG 100A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 7 monitoring modes
    • \n
    • 100 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Bluetooth (optional) communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ VISA, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, 4x 1A to 100Arms CTs, Soft carry case, DranView 7 software
    • \n
    \n", "catalogId": 312710, "id": 10386178, "name": "Dranetz - HDPQ VISA-VA550PKG 100A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-va550pkg", "title": "", "smallImage": "/_assets/images/product/HDPQ-VA10PKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-VA10PKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-VA10PKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-VA10PKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "GAXO9K8K6Z", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-va550pkg", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ VISA-VAFLEX3KPKG 3000A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 7 monitoring modes
    • \n
    • 100 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Bluetooth (optional) communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ VISA, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, 30/300/3000A 3-phase flex probe, 30/300/3000A 1-phase\n flex probe, Soft carry case, DranView 7 software
    • \n
    \n
     
    \n", "catalogId": 312710, "id": 10386179, "name": "Dranetz - HDPQ VISA-VAFLEX3KPKG 3000A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-vaflex3kpkg-3000a", "title": "", "smallImage": "/_assets/images/product/HDPQ-VAFLEX3KPKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-VAFLEX3KPKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-VAFLEX3KPKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-VAFLEX3KPKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "4B279F2FMS", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-vaflex3kpkg-3000a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ VISA-VAFLEX6KPKG 6000A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 7 monitoring modes
    • \n
    • 100 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Bluetooth (optional) communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ VISA, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, 60/600/6000A 3-phase flex probe, 60/600/6000A 1-phase\n flex probe, Soft carry case, DranView 7 software
    • \n
    \n
     
    \n", "catalogId": 312710, "id": 10386180, "name": "Dranetz - HDPQ VISA-VAFLEX6KPKG 6000A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-vaflex6kpkg-6000a", "title": "", "smallImage": "/_assets/images/product/HDPQ-VAFLEX6KPKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-VAFLEX6KPKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-VAFLEX6KPKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-VAFLEX6KPKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "46OPJBRF59", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-vaflex6kpkg-6000a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ VISA-VAMFLEX3PKG 300A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 7 monitoring modes
    • \n
    • 100 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Bluetooth (optional) communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ VISA, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, 4x 3/30/300A 1-phase flex probes, Soft carry case, DranView\n 7 software
    • \n
    \n", "catalogId": 312710, "id": 10386182, "name": "Dranetz - HDPQ VISA-VAMFLEX3PKG 300A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-vamflex3pkg-300a", "title": "", "smallImage": "/_assets/images/product/HDPQ-VAMFLEX3PKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-VAMFLEX3PKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-VAMFLEX3PKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-VAMFLEX3PKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "7M273DYSD0", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-visa-vamflex3pkg-300a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Guide-GA10PKG 10A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Guide, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 4x 1A to 10A CTs, Soft carry case, DranView 7 software 
    • \n
    \n
     
    \n", "catalogId": 312710, "id": 10386183, "name": "Dranetz - HDPQ Guide-GA10PKG 10A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-hhhhh", "title": "", "smallImage": "/_assets/images/product/HDPQ-GA10PKG_Cropped.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-GA10PKG_Cropped.jpg", "largeImage": "/_assets/images/product/HDPQ-GA10PKG_Cropped.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-GA10PKG_Cropped.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "WPJDHQLTXD", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-hhhhh", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Guide-GA500PKG 500A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Guide, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 4x 10A to 500A CTs, Soft carry case, DranView 7 software \n
      \n
    • \n
    \n", "catalogId": 312710, "id": 10386186, "name": "Dranetz - HDPQ Guide-GA500PKG 500A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-ga500pkg-500a", "title": "", "smallImage": "/_assets/images/product/HDPQ-GA500PKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-GA500PKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-GA500PKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-GA500PKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "0YURJ7BBC7", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-ga500pkg-500a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Guide-GA550PKG 100A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Guide, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 4x 1A to 100A CTs, Soft carry\n case, DranView 7 software\n
       
    • \n
    \n", "catalogId": 312710, "id": 10386197, "name": "Dranetz - HDPQ Guide-GA550PKG 100A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-ga550pkg-100a", "title": "", "smallImage": "/_assets/images/product/HDPQ-GA10PKG_Cropped.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-GA10PKG_Cropped.jpg", "largeImage": "/_assets/images/product/HDPQ-VA10PKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-VA10PKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "OCAJOB4AV3", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-ga550pkg-100a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Guide-GAFLEX3KPKG 3000A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Guide, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 30/300/3000a 3-phase flex probes,\n 30/300/3000A 1-phase flex probe, Soft carry case, DranView 7 software\n
      \n
      \n
    • \n
    \n", "catalogId": 312710, "id": 10386199, "name": "Dranetz - HDPQ Guide-GAFLEX3KPKG 3000A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-gaflex3kpkg-3000a", "title": "", "smallImage": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "BF4J8OGM6Z", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-gaflex3kpkg-3000a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Guide-GAFLEX6KPKG 6000A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Guide, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 60/600/6000A 3-phase flex probes,\n 60/600/6000A 1-phase flex probe, Soft carry case, DranView 7 software\n
       
    • \n
    \n", "catalogId": 312710, "id": 10386200, "name": "Dranetz - HDPQ Guide-GAFLEX6KPKG 6000A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-gaflex6kpkg-6000a", "title": "", "smallImage": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "RKWRQS4U56", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-gaflex6kpkg-6000a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Guide-GAMFLEX3PKG 300A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 40 micro seconds for 50Hz
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 3 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Guide, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 4x 3/30/300A 1-phase flex probes,\n Soft carry case, DranView 7 software\n
      \n
      \n
    • \n
    \n", "catalogId": 312710, "id": 10386202, "name": "Dranetz - HDPQ Guide-GAMFLEX3PKG 300A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-gamflex3pkg", "title": "", "smallImage": "/_assets/images/product/HDPQ-GAMFLEX3PKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-GAMFLEX3PKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-GAMFLEX3PKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-GAMFLEX3PKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "CVNYRTLZBU", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-guide-gamflex3pkg", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Xplorer-XA10PKG 10A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Capture of high speed transients
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 1 micro second
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 4 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Xplorer, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 4x 1A to 10A CTs, Soft carry\n case, DranView 7 software
    • \n
    \n", "catalogId": 312710, "id": 10386212, "name": "Dranetz - HDPQ Xplorer-XA10PKG 10A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xa10pkg-10a", "title": "", "smallImage": "/_assets/images/product/HDPQ-XA10PKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-XA10PKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-XA10PKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-XA10PKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "KC6S6I65WD", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xa10pkg-10a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Xplorer-XA500PKG 500A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Capture of high speed transients
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 1 micro second
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 4 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Xplorer, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 4x 10A to 500A CTs, Soft carry\n case, DranView 7 software
    • \n
    \n", "catalogId": 312710, "id": 10386213, "name": "Dranetz - HDPQ Xplorer-XA500PKG 500A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xa500pkg-500a", "title": "", "smallImage": "/_assets/images/product/HDPQ-XA500PKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-XA500PKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-XA500PKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-XA500PKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "AYJ7Y2ZV3R", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xa500pkg-500a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Xplorer-XA550PKG 100A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Capture of high speed transients
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 1 micro second
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 4 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Xplorer, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 4x 1A to 100A CTs, Soft carry\n case, DranView 7 software
    • \n
    \n", "catalogId": 312710, "id": 10386214, "name": "Dranetz - HDPQ Xplorer-XA550PKG 100A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xa550pkg-100a", "title": "", "smallImage": "/_assets/images/product/HDPQ-XA10PKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-XA10PKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-XA10PKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-XA10PKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "PCK7KN6SLF", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xa550pkg-100a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Xplorer-XAFLEX3KPKG 3000A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Capture of high speed transients
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 1 micro second
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 4 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Xplorer, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 30/300/300A 3-phase flex probe,\n 30/300/3000A 1-phase flex probe, Soft carry case, DranView 7 software
    • \n
    \n", "catalogId": 312710, "id": 10386216, "name": "Dranetz - HDPQ Xplorer-XAFLEX3KPKG 3000A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xaflex3kpkg-3000a", "title": "", "smallImage": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "N525IXK0JA", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xaflex3kpkg-3000a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Xplorer-XAFLEX6KPKG 6000A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Capture of high speed transients
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 1 micro second
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 4 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Xplorer, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 60/600/600A 3-phase flex probe,\n 60/600/6000A 1-phase flex probe, Soft carry case, DranView 7 software
    • \n
    \n", "catalogId": 312710, "id": 10386217, "name": "Dranetz - HDPQ Xplorer-XAFLEX6KPKG 6000A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xaflex6kpkg-6000a", "title": "", "smallImage": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-GAFLEX3KPKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "8D68BI5XY6", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xaflex6kpkg-6000a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - HDPQ Xplorer-XAMFLEX3PKG 300A

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
      \n
    • Advanced power quality analyser
    • \n
    • Capture of high speed transients
    • \n
    • Large 7\" Intuitive colour screen with auto or manual set-up
    • \n
    • 4 differential AC/DC voltage channels 0-1000V
    • \n
    • 4 differential AC/DC current channels FLEX power
    • \n
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • \n
    • 512 samples/Cycle/Channel on V & I
    • \n
    • Transients to 1 micro second
    • \n
    • Sag/Dip, Swell
    • \n
    • Demand & Energy
    • \n
    • Harmonics 127/63
    • \n
    • Motor Health
    • \n
    • Automatic setups for PQ, Demand & Energy
    • \n
    • 9 monitoring modes
    • \n
    • 10,000 max pre/post tripper cycles
    • \n
    • 4 transient triggers
    • \n
    • USB, USB, Wifi, Bluetooth communication
    • \n
    • VNC for full remote control
    • \n
    • GPS TIme Synch
    • \n
    • Sag Directivity
    • \n
    • Power Factor Correction capacitor
    • \n
    • IEEE 1459 Advanced Energy
    • \n
    • IEC 6100-4-30:2008 Class A
    • \n
    • 600V CATIV
    • \n
    • 3 Year warranty
    • \n
    • Package includes: HDPQ Xplorer, AC adapter, USB cable, Keyhole mounting kit, Voltage cable set, USB-Bluetooth adaptor, 4x 3/30/300A flex probes, Soft\n carry case, DranView 7 software
    • \n
    \n", "catalogId": 312710, "id": 10386220, "name": "Dranetz - HDPQ Xplorer-XAMFLEX3PKG 300A", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xamflex3pkg-300a", "title": "", "smallImage": "/_assets/images/product/HDPQ-X4AMFLEX3PKG_CROPPED.jpg", "smallImageUrl": "/_assets/images/product/HDPQ-X4AMFLEX3PKG_CROPPED.jpg", "largeImage": "/_assets/images/product/HDPQ-X4AMFLEX3PKG_CROPPED.jpg", "largeImageUrl": "/_assets/images/product/HDPQ-X4AMFLEX3PKG_CROPPED.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "TWHW68N4H3", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-hdpq-xplorer-xamflex3pkg-300a", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - PowerGuide 4400

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
    • Advanced power quality analyser
    • Intuitive colour screen with auto or manual set-up
    • 8 channels - 4 x voltage, 4 x current
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • Fast sampling and data capture
    • AC and DC applications
    • Lightweight at 2kg
    • Removeable 4GB flash memory
    • USB and LAN communication
    ", "catalogId": 312710, "id": 10227006, "name": "Dranetz - PowerGuide 4400", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-powerguide-4400", "title": "", "smallImage": "/_assets/images/product/powerguide-4400-inst.jpg", "smallImageUrl": "/_assets/images/product/powerguide-4400-inst.jpg", "largeImage": "/_assets/images/product/powerguide-4400-inst.jpg", "largeImageUrl": "/_assets/images/product/powerguide-4400-inst.jpg", "releaseDate": "2016-10-04T23:58:03.463", "expiryDate": "9999-01-01T00:00:00", "productCode": "4400", "inStock": null, "onOrder": null, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-powerguide-4400", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - PowerVisa

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
    • Advanced 3-phase power quality analyser
    • Intuitive colour touch screen with auto or manual set-up
    • 8 channels - 4 x voltage, 4 x current
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • AC and DC applications
    • Lightweight at 2kg
    • Removeable 4GB flash memory
    • USB and LAN communication
    ", "catalogId": 312710, "id": 10227007, "name": "Dranetz - PowerVisa", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-powervisa", "title": "", "smallImage": "/_assets/images/product/dranetz-powervisa.jpg", "smallImageUrl": "/_assets/images/product/dranetz-powervisa.jpg", "largeImage": "/_assets/images/product/dranetz-powervisa.jpg", "largeImageUrl": "/_assets/images/product/dranetz-powervisa.jpg", "releaseDate": "2016-10-04T23:58:03.643", "expiryDate": "9999-01-01T00:00:00", "productCode": "PowerVisa", "inStock": null, "onOrder": null, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-powervisa", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - PowerXplorer PX5

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
    • Advanced power quality analyser
    • Intuitive colour screen with auto or manual set-up
    • 8 channels - 4 x voltage, 4 x current
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • High speed sampling and data capture
    • AC and DC applications
    • Lightweight at 2kg
    • Removeable 4GB flash memory
    • USB and LAN communication
    • 50 Hz version
    ", "catalogId": 312710, "id": 10227008, "name": "Dranetz - PowerXplorer PX5", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-powerxplorer-px5", "title": "", "smallImage": "/_assets/images/product/dranetz-powerxplorer-px5.jpg", "smallImageUrl": "/_assets/images/product/dranetz-powerxplorer-px5.jpg", "largeImage": "/_assets/images/product/dranetz-powerxplorer-px5.jpg", "largeImageUrl": "/_assets/images/product/dranetz-powerxplorer-px5.jpg", "releaseDate": "2016-10-04T23:58:03.993", "expiryDate": "9999-01-01T00:00:00", "productCode": "PX5", "inStock": null, "onOrder": null, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-powerxplorer-px5", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }
  • Dranetz - PowerXplorer PX5-400

    SALE
    {
      "moduleName": "productfeaturelist",
      "description": "
    • Advanced power quality analyser
    • Intuitive colour screen with auto or manual set-up
    • 8 channels - 4 x voltage, 4 x current
    • Measures & records power, harmonics, trends, low-medium frequency transients, events, flicker plus oscilloscope, vector diagram and statistics
    • High speed sampling and data capture
    • AC and DC applications
    • Lightweight at 2kg
    • Removeable 4GB flash memory
    • USB and LAN communication
    • Tests at 50/60Hz and 400Hz
    • 400Hz synch for shipboard & aircraft diagnostics
    ", "catalogId": 312710, "id": 10227009, "name": "Dranetz - PowerXplorer PX5-400", "url": "/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-powerxplorer-px5-400", "title": "", "smallImage": "/_assets/images/product/powerxplorer-px5-400.jpg", "smallImageUrl": "/_assets/images/product/powerxplorer-px5-400.jpg", "largeImage": "/_assets/images/product/powerxplorer-px5-400.jpg", "largeImageUrl": "/_assets/images/product/powerxplorer-px5-400.jpg", "releaseDate": "2016-10-04T23:58:04.153", "expiryDate": "9999-01-01T00:00:00", "productCode": "PX5-400", "inStock": null, "onOrder": null, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/power-analysers/portable-battery-powered/Three-Phase/dranetz-three-phase-portable-power-quality-analysers/dranetz-powerxplorer-px5-400", "globals": { "get": { "ID": "/brands/dranetz-products" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "gkjnvw15nvlff431sx5sd2cs", "ANONID_FS2805306": "21.11.2019 23:28:22.677", "ANONID2805306": "24af6516-6003-4408-8888-572a85e76747", "VISID2805306": "0f6299df-745e-4381-8f25-753035380b24#www.pacifictest.com.au#21.11.2019 23:28:22.677" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2019-11-22T10:28:22.6934134" }, "visitor": { "deviceClass": "desktop", "ip": "172.68.65.12", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (https://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=0" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } }, "params": { "tag": "Dranetz", "rowCount": "140" } }