  • AEMC - CL601 - Data Logger Clamp-on, RMS Current, 0 to 600Arms Input
    40% OFF SALE
    {tag_getquotebutton} For qoute
    {
      "moduleName": "tag_productlist_5",
      "description": "
    \n

    The Simple Logger® II Model CL601 is a battery powered, one channel recording device with an alkaline battery pack. Line tracking is performed\n such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50\n or 60Hz). Harmonic measurements are calculated from these 64 samples.\n
    The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight\n times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.\n
    The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

    \n
    \n
      \n
    • 1 channel TRMS
    • \n
    • 0 to 600A AC measurement
    • \n
    • Memory of 240,000 measurements
    • \n
    • Programmable recording length, 15 minutes to 8 weeks
    • \n
    • Alarm function
    • \n
    • Overload indication
    • \n
    • Optically isolated USB 2.0 communication
      \n
    • \n
    • DataView analysis software included
    • \n
    • 600V CAT III

    • \n
    \n", "catalogId": 287614, "id": 10226901, "name": "AEMC - CL601 - Data Logger Clamp-on, RMS Current, 0 to 600Arms Input", "url": "/Products/data-loggers/current-loggers/aemc-cl601", "title": "AEMC - CL601 - Data Logger", "smallImage": "/_assets/images/product/cl601.jpg", "smallImageUrl": "/_assets/images/product/cl601.jpg", "largeImage": "/_assets/images/product/cl601.jpg", "largeImageUrl": "/_assets/images/product/cl601.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "2126-01", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-cl601", "globals": { "get": { "CatalogueID": "287614" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "agvhl0w3gh4zgha0vk5kxt2z", "ANONID_FS2805306": "14.12.2017 05:58:10.168", "ANONID2805306": "038b0c8d-d322-4b44-9f93-cbc6ed7432fd", "VISID2805306": "138cd09f-c90c-4769-b654-200e656459bc#www.pacifictest.com.au#14.12.2017 05:58:10.168" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2017-12-14T16:58:10.1842166" }, "visitor": { "deviceClass": "desktop", "ip": "162.158.78.70", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (http://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=287614" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } } }
  • AEMC - L101 - Data logger 1-Channel, TRMS, 0 to 1VAC
    40% OFF SALE
    {tag_getquotebutton} For qoute
    {
      "moduleName": "tag_productlist_5",
      "description": "
    \n

    The Simple Logger® II Model L101 is a one channel recording device powered by an alkaline battery pack. Line tracking is performed such\n that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or\n 60Hz). Harmonic measurements are calculated from these 64 samples (Harmonics are only available from the Simple Logger® II Control Panel\n within the DataView® software).\n
    The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight\n times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.\n
    The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.\n
    Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and\n time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory\n to the computer for analysis.

    \n \n \n \n \n \n \n \n \n \n
    Features\n
      \n
    • Compatible standard current probes with voltage output and BNC connection
    • \n
    • 64 samples per cycle
    • \n
    • Programmable storage rates from 8 every second to 1 every day
    • \n
    • 3 user selectable storage modes
    • \n
    • Stores up to 240,000 measurements in non-volatile memory
    • \n
    • Powered by standard Alkaline batteries
    • \n
    • Lightweight, compact, fits anywhere
    • \n
    • 5 LED indicators quickly and clearly display Logger status
    • \n
    • Includes DataView® software for data storage, real-time waveform display, analysis and report generation
    • \n
    • Isolated USB communication
    • \n
    • 50V Cat III
    • \n
    \n
    Applications\n
      \n
    • Load profiling
    • \n
    • Fault current detection
    • \n
    • Intermittent problem detection
    • \n
    • Demand recording
    • \n
    • Neutral current monitoring
    • \n
    • Harmonic current recording using DataView® software
    • \n
    • Metering CT resizing
    • \n
    \n
    \n
    \n
    \n", "catalogId": 287614, "id": 10381627, "name": "AEMC - L101 - Data logger 1-Channel, TRMS, 0 to 1VAC", "url": "/Products/data-loggers/current-loggers/aemc-l101-1", "title": "AEMC - L101 - Data logger", "smallImage": "/_assets/images/product/L101 2126.02.jpg", "smallImageUrl": "/_assets/images/product/L101 2126.02.jpg", "largeImage": "/_assets/images/product/L101 2126.02.jpg", "largeImageUrl": "/_assets/images/product/L101 2126.02.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "L101", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-l101-1", "globals": { "get": { "CatalogueID": "287614" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "agvhl0w3gh4zgha0vk5kxt2z", "ANONID_FS2805306": "14.12.2017 05:58:10.168", "ANONID2805306": "038b0c8d-d322-4b44-9f93-cbc6ed7432fd", "VISID2805306": "138cd09f-c90c-4769-b654-200e656459bc#www.pacifictest.com.au#14.12.2017 05:58:10.168" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2017-12-14T16:58:10.1842166" }, "visitor": { "deviceClass": "desktop", "ip": "162.158.78.70", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (http://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=287614" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } } }
  • AEMC - L102 - Data Logger 2-Channel, TRMS, 0 to 1VAC
    40% OFF SALE
    {tag_getquotebutton} For qoute
    {
      "moduleName": "tag_productlist_5",
      "description": "
    \n

    The Simple Logger® II Model L102 is a two channel recording device powered by two alkaline batteries. Line tracking is performed such that\n 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or 60Hz).\n Harmonic measurements are calculated from these 64 samples (Harmonics are only available from the Simple Logger® II Control Panel within\n the DataView® software).\n
    The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight\n times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.\n
    The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.\n
    Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and\n time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory\n to the computer for analysis.

    \n \n \n \n \n \n \n \n \n \n
    Features\n
      \n
    • Compatible standard current probes with voltage output and BNC connection
    • \n
    • 64 samples per cycle
    • \n
    • Programmable storage rates from 8 every second to 1 per day
    • \n
    • 3 user selectable storage modes
    • \n
    • Stores up to 240,000 measurements in non-volatile memory
    • \n
    • Powered by standard Alkaline batteries
    • \n
    • Lightweight, compact, fits anywhere
    • \n
    • 5 LED indicators quickly and clearly display Logger status
    • \n
    • Includes DataView® software for data storage, real-time waveform display, analysis and report generation
    • \n
    • Isolated USB communication
    • \n
    • 50V Cat III
    • \n
    \n
    Applications\n
      \n
    • Split phase load monitoring
    • \n
    • Neutral and ground current monitoring
    • \n
    • Intermittent problem detection
    • \n
    • Harmonic current monitoring using DataView® software
    • \n
    • Machine load monitoring
    • \n
    \n
    \n
    \n
    \n", "catalogId": 287614, "id": 10381626, "name": "AEMC - L102 - Data Logger 2-Channel, TRMS, 0 to 1VAC", "url": "/Products/data-loggers/current-loggers/aemc-l102", "title": "AEMC - L102 - Data Logger", "smallImage": "/_assets/images/product/L102 2126.03.jpg", "smallImageUrl": "/_assets/images/product/L102 2126.03.jpg", "largeImage": "/_assets/images/product/L102 2126.03.jpg", "largeImageUrl": "/_assets/images/product/L102 2126.03.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "J4ZT9864J3", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-l102", "globals": { "get": { "CatalogueID": "287614" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "agvhl0w3gh4zgha0vk5kxt2z", "ANONID_FS2805306": "14.12.2017 05:58:10.168", "ANONID2805306": "038b0c8d-d322-4b44-9f93-cbc6ed7432fd", "VISID2805306": "138cd09f-c90c-4769-b654-200e656459bc#www.pacifictest.com.au#14.12.2017 05:58:10.168" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2017-12-14T16:58:10.1842166" }, "visitor": { "deviceClass": "desktop", "ip": "162.158.78.70", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (http://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=287614" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } } }
  • AEMC - AL834 - 4-Channel, TRMS, Bluetooth, AmpFlex® 300/3000AAC
    40% OFF SALE
    {tag_getquotebutton} For qoute
    {
      "moduleName": "tag_productlist_5",
      "description": "
    \n

    The Simple Logger® II (Bluetooth Edition) Model AL834 is a 4-channel AC current data logger with four integral flexible current sensors.\n Each sensor is 24 inches long and capable of wrapping around an 8 inch conductor.

    \n

    The AL834 has two measurement ranges of up to 300 and 3000 Amps. Both the data logger housing and the current sensors are water resistant rated to\n IP 65. A selection of data storage modes, as well as data sampling rates is user programmable through the DataView® application software\n provided. Up to 1,000,000 measurements can be stored in internal nonvolatile memory.

    \n

    The Model AL834 is powered by four C cell alkaline batteries capable of providing six months or longer recording time. Data storage rates as fast as\n 8 per second are user programmable. Communication to the DataView®software is accomplished through wireless Bluetooth technology. The\n Bluetooth adapter, provided, facilitates this communication link.

    \n

     

    \n \n \n \n \n \n \n \n \n \n
    Features\n
      \n
    • Includes four integral AmpFlex® flexible current probes that will measure up to 3000A TRMS with 0.1A resolution
    • \n
    • Dual range 300/3000A user selectable per channel
    • \n
    • 64 samples per cycle
    • \n
    • Programmable storage rates from 125ms to 1 day
    • \n
    • 4 user selectable storage modes
    • \n
    • Stores up to 1,000,000 measurements in non-volatile memory
    • \n
    • Powered by standard Alkaline batteries for a period of 180 days or more
    • \n
    • Lightweight, compact, weatherproof
    • \n
    • 6 LED indicators quickly and clearly display logger status
    • \n
    • Wireless Bluetooth communication (Bluetooth Module included)
    • \n
    • Includes FREE DataView® software for data storage, real-time waveform display analysis & report generation
    • \n
    • EN 61010-1; 600V CAT IV, 1000V CAT III
    • \n
    \n
    Applications\n
      \n
    • Single/split phase and 3 phase monitoring
    • \n
    • Neutral and ground current monitoring
    • \n
    • Intermittent problem detection
    • \n
    • Harmonic current monitoring using DataView® software
    • \n
    • Machine load monitoring
    • \n
    • Fault current detection
    • \n
    • Load profiling
    • \n
    \n
    \n
    \n

     

    \n
    ", "catalogId": 287614, "id": 10226887, "name": "AEMC - AL834 - 4-Channel, TRMS, Bluetooth, AmpFlex® 300/3000AAC", "url": "/Products/data-loggers/current-loggers/aemc-al834", "title": "", "smallImage": "/_assets/images/product/al834.jpg", "smallImageUrl": "/_assets/images/product/al834.jpg", "largeImage": "/_assets/images/product/al834.jpg", "largeImageUrl": "/_assets/images/product/al834.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "2126-14", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-al834", "globals": { "get": { "CatalogueID": "287614" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "agvhl0w3gh4zgha0vk5kxt2z", "ANONID_FS2805306": "14.12.2017 05:58:10.168", "ANONID2805306": "038b0c8d-d322-4b44-9f93-cbc6ed7432fd", "VISID2805306": "138cd09f-c90c-4769-b654-200e656459bc#www.pacifictest.com.au#14.12.2017 05:58:10.168" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2017-12-14T16:58:10.1842166" }, "visitor": { "deviceClass": "desktop", "ip": "162.158.78.70", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (http://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=287614" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } } }
  • AEMC - ML912 - 2-Channel, TRMS, MiniFlex®; 100/1000AAC
    40% OFF SALE
    {tag_getquotebutton} For qoute
    {
      "moduleName": "tag_productlist_5",
      "description": "

    \n

    The Simple Logger ® II Model ML912 is a two channel AC current recording device powered by two alkaline batteries. It incorporates two user\n selectable measurement ranges of 0 to 100 Amps and 0 to 1000 Amps. Line tracking is performed such that 64 samples over one line cycle are taken.\n Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or 60Hz). Harmonic measurements are calculated from\n these 64 samples (Harmonics are only available from the Simple Logger ® II Control Panel within the DataView ® software).\n

    \n

    The Simple Logger ® II stores TRMS values at user programmable rates of up to eight times per second. TRMS calculations are performed on\n a single line cycle. The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from\n a computer using DataView ® software.

    \n

    Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time\n information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory to the\n computer for analysis.

    \n
    \n

    \n\n \n \n \n \n \n \n \n \n
    Features\n
      \n
    • Two integral MiniFlex® flexible current sensors measure from 0.5A to 1000A
    • \n
    • 64 samples per cycle
    • \n
    • Programmable storage rates from 125ms to 1 per day
    • \n
    • 3 user selectable storage modes
    • \n
    • Stores up to 240,000 measurements in non-volatile memory
    • \n
    • Powered by standard Alkaline batteries
    • \n
    • Lightweight, compact, fits anywhere
    • \n
    • 5 LED indicators quickly and clearly display logger status
    • \n
    • Includes DataView ® software for data storage, real-time waveform display, analysis and report generation
    • \n
    • Isolated USB communication
    • \n
    • 600V CAT IV; 1000V CAT III
    • \n
    \n
    Applications\n
      \n
    • Split phase load monitoring
    • \n
    • Neutral and ground current monitoring
    • \n
    • Intermittent problem detection
    • \n
    • Harmonic current monitoring using DataView ® software
    • \n
    • Machine load monitoring
    • \n
    \n
    ", "catalogId": 287614, "id": 10226923, "name": "AEMC - ML912 - 2-Channel, TRMS, MiniFlex®; 100/1000AAC", "url": "/Products/data-loggers/current-loggers/aemc-ml912", "title": "", "smallImage": "/_assets/images/product/ml9123.jpg", "smallImageUrl": "/_assets/images/product/ml9123.jpg", "largeImage": "/_assets/images/product/ml9123.jpg", "largeImageUrl": "/_assets/images/product/ml9123.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "2126-37", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-ml912", "globals": { "get": { "CatalogueID": "287614" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "agvhl0w3gh4zgha0vk5kxt2z", "ANONID_FS2805306": "14.12.2017 05:58:10.168", "ANONID2805306": "038b0c8d-d322-4b44-9f93-cbc6ed7432fd", "VISID2805306": "138cd09f-c90c-4769-b654-200e656459bc#www.pacifictest.com.au#14.12.2017 05:58:10.168" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2017-12-14T16:58:10.1842166" }, "visitor": { "deviceClass": "desktop", "ip": "162.158.78.70", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (http://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=287614" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } } }
  • AEMC - ML914 - Current logger 4-Channel, TRMS, Bluetooth, MiniFlex® 100/1000AAC
    40% OFF SALE
    {tag_getquotebutton} For qoute
    {
      "moduleName": "tag_productlist_5",
      "description": "
    \n

    The Simple Logger® II (Bluetooth Edition) Model ML914 is a 4-channel AC current recording device powered by alkaline batteries and includes\n four integral 6\" MiniFlex® flexible current probes. The ML914 incorporates two user selectable measurement ranges of 100 and 1000 Amps.\n Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed around the nominal line frequency\n (50 or 60Hz). Harmonic measurements are calculated from these 64 samples and are only available from the Simple Logger® II Control Panel\n within the DataView®software.

    \n

    The Simple Logger® II stores TRMS at user programmable rates of up to eight times per second. TRMS calculations are performed on a single\n line cycle. The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer\n using DataView® software.

    \n

    Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time\n information Bluetooth communication provides for the transfer of data from the instrument's internal memory to the computer for analysis.

    \n \n \n \n \n \n \n \n \n \n
    Features\n
      \n
    • User selectable storage modes
    • \n
    • Up to 180 days of operation from standard alkaline batteries
    • \n
    • Stores up to 1,000,000 measurements
    • \n
    • Wireless Bluetooth data communication (Bluetooth Module included)
    • \n
    • Includes FREE DataView® software for data storage, real-time waveform display, analysis & report generation
    • \n
    • User selectable ranges up to 1000A per channel
    • \n
    • User programmable recording modes: Start/Stop, FIFO, Extended Recording Mode (XRM™) and Alarm Recording
    • \n
    • EN61010-1; EN61010-2-32; 600V CAT IV, 1000V CAT III; Protection Degree IP50 (cover closed)
    • \n
    \n
    Applications\n
      \n
    • Single/split phase and 3 phase monitoring
    • \n
    • Neutral and ground current monitoring
    • \n
    • Intermittent problem detection
    • \n
    • Harmonic current monitoring using DataView® software
    • \n
    • Machine load monitoring
    • \n
    • Fault current detection
    • \n
    • Load profiling
    • \n
    \n
    \n
    \n
    ", "catalogId": 287614, "id": 10226924, "name": "AEMC - ML914 - Current logger 4-Channel, TRMS, Bluetooth, MiniFlex® 100/1000AAC", "url": "/Products/data-loggers/current-loggers/aemc-ml914", "title": "", "smallImage": "/_assets/images/product/ml9149.jpg", "smallImageUrl": "/_assets/images/product/ml9149.jpg", "largeImage": "/_assets/images/product/ml9149.jpg", "largeImageUrl": "/_assets/images/product/ml9149.jpg", "releaseDate": "2016-10-04T00:00:00", "expiryDate": "9999-01-01T00:00:00", "productCode": "2126-4", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-ml914", "globals": { "get": { "CatalogueID": "287614" }, "cookie": { "visitorDeviceClass": "desktop", "ASP.NET_SessionId": "agvhl0w3gh4zgha0vk5kxt2z", "ANONID_FS2805306": "14.12.2017 05:58:10.168", "ANONID2805306": "038b0c8d-d322-4b44-9f93-cbc6ed7432fd", "VISID2805306": "138cd09f-c90c-4769-b654-200e656459bc#www.pacifictest.com.au#14.12.2017 05:58:10.168" }, "site": { "id": 2805306, "name": "Pacific Test Equipment", "host": "www.pacifictest.com.au", "countryCode": "AU", "language": "EN", "dateNow": "2017-12-14T16:58:10.1842166" }, "visitor": { "deviceClass": "desktop", "ip": "162.158.78.70", "country": "US", "city": "Ashburn", "userAgent": "CCBot/2.0 (http://commoncrawl.org/faq/)", "referrer": "/" }, "cart": { "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=287614" }, "user": { "entityId": 0, "firstname": "", "middleName": "", "lastname": "", "fullname": "", "username": "", "email": "", "email2": "", "email3": "", "customerType": {}, "leadSourceType": {}, "industryType": {}, "ratingType": {}, "isWholesaler": false, "isLoggedIn": false } } }
{
  "moduleName": "overallcatalog",
  "name": "Current Loggers",
  "id": 287614,
  "description": "",
  "pagination": {
    "currentPage": 1,
    "itemsPerPage": 8,
    "numberOfPages": 1,
    "totalItemsCount": 6,
    "previousPageUrl": null,
    "nextPageUrl": null
  },
  "globals": {
    "get": {
      "CatalogueID": "287614"
    },
    "cookie": {
      "visitorDeviceClass": "desktop",
      "ASP.NET_SessionId": "agvhl0w3gh4zgha0vk5kxt2z",
      "ANONID_FS2805306": "14.12.2017 05:58:10.168",
      "ANONID2805306": "038b0c8d-d322-4b44-9f93-cbc6ed7432fd",
      "VISID2805306": "138cd09f-c90c-4769-b654-200e656459bc#www.pacifictest.com.au#14.12.2017 05:58:10.168"
    },
    "site": {
      "id": 2805306,
      "name": "Pacific Test Equipment",
      "host": "www.pacifictest.com.au",
      "countryCode": "AU",
      "language": "EN",
      "dateNow": "2017-12-14T16:58:10.1842166"
    },
    "visitor": {
      "deviceClass": "desktop",
      "ip": "162.158.78.70",
      "country": "US",
      "city": "Ashburn",
      "userAgent": "CCBot/2.0 (http://commoncrawl.org/faq/)",
      "referrer": "/"
    },
    "cart": {
      "cartUrl": "/OrderRetrievev2.aspx?CatalogueID=287614"
    },
    "user": {
      "entityId": 0,
      "firstname": "",
      "middleName": "",
      "lastname": "",
      "fullname": "",
      "username": "",
      "email": "",
      "email2": "",
      "email3": "",
      "customerType": {},
      "leadSourceType": {},
      "industryType": {},
      "ratingType": {},
      "isWholesaler": false,
      "isLoggedIn": false
    }
  },
  "tag_cataloguelist_3_7": {
    "moduleName": "tag_cataloguelist_3",
    "moduleDescriptor": {
      "templatePath": "/Layouts/OnlineShop/catalogue.html",
      "parameters": "2,,,,true,true",
      "apiEndpoint": "/api/v3/tag_cataloguelist_3",
      "objectType": -1,
      "objectId": -1,
      "adminUrl": ""
    }
  },
  "tag_productlist_5_8": {
    "moduleName": "tag_productlist_5",
    "moduleDescriptor": {
      "templatePath": "/Layouts/OnlineShop/small_product.html",
      "parameters": "3,,8,,true,true",
      "apiEndpoint": "/webresources/api/v3/sites/2805306/products",
      "objectType": -1,
      "objectId": -1,
      "adminUrl": ""
    },
    "editableFieldTypes": {
      "description": "Html",
      "id": "Id",
      "name": "Text",
      "url": "Text",
      "title": "Text",
      "smallImage": "Image",
      "largeImage": "Image",
      "releaseDate": "Date",
      "expiryDate": "Date",
      "productCode": "Text",
      "inStock": "Number",
      "onOrder": "Number",
      "reorder": "Number",
      "minUnits": "Number",
      "maxUnits": "Number",
      "unitType": "Text",
      "tags": "Text",
      "custom1": "Text",
      "custom2": "Text",
      "custom3": "Text",
      "custom4": "Text",
      "isOnSale": "Boolean",
      "retailPrice": "Number",
      "salePrice": "Number",
      "wholesalePrice": "Number"
    },
    "items": [
      {
        "description": "
\n

The Simple Logger® II Model CL601 is a battery powered, one channel recording device with an alkaline battery pack. Line tracking is performed\n such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50\n or 60Hz). Harmonic measurements are calculated from these 64 samples.\n
The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight\n times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.\n
The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

\n
\n
    \n
  • 1 channel TRMS
  • \n
  • 0 to 600A AC measurement
  • \n
  • Memory of 240,000 measurements
  • \n
  • Programmable recording length, 15 minutes to 8 weeks
  • \n
  • Alarm function
  • \n
  • Overload indication
  • \n
  • Optically isolated USB 2.0 communication
    \n
  • \n
  • DataView analysis software included
  • \n
  • 600V CAT III

  • \n
\n
Click here for the Datasheet\n
\n
\n
", "catalogId": 287614, "id": 10226901, "name": "AEMC - CL601 - Data Logger Clamp-on, RMS Current, 0 to 600Arms Input", "url": "/Products/data-loggers/current-loggers/aemc-cl601", "title": "AEMC - CL601 - Data Logger", "smallImage": "/_assets/images/product/cl601.jpg", "smallImageUrl": "/_assets/images/product/cl601.jpg", "largeImage": "/_assets/images/product/cl601.jpg", "largeImageUrl": "/_assets/images/product/cl601.jpg", "releaseDate": "2016-10-04T00:00:00", "releaseDate_raw": "2016-10-03T23:00:00", "expiryDate": "9999-01-01T00:00:00", "expiryDate_raw": "9999-01-01T00:00:00", "productCode": "2126-01", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-cl601" }, { "description": "
\n

The Simple Logger® II Model L101 is a one channel recording device powered by an alkaline battery pack. Line tracking is performed such\n that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or\n 60Hz). Harmonic measurements are calculated from these 64 samples (Harmonics are only available from the Simple Logger® II Control Panel\n within the DataView® software).\n
The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight\n times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.\n
The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.\n
Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and\n time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory\n to the computer for analysis.

\n \n \n \n \n \n \n \n \n \n
Features\n
    \n
  • Compatible standard current probes with voltage output and BNC connection
  • \n
  • 64 samples per cycle
  • \n
  • Programmable storage rates from 8 every second to 1 every day
  • \n
  • 3 user selectable storage modes
  • \n
  • Stores up to 240,000 measurements in non-volatile memory
  • \n
  • Powered by standard Alkaline batteries
  • \n
  • Lightweight, compact, fits anywhere
  • \n
  • 5 LED indicators quickly and clearly display Logger status
  • \n
  • Includes DataView® software for data storage, real-time waveform display, analysis and report generation
  • \n
  • Isolated USB communication
  • \n
  • 50V Cat III
  • \n
\n
Applications\n
    \n
  • Load profiling
  • \n
  • Fault current detection
  • \n
  • Intermittent problem detection
  • \n
  • Demand recording
  • \n
  • Neutral current monitoring
  • \n
  • Harmonic current recording using DataView® software
  • \n
  • Metering CT resizing
  • \n
\n
\n
\n
\n
Click here for the Datasheet\n
\n
\n
", "catalogId": 287614, "id": 10381627, "name": "AEMC - L101 - Data logger 1-Channel, TRMS, 0 to 1VAC", "url": "/Products/data-loggers/current-loggers/aemc-l101-1", "title": "AEMC - L101 - Data logger", "smallImage": "/_assets/images/product/L101 2126.02.jpg", "smallImageUrl": "/_assets/images/product/L101 2126.02.jpg", "largeImage": "/_assets/images/product/L101 2126.02.jpg", "largeImageUrl": "/_assets/images/product/L101 2126.02.jpg", "releaseDate": "2016-10-04T00:00:00", "releaseDate_raw": "2016-10-03T23:00:00", "expiryDate": "9999-01-01T00:00:00", "expiryDate_raw": "9999-01-01T00:00:00", "productCode": "L101", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-l101-1" }, { "description": "
\n

The Simple Logger® II Model L102 is a two channel recording device powered by two alkaline batteries. Line tracking is performed such that\n 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or 60Hz).\n Harmonic measurements are calculated from these 64 samples (Harmonics are only available from the Simple Logger® II Control Panel within\n the DataView® software).\n
The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight\n times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.\n
The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.\n
Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and\n time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory\n to the computer for analysis.

\n \n \n \n \n \n \n \n \n \n
Features\n
    \n
  • Compatible standard current probes with voltage output and BNC connection
  • \n
  • 64 samples per cycle
  • \n
  • Programmable storage rates from 8 every second to 1 per day
  • \n
  • 3 user selectable storage modes
  • \n
  • Stores up to 240,000 measurements in non-volatile memory
  • \n
  • Powered by standard Alkaline batteries
  • \n
  • Lightweight, compact, fits anywhere
  • \n
  • 5 LED indicators quickly and clearly display Logger status
  • \n
  • Includes DataView® software for data storage, real-time waveform display, analysis and report generation
  • \n
  • Isolated USB communication
  • \n
  • 50V Cat III
  • \n
\n
Applications\n
    \n
  • Split phase load monitoring
  • \n
  • Neutral and ground current monitoring
  • \n
  • Intermittent problem detection
  • \n
  • Harmonic current monitoring using DataView® software
  • \n
  • Machine load monitoring
  • \n
\n
\n
\n
\n

Click here for the Datasheet
\n
\n
\n
", "catalogId": 287614, "id": 10381626, "name": "AEMC - L102 - Data Logger 2-Channel, TRMS, 0 to 1VAC", "url": "/Products/data-loggers/current-loggers/aemc-l102", "title": "AEMC - L102 - Data Logger", "smallImage": "/_assets/images/product/L102 2126.03.jpg", "smallImageUrl": "/_assets/images/product/L102 2126.03.jpg", "largeImage": "/_assets/images/product/L102 2126.03.jpg", "largeImageUrl": "/_assets/images/product/L102 2126.03.jpg", "releaseDate": "2016-10-04T00:00:00", "releaseDate_raw": "2016-10-03T23:00:00", "expiryDate": "9999-01-01T00:00:00", "expiryDate_raw": "9999-01-01T00:00:00", "productCode": "J4ZT9864J3", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-l102" }, { "description": "
\n

The Simple Logger® II (Bluetooth Edition) Model AL834 is a 4-channel AC current data logger with four integral flexible current sensors.\n Each sensor is 24 inches long and capable of wrapping around an 8 inch conductor.

\n

The AL834 has two measurement ranges of up to 300 and 3000 Amps. Both the data logger housing and the current sensors are water resistant rated to\n IP 65. A selection of data storage modes, as well as data sampling rates is user programmable through the DataView® application software\n provided. Up to 1,000,000 measurements can be stored in internal nonvolatile memory.

\n

The Model AL834 is powered by four C cell alkaline batteries capable of providing six months or longer recording time. Data storage rates as fast as\n 8 per second are user programmable. Communication to the DataView®software is accomplished through wireless Bluetooth technology. The\n Bluetooth adapter, provided, facilitates this communication link.

\n

 

\n \n \n \n \n \n \n \n \n \n
Features\n
    \n
  • Includes four integral AmpFlex® flexible current probes that will measure up to 3000A TRMS with 0.1A resolution
  • \n
  • Dual range 300/3000A user selectable per channel
  • \n
  • 64 samples per cycle
  • \n
  • Programmable storage rates from 125ms to 1 day
  • \n
  • 4 user selectable storage modes
  • \n
  • Stores up to 1,000,000 measurements in non-volatile memory
  • \n
  • Powered by standard Alkaline batteries for a period of 180 days or more
  • \n
  • Lightweight, compact, weatherproof
  • \n
  • 6 LED indicators quickly and clearly display logger status
  • \n
  • Wireless Bluetooth communication (Bluetooth Module included)
  • \n
  • Includes FREE DataView® software for data storage, real-time waveform display analysis & report generation
  • \n
  • EN 61010-1; 600V CAT IV, 1000V CAT III
  • \n
\n
Applications\n
    \n
  • Single/split phase and 3 phase monitoring
  • \n
  • Neutral and ground current monitoring
  • \n
  • Intermittent problem detection
  • \n
  • Harmonic current monitoring using DataView® software
  • \n
  • Machine load monitoring
  • \n
  • Fault current detection
  • \n
  • Load profiling
  • \n
\n
\n
\n

 

\n
", "catalogId": 287614, "id": 10226887, "name": "AEMC - AL834 - 4-Channel, TRMS, Bluetooth, AmpFlex® 300/3000AAC", "url": "/Products/data-loggers/current-loggers/aemc-al834", "title": "", "smallImage": "/_assets/images/product/al834.jpg", "smallImageUrl": "/_assets/images/product/al834.jpg", "largeImage": "/_assets/images/product/al834.jpg", "largeImageUrl": "/_assets/images/product/al834.jpg", "releaseDate": "2016-10-04T00:00:00", "releaseDate_raw": "2016-10-03T23:00:00", "expiryDate": "9999-01-01T00:00:00", "expiryDate_raw": "9999-01-01T00:00:00", "productCode": "2126-14", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-al834" }, { "description": "

\n

The Simple Logger ® II Model ML912 is a two channel AC current recording device powered by two alkaline batteries. It incorporates two user\n selectable measurement ranges of 0 to 100 Amps and 0 to 1000 Amps. Line tracking is performed such that 64 samples over one line cycle are taken.\n Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or 60Hz). Harmonic measurements are calculated from\n these 64 samples (Harmonics are only available from the Simple Logger ® II Control Panel within the DataView ® software).\n

\n

The Simple Logger ® II stores TRMS values at user programmable rates of up to eight times per second. TRMS calculations are performed on\n a single line cycle. The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from\n a computer using DataView ® software.

\n

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time\n information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory to the\n computer for analysis.

\n
\n

\n\n \n \n \n \n \n \n \n \n
Features\n
    \n
  • Two integral MiniFlex® flexible current sensors measure from 0.5A to 1000A
  • \n
  • 64 samples per cycle
  • \n
  • Programmable storage rates from 125ms to 1 per day
  • \n
  • 3 user selectable storage modes
  • \n
  • Stores up to 240,000 measurements in non-volatile memory
  • \n
  • Powered by standard Alkaline batteries
  • \n
  • Lightweight, compact, fits anywhere
  • \n
  • 5 LED indicators quickly and clearly display logger status
  • \n
  • Includes DataView ® software for data storage, real-time waveform display, analysis and report generation
  • \n
  • Isolated USB communication
  • \n
  • 600V CAT IV; 1000V CAT III
  • \n
\n
Applications\n
    \n
  • Split phase load monitoring
  • \n
  • Neutral and ground current monitoring
  • \n
  • Intermittent problem detection
  • \n
  • Harmonic current monitoring using DataView ® software
  • \n
  • Machine load monitoring
  • \n
\n
", "catalogId": 287614, "id": 10226923, "name": "AEMC - ML912 - 2-Channel, TRMS, MiniFlex®; 100/1000AAC", "url": "/Products/data-loggers/current-loggers/aemc-ml912", "title": "", "smallImage": "/_assets/images/product/ml9123.jpg", "smallImageUrl": "/_assets/images/product/ml9123.jpg", "largeImage": "/_assets/images/product/ml9123.jpg", "largeImageUrl": "/_assets/images/product/ml9123.jpg", "releaseDate": "2016-10-04T00:00:00", "releaseDate_raw": "2016-10-03T23:00:00", "expiryDate": "9999-01-01T00:00:00", "expiryDate_raw": "9999-01-01T00:00:00", "productCode": "2126-37", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-ml912" }, { "description": "
\n

The Simple Logger® II (Bluetooth Edition) Model ML914 is a 4-channel AC current recording device powered by alkaline batteries and includes\n four integral 6\" MiniFlex® flexible current probes. The ML914 incorporates two user selectable measurement ranges of 100 and 1000 Amps.\n Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed around the nominal line frequency\n (50 or 60Hz). Harmonic measurements are calculated from these 64 samples and are only available from the Simple Logger® II Control Panel\n within the DataView®software.

\n

The Simple Logger® II stores TRMS at user programmable rates of up to eight times per second. TRMS calculations are performed on a single\n line cycle. The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer\n using DataView® software.

\n

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time\n information Bluetooth communication provides for the transfer of data from the instrument's internal memory to the computer for analysis.

\n \n \n \n \n \n \n \n \n \n
Features\n
    \n
  • User selectable storage modes
  • \n
  • Up to 180 days of operation from standard alkaline batteries
  • \n
  • Stores up to 1,000,000 measurements
  • \n
  • Wireless Bluetooth data communication (Bluetooth Module included)
  • \n
  • Includes FREE DataView® software for data storage, real-time waveform display, analysis & report generation
  • \n
  • User selectable ranges up to 1000A per channel
  • \n
  • User programmable recording modes: Start/Stop, FIFO, Extended Recording Mode (XRM™) and Alarm Recording
  • \n
  • EN61010-1; EN61010-2-32; 600V CAT IV, 1000V CAT III; Protection Degree IP50 (cover closed)
  • \n
\n
Applications\n
    \n
  • Single/split phase and 3 phase monitoring
  • \n
  • Neutral and ground current monitoring
  • \n
  • Intermittent problem detection
  • \n
  • Harmonic current monitoring using DataView® software
  • \n
  • Machine load monitoring
  • \n
  • Fault current detection
  • \n
  • Load profiling
  • \n
\n
\n
\n
", "catalogId": 287614, "id": 10226924, "name": "AEMC - ML914 - Current logger 4-Channel, TRMS, Bluetooth, MiniFlex® 100/1000AAC", "url": "/Products/data-loggers/current-loggers/aemc-ml914", "title": "", "smallImage": "/_assets/images/product/ml9149.jpg", "smallImageUrl": "/_assets/images/product/ml9149.jpg", "largeImage": "/_assets/images/product/ml9149.jpg", "largeImageUrl": "/_assets/images/product/ml9149.jpg", "releaseDate": "2016-10-04T00:00:00", "releaseDate_raw": "2016-10-03T23:00:00", "expiryDate": "9999-01-01T00:00:00", "expiryDate_raw": "9999-01-01T00:00:00", "productCode": "2126-4", "inStock": null, "onOrder": 0, "reorder": null, "minUnits": null, "maxUnits": null, "unitType": "", "tags": "", "custom1": "", "custom2": "", "custom3": "", "custom4": "", "isOnSale": false, "countryCode": "AU", "currencyFormat": "$", "countryCurrencyFormat": "AUD", "retailPrice": null, "salePrice": null, "wholesalePrice": null, "discountPrice": null, "totalDiscountPrice": null, "totalPrice": null, "tax": null, "taxCode": null, "taxRate": null, "urlWithHost": "http://www.pacifictest.com.au/Products/data-loggers/current-loggers/aemc-ml914" } ] }, "allCatalogs": { "moduleName": "catalogueselect", "moduleDescriptor": { "templatePath": null, "parameters": "parentId=\"-1\",collection=\"allCatalogs\",template=\"\"", "apiEndpoint": "/api/v3/catalogueselect", "objectType": -1, "objectId": -1, "adminUrl": "" }, "items": [ { "id": 287584, "name": "Products", "items": [ { "id": 287642, "name": "Accessories", "items": [ { "id": 287643, "name": "Instrument Cases & Bags" }, { "id": 287658, "name": "Test Leads & Probes" } ] }, { "id": 294863, "name": "Automation Relays", "items": [ { "id": 294864, "name": "Enerdis Function Relays" }, { "id": 294865, "name": "Enerdis Instantaneous Relays" }, { "id": 294866, "name": "Enerdis Time-delay Relays" } ] }, { "id": 287650, "name": "Battery Testers" }, { "id": 287616, "name": "Cable Testers" }, { "id": 287651, "name": "Circuit Breaker & Coil Analysers", "items": [ { "id": 287652, "name": "Circuit Breaker Analysers" }, { "id": 287657, "name": "Circuit Breaker Coil Analysers" } ] }, { "id": 287596, "name": "Clamp Meters", "items": [ { "id": 287600, "name": "AC Clamp Meters" }, { "id": 287597, "name": "AC-DC Clamp Meters" }, { "id": 287598, "name": "Power Clamps" } ] }, { "id": 287624, "name": "CLEARANCE PRODUCTS (Includes GST & Shipping)" }, { "id": 287667, "name": "Corona (UV) Cameras" }, { "id": 287591, "name": "Current Probes", "items": [ { "id": 287593, "name": "AC Current Probes" }, { "id": 287636, "name": "AC Oscilloscope Probes" }, { "id": 287628, "name": "AC-DC Current Probes" }, { "id": 287637, "name": "AC-DC Oscilloscope Probes" }, { "id": 287592, "name": "Flexible AC Current Probes" } ] }, { "id": 287613, "name": "Data Loggers", "items": [ { "id": 287634, "name": "Current and Voltage Loggers" }, { "id": 287614, "name": "Current Loggers" }, { "id": 287633, "name": "Event Loggers" }, { "id": 287635, "name": "Temperature and Humidity Loggers" }, { "id": 287632, "name": "Voltage Loggers" } ] }, { "id": 287646, "name": "Decade Resistance Boxes" }, { "id": 287594, "name": "Earth Testers", "items": [ { "id": 304598, "name": "2 Pole Earth Testers" }, { "id": 287599, "name": "3 & 4 Pole Earth Testers" }, { "id": 287595, "name": "Clamp On Earth Testers" }, { "id": 287607, "name": "Multifunction Earth Testers" }, { "id": 287627, "name": "Options & Accessories" }, { "id": 287660, "name": "Soil Resistivity Testers" }, { "id": 298086, "name": "Tower Testers" } ] }, { "id": 287617, "name": "Environmental Instruments", "items": [ { "id": 294747, "name": "Air Quality Meters" }, { "id": 295120, "name": "Electromagnetic Field Testers" }, { "id": 287618, "name": "Light Meters" }, { "id": 287619, "name": "Sound Level Meters" } ] }, { "id": 296982, "name": "Hard Resin IP67 Water & Dustproof Cases" }, { "id": 299690, "name": "High Current Measurement Systems" }, { "id": 287659, "name": "High Voltage Testers", "items": [ { "id": 299684, "name": "High Voltage Detectors" }, { "id": 299683, "name": "High Voltage Indicators" }, { "id": 299685, "name": "High Voltage Phasing Sticks" } ] }, { "id": 287585, "name": "Insulation Testers", "items": [ { "id": 287586, "name": "Insulation Testers - Up to 1000V" }, { "id": 287601, "name": "Insulation Testers - 2500V & 5000V" }, { "id": 287608, "name": "Insulation Testers - 10kV-15kV" }, { "id": 287587, "name": "15kV Test Leads" }, { "id": 287588, "name": "5kV Test Leads" } ] }, { "id": 287678, "name": "Loop Impedance Meters" }, { "id": 295867, "name": "Meter Site Tester" }, { "id": 287674, "name": "Multifunction Installation Testers" }, { "id": 287602, "name": "Multimeters", "items": [ { "id": 287603, "name": "4-Digit Multimeters" }, { "id": 287625, "name": "5-Digit Multimeters" }, { "id": 287638, "name": "6-Digit Multimeters" }, { "id": 295876, "name": "Analog Multimeters" }, { "id": 287639, "name": "Intrinsically Safe Multimeters" }, { "id": 287641, "name": "Multimeter Accessories" } ] }, { "id": 287604, "name": "Ohmmeters", "items": [ { "id": 287644, "name": "Intrinsically Safe Ohmmeters" }, { "id": 287605, "name": "Micro-Ohmmeters", "items": [ { "id": 287606, "name": "10Amp Micro-ohmmeters" }, { "id": 287654, "name": "High Current Micro-ohmmeters" } ] }, { "id": 287647, "name": "Milliohmmeters" }, { "id": 287655, "name": "Motor Winding Resistance Ohmmeters" }, { "id": 287629, "name": "Ohmmeter Leads", "items": [ { "id": 287630, "name": "Kelvin Clip Leads" }, { "id": 287631, "name": "Kelvin Spike Leads" } ] }, { "id": 287656, "name": "Transformer Ohmmeters" } ] }, { "id": 287649, "name": "Oil Testers" }, { "id": 287640, "name": "Oscilloscopes" }, { "id": 304648, "name": "Partial Discharge Detection" }, { "id": 294689, "name": "PAT Testers" }, { "id": 287668, "name": "Phase Angle Meters" }, { "id": 287609, "name": "Phase Rotation Indicators" }, { "id": 287665, "name": "Phase Sensitive Multimeters" }, { "id": 287673, "name": "Pipe & Cable Locators" }, { "id": 287662, "name": "Power Amplifiers" }, { "id": 287589, "name": "Power Analysers", "items": [ { "id": 287590, "name": "Accessories" }, { "id": 287663, "name": "Mains Powered" }, { "id": 295103, "name": "Permanent Monitoring" }, { "id": 287610, "name": "Portable (Battery Powered)", "items": [ { "id": 287611, "name": "Single Phase" }, { "id": 287612, "name": "Three-Phase" } ] } ] }, { "id": 287645, "name": "Power Cable Identification" }, { "id": 287653, "name": "Power Supplies" }, { "id": 287626, "name": "Ratiometers" }, { "id": 287677, "name": "RCD Testers" }, { "id": 287648, "name": "Resistance Standards" }, { "id": 287672, "name": "Rogowski Coils" }, { "id": 295813, "name": "Safety and HiPot Testers" }, { "id": 287666, "name": "Selective Level Meters" }, { "id": 287664, "name": "Sweep Frequency Response Analysers" }, { "id": 287615, "name": "Tachometers" }, { "id": 294743, "name": "Thermal Imagers" }, { "id": 287620, "name": "Thermometers", "items": [ { "id": 287623, "name": "Infrared Thermometers" }, { "id": 287622, "name": "Thermocouple Thermometers" }, { "id": 287621, "name": "Thermo-Hygrometers" } ] }, { "id": 287661, "name": "Ultrasonic Detectors" }, { "id": 287669, "name": "Voltage Testers" } ] } ], "params": { "parentId": "-1", "collection": "allCatalogs", "template": "" } }, "theCatalog": { "moduleName": "cataloguelistdump", "moduleDescriptor": { "templatePath": null, "parameters": "catalogId=\"287584\",collection=\"theCatalog\",template=\"\"", "apiEndpoint": "/api/v3/cataloguelistdump", "objectType": 75, "objectId": -1, "adminUrl": "" }, "items": [ { "name": "Accessories", "url": "/Products/Accessories" }, { "name": "Automation Relays", "url": "/Products/automation-relays" }, { "name": "Battery Testers", "url": "/Products/battery-testers" }, { "name": "Cable Testers", "url": "/Products/cable-testers" }, { "name": "Circuit Breaker & Coil Analysers", "url": "/Products/circuit-breaker-coil-analysers" }, { "name": "Clamp Meters", "url": "/Products/clamp-meters" }, { "name": "CLEARANCE PRODUCTS (Includes GST & Shipping)", "url": "/Products/clearance-products" }, { "name": "Corona (UV) Cameras", "url": "/Products/corona-uv-cameras" }, { "name": "Current Probes", "url": "/Products/current-probes" }, { "name": "Data Loggers", "url": "/Products/data-loggers" }, { "name": "Decade Resistance Boxes", "url": "/Products/decade-resistance-boxes" }, { "name": "Earth Testers", "url": "/Products/earth-testers" }, { "name": "Environmental Instruments", "url": "/Products/environmental-instruments" }, { "name": "Hard Resin IP67 Water & Dustproof Cases", "url": "/Products/hard-reson-ip67-water-dustproof-cases" }, { "name": "High Current Measurement Systems", "url": "/Products/high-current-measurement-systems" }, { "name": "High Voltage Testers", "url": "/Products/high-voltage-testers" }, { "name": "Insulation Testers", "url": "/Products/insulation-testers" }, { "name": "Loop Impedance Meters", "url": "/Products/loop-impedance-meters" }, { "name": "Meter Site Tester", "url": "/Products/meter-site-testing" }, { "name": "Multifunction Installation Testers", "url": "/Products/installation-testers" }, { "name": "Multimeters", "url": "/Products/Multimeters" }, { "name": "Ohmmeters", "url": "/Products/Ohmmeters" }, { "name": "Oil Testers", "url": "/Products/oil-testers" }, { "name": "Oscilloscopes", "url": "/Products/Oscilloscopes" }, { "name": "Partial Discharge Detection", "url": "/Products/partial-discharge-detection" }, { "name": "PAT Testers", "url": "/Products/tag-testers" }, { "name": "Phase Angle Meters", "url": "/Products/phase-angle-meters" }, { "name": "Phase Rotation Indicators", "url": "/Products/phase-rotation-indicators" }, { "name": "Phase Sensitive Multimeters", "url": "/Products/phase-sensitive-multimeters" }, { "name": "Pipe & Cable Locators", "url": "/Products/pipe-cable-locators" }, { "name": "Power Amplifiers", "url": "/Products/power-amplifiers" }, { "name": "Power Analysers", "url": "/Products/power-analysers" }, { "name": "Power Cable Identification", "url": "/Products/power-cable-identification" }, { "name": "Power Supplies", "url": "/Products/power-supplies" }, { "name": "Ratiometers", "url": "/Products/Ratiometers" }, { "name": "RCD Testers", "url": "/Products/rcd-testers" }, { "name": "Resistance Standards", "url": "/Products/resistance-standards" }, { "name": "Rogowski Coils", "url": "/Products/rogowski-coils" }, { "name": "Safety and HiPot Testers", "url": "/Products/safety-testers" }, { "name": "Selective Level Meters", "url": "/Products/selective-level-meters" }, { "name": "Sweep Frequency Response Analysers", "url": "/Products/sweep-frequency-response-analysers" }, { "name": "Tachometers", "url": "/Products/Tachometers" }, { "name": "Thermal Imagers", "url": "/Products/thermal-imagers" }, { "name": "Thermometers", "url": "/Products/Thermometers" }, { "name": "Ultrasonic Detectors", "url": "/Products/ultrasonic-detectors" }, { "name": "Voltage Testers", "url": "/Products/voltage-testers" } ], "params": { "catalogId": "287584", "collection": "theCatalog", "template": "" } } }