Test your Voltage indicator is working before you prove equipment is safe to touch.
\n
\n
Many workplace regulations require you to conclusively test that your tester is working correctly BEFORE and AFTER
\n
proving that equipment is de-energised and safe to work on.
\n
\n
A convenient 240V power outlet is not always readily available in the field to test your instrument.
\n
\n
Testing on low voltage or DC such as a vehicle battery does not conclusively prove your tester is functional on AC mains.
\n
Most instruments auto select the highest range >200V AC. Proving your tester is working on the range you will use to prove safe, will maximise\n your Duty of Care.
\n
\n
\n
Proves a voltmeter is functioning correctly at a nominal 230V AC
\n
Required under WHS before proving a circuit is safe to touch
\n
Tests meter, leads and fuses at mains voltage\n
\n
Tests all multimeters & voltage testers with an input impedance > 0.5MΩ
\n
Internally self-checks that mains voltage is applied at terminals\n
\n
Indicates low battery to prevent false indication\n
Sonel P-4 is reliable, particularly durable and safe 2-pole testers, which enable testing voltage, circuit continuity and phase sequence. It has been designed for use in extreme conditions both in industry and commercial applications. Advanced technology, a high level of safety and user-friendliness are the key features of the P-line voltage testers.\n \n
\n
\n
Main functions and attributes of the P-line instruments:
\n
\n
Automatic voltage test up to 690 V AC/DC,
\n
Optical indication by a LED bar,
\n
Sound indication when dangerous voltage levels of 50 V AC and 120 V DC are exceeded,
\n
RCD trip test with switchable load,
\n
Automatic continuity test upon connection to the object,
\n
2-pole test of phase rotation direction,
\n
Single-pole indication of 100 V presence,
\n
Robust, two-component housing protecting from mechanical damages and impacts,
\n
Integrated torch light for tests in poorly lit areas,
\n
IP65 ingress protection guarantees protection against dust and water,
\n
Safety provided by measuring class compliant with CAT IV 600 V and CAT III 1000 V.
SONEL P-5 has all the features that characterize the P-4 Voltage Tester. In addition, the P-5 model has the ability to take resistance measurements\n up to 2 kΩ and has an LCD display that allows you to display the voltage and resistance values accurately.
\n
Main functions and attributes of the P-line instruments:
\n
\n
automatic voltage test up to 1000 V AC/DC,
\n
optical indication by a LED bar and additional LCD display,
\n
sound indication when dangerous voltage levels of 50 V AC and 120 V DC are exceeded,
\n
RCD trip test with switchable load,
\n
automatic continuity test upon connection to the object,
\n
2-pole test of phase rotation direction,
\n
single-pole indication of 100 V presence,
\n
resistance measurement up to 1999 Ω,
\n
HOLD function for freezing the measurement results,
\n
robust, two-component housing protecting from mechanical damages and impacts,
\n
integrated torch light and backlit display for tests in poorly lit areas,
\n
IP65 ingress protection guarantees protection against dust and water,
\n
safety provided by measuring class compliant with CAT IV 600 V and CAT III 1000 V.
SONEL P-6 has all the features that characterize the P-4 Voltage Tester and P-5 Voltage Tester. In addition, the P-6 model has the phase identification function which allows to verify the phase compatibility (and its overtaking or delay) against the phase at the reference object.\n
\n
Main functions and attributes of the P-line instruments:
\n
\n
phase identification function for verification of phase compatibility to the reference phase
\n
automatic voltage test up to 1000 V AC/DC,
\n
optical indication by a LED bar and additional LCD display,
\n
sound indication when dangerous voltage levels of 50 V AC and 120 V DC are exceeded,
\n
RCD trip test with switchable load,
\n
automatic continuity test upon connection to the object,
\n
2-pole test of phase rotation direction,
\n
single-pole indication of 100 V presence,
\n
resistance measurement up to 1999 Ω,
\n
HOLD function for freezing the measurement results,
\n
robust, two-component housing protecting from mechanical damages and impacts,
\n
integrated torch light and backlit display for tests in poorly lit areas,
\n
IP65 ingress protection guarantees protection against dust and water,
\n
safety provided by measuring class compliant with CAT IV 600 V and CAT III 1000 V.
CAT IV 1000 V IP65 Type S Voltage Absence Tester (VAT)
\n
An essential tool for electricians to check that no voltage is present before working on any electrical installation connected to the network.
\n
Compliant with IEC 61243-3 Edition 2, the C.A 771 VAT can be used to work on any 1,000 V CAT IV installation. It is rated IP65 and offers a type-S extended climatic class for indoor and outdoor use, including in extreme conditions.
\n
To meet the requirements of the standards in certain countries, this tester is available in two versions: equipped with IP2X test probes or without. The\n C.A 771 has a redundant safety system in the event of power supply faults; the ELV LED flashes when the voltage exceeds 50 VAC / 120 VDC.
\n
Safety is ensured when testing Residual Current Device (RCD) tripping by means of a double control system; both hands are necessary to press the 2 buttons\n simultaneously.
\n
The C.A 771's integrated Autotest checks the electrical circuits, the power supply, the displays and the condition of the measurement leads.
\n
Phase rotation measurement is practical, simple and quick with the 2-wire microprocessor system.
\n
Audible and visual continuity testing is provided in compliance with Appendix B of the standard. The tester can also detect stray voltages and offers unipolar\n phase identification.
\n
The test probe and leads can be removed. The C.A 753 measurement accessory (optional) can be used for quick, easy testing of European and Schuko 2P+E power\n sockets.
\n
Features\n \n
\n
\n
Full autotest
\n
Voltage Detection; LED display: 12VAC ≤ U ≤ 1000VAC; 12VDC ≤ U ≤ 1400VDC
\n
Frequency: DC, 16.67 to 800Hz
\n
Detection of stray voltages
\n
Unipolar phase detection (a single contact)
\n
Two-pole phase-sequence testing with 2-wire method
\n
Continuity test with audible and visual indication (R < 100Ω)
\n
Complies with EN 61243-3 Ed. 2009 & 2010 & IEC 61010 1000V CATIV
\n
\n
Applications
\n
\n
Detection of live and de-energized AC or DC circuits
CAT IV 1000 V IP65 two-pole Voltage Absence Tester (VAT)\n \n
\n
The C.A 773 VAT is an essential tool for electricians to check that no voltage is present before working on any electrical installation\n connected to the network.
\n
Compliant with IEC 61243-3 Edition 2, it can be used to work on any 1,000 V CAT IV, indoors or outdoors.
\n
To meet the requirements of the standards in certain countries, this tester is available in two versions: equipped with IP2X accessories or without.
\n
The C.A 773 has a backlit digital display in addition to the LEDs for viewing the measurement results.
\n
It is fitted with a redundant safety system in the event of power supply faults; the ELV LED flashes when the voltage exceeds 50 VAC / 120 VDC.
\n
The C.A 773's comprehensive Autotest checks the electrical circuits, the power supply, the displays and the condition of the measurement leads.
\n
Phase rotation measurement is practical, simple and quick with the 2-wire microprocessor system.
\n
Safety is ensured when testing Residual Current Device (RCD) tripping by means of a double control system; both hands are necessary to press the\n 2 buttons simultaneously.
\n
Audible and visual continuity testing is provided in compliance with Appendix B of the standard. The tester can also detect stray voltages and\n offers unipolar phase identification.
\n
The test probe and leads can be removed. The C.A 753 measurement accessory (optional) can be used for quick, easy testing of European and Schuko\n 2P+E power sockets.
\n
Features\n \n
\n
\n
Full autotest
\n
Voltage Detection; LED display: 12VAC ≤ U ≤ 1000VAC; 12VDC ≤ U ≤ 1400VDC
\n
Frequency: DC, 16.67 to 800Hz
\n
Detection of stray voltages
\n
Unipolar phase detection (a single contact)
\n
Two-pole phase-sequence testing with 2-wire method
\n
Continuity test with audible and visual indication (R < 100Ω)
\n
Backlit display
\n
Complies with EN 61243-3 Ed. 2009 & 2010 & IEC 61010 1000V CATIV
\n
\n
Applications
\n
\n
Detection of live and de-energized AC or DC circuits
Test your Voltage indicator is working before you prove equipment is safe to touch.
\n
\n
Many workplace regulations require you to conclusively test that your tester is working correctly BEFORE and AFTER
\n
proving that equipment is de-energised and safe to work on.
\n
\n
A convenient 240V power outlet is not always readily available in the field to test your instrument.
\n
\n
Testing on low voltage or DC such as a vehicle battery does not conclusively prove your tester is functional on AC mains.
\n
Most instruments auto select the highest range >200V AC. Proving your tester is working on the range you will use to prove safe, will maximise\n your Duty of Care.
\n
\n
\n
Proves a voltmeter is functioning correctly at a nominal 230V AC
\n
Required under WHS before proving a circuit is safe to touch
\n
Tests meter, leads and fuses at mains voltage\n
\n
Tests all multimeters & voltage testers with an input impedance > 0.5MΩ
\n
Internally self-checks that mains voltage is applied at terminals\n
\n
Indicates low battery to prevent false indication\n
Sonel P-4 is reliable, particularly durable and safe 2-pole testers, which enable testing voltage, circuit continuity and phase sequence. It has been designed for use in extreme conditions both in industry and commercial applications. Advanced technology, a high level of safety and user-friendliness are the key features of the P-line voltage testers.\n \n
\n
\n
Main functions and attributes of the P-line instruments:
\n
\n
Automatic voltage test up to 690 V AC/DC,
\n
Optical indication by a LED bar,
\n
Sound indication when dangerous voltage levels of 50 V AC and 120 V DC are exceeded,
\n
RCD trip test with switchable load,
\n
Automatic continuity test upon connection to the object,
\n
2-pole test of phase rotation direction,
\n
Single-pole indication of 100 V presence,
\n
Robust, two-component housing protecting from mechanical damages and impacts,
\n
Integrated torch light for tests in poorly lit areas,
\n
IP65 ingress protection guarantees protection against dust and water,
\n
Safety provided by measuring class compliant with CAT IV 600 V and CAT III 1000 V.
SONEL P-5 has all the features that characterize the P-4 Voltage Tester. In addition, the P-5 model has the ability to take resistance measurements\n up to 2 kΩ and has an LCD display that allows you to display the voltage and resistance values accurately.
\n
Main functions and attributes of the P-line instruments:
\n
\n
automatic voltage test up to 1000 V AC/DC,
\n
optical indication by a LED bar and additional LCD display,
\n
sound indication when dangerous voltage levels of 50 V AC and 120 V DC are exceeded,
\n
RCD trip test with switchable load,
\n
automatic continuity test upon connection to the object,
\n
2-pole test of phase rotation direction,
\n
single-pole indication of 100 V presence,
\n
resistance measurement up to 1999 Ω,
\n
HOLD function for freezing the measurement results,
\n
robust, two-component housing protecting from mechanical damages and impacts,
\n
integrated torch light and backlit display for tests in poorly lit areas,
\n
IP65 ingress protection guarantees protection against dust and water,
\n
safety provided by measuring class compliant with CAT IV 600 V and CAT III 1000 V.
SONEL P-6 has all the features that characterize the P-4 Voltage Tester and P-5 Voltage Tester. In addition, the P-6 model has the phase identification function which allows to verify the phase compatibility (and its overtaking or delay) against the phase at the reference object.\n
\n
Main functions and attributes of the P-line instruments:
\n
\n
phase identification function for verification of phase compatibility to the reference phase
\n
automatic voltage test up to 1000 V AC/DC,
\n
optical indication by a LED bar and additional LCD display,
\n
sound indication when dangerous voltage levels of 50 V AC and 120 V DC are exceeded,
\n
RCD trip test with switchable load,
\n
automatic continuity test upon connection to the object,
\n
2-pole test of phase rotation direction,
\n
single-pole indication of 100 V presence,
\n
resistance measurement up to 1999 Ω,
\n
HOLD function for freezing the measurement results,
\n
robust, two-component housing protecting from mechanical damages and impacts,
\n
integrated torch light and backlit display for tests in poorly lit areas,
\n
IP65 ingress protection guarantees protection against dust and water,
\n
safety provided by measuring class compliant with CAT IV 600 V and CAT III 1000 V.
CAT IV 1000 V IP65 Type S Voltage Absence Tester (VAT)
\n
An essential tool for electricians to check that no voltage is present before working on any electrical installation connected to the network.
\n
Compliant with IEC 61243-3 Edition 2, the C.A 771 VAT can be used to work on any 1,000 V CAT IV installation. It is rated IP65 and offers a type-S extended climatic class for indoor and outdoor use, including in extreme conditions.
\n
To meet the requirements of the standards in certain countries, this tester is available in two versions: equipped with IP2X test probes or without. The\n C.A 771 has a redundant safety system in the event of power supply faults; the ELV LED flashes when the voltage exceeds 50 VAC / 120 VDC.
\n
Safety is ensured when testing Residual Current Device (RCD) tripping by means of a double control system; both hands are necessary to press the 2 buttons\n simultaneously.
\n
The C.A 771's integrated Autotest checks the electrical circuits, the power supply, the displays and the condition of the measurement leads.
\n
Phase rotation measurement is practical, simple and quick with the 2-wire microprocessor system.
\n
Audible and visual continuity testing is provided in compliance with Appendix B of the standard. The tester can also detect stray voltages and offers unipolar\n phase identification.
\n
The test probe and leads can be removed. The C.A 753 measurement accessory (optional) can be used for quick, easy testing of European and Schuko 2P+E power\n sockets.
\n
Features\n \n
\n
\n
Full autotest
\n
Voltage Detection; LED display: 12VAC ≤ U ≤ 1000VAC; 12VDC ≤ U ≤ 1400VDC
\n
Frequency: DC, 16.67 to 800Hz
\n
Detection of stray voltages
\n
Unipolar phase detection (a single contact)
\n
Two-pole phase-sequence testing with 2-wire method
\n
Continuity test with audible and visual indication (R < 100Ω)
\n
Complies with EN 61243-3 Ed. 2009 & 2010 & IEC 61010 1000V CATIV
\n
\n
Applications
\n
\n
Detection of live and de-energized AC or DC circuits
CAT IV 1000 V IP65 two-pole Voltage Absence Tester (VAT)\n \n
\n
The C.A 773 VAT is an essential tool for electricians to check that no voltage is present before working on any electrical installation\n connected to the network.
\n
Compliant with IEC 61243-3 Edition 2, it can be used to work on any 1,000 V CAT IV, indoors or outdoors.
\n
To meet the requirements of the standards in certain countries, this tester is available in two versions: equipped with IP2X accessories or without.
\n
The C.A 773 has a backlit digital display in addition to the LEDs for viewing the measurement results.
\n
It is fitted with a redundant safety system in the event of power supply faults; the ELV LED flashes when the voltage exceeds 50 VAC / 120 VDC.
\n
The C.A 773's comprehensive Autotest checks the electrical circuits, the power supply, the displays and the condition of the measurement leads.
\n
Phase rotation measurement is practical, simple and quick with the 2-wire microprocessor system.
\n
Safety is ensured when testing Residual Current Device (RCD) tripping by means of a double control system; both hands are necessary to press the\n 2 buttons simultaneously.
\n
Audible and visual continuity testing is provided in compliance with Appendix B of the standard. The tester can also detect stray voltages and\n offers unipolar phase identification.
\n
The test probe and leads can be removed. The C.A 753 measurement accessory (optional) can be used for quick, easy testing of European and Schuko\n 2P+E power sockets.
\n
Features\n \n
\n
\n
Full autotest
\n
Voltage Detection; LED display: 12VAC ≤ U ≤ 1000VAC; 12VDC ≤ U ≤ 1400VDC
\n
Frequency: DC, 16.67 to 800Hz
\n
Detection of stray voltages
\n
Unipolar phase detection (a single contact)
\n
Two-pole phase-sequence testing with 2-wire method
\n
Continuity test with audible and visual indication (R < 100Ω)
\n
Backlit display
\n
Complies with EN 61243-3 Ed. 2009 & 2010 & IEC 61010 1000V CATIV
\n
\n
Applications
\n
\n
Detection of live and de-energized AC or DC circuits